Switch is a two-channel switch with two switching methods: sequential and gated.
Controls
- Digital Ins: A clock at Input 1 switches the A/C output between CV1 and CV2. A gate signal at Input 2 switches the B/D output to CV2.
- CV Ins: CV1 and CV2
- Outputs: A/C is the sequentially-selected output, and B/D is the gated output. The sequential output alternates between CV1 and CV2, and the gated output is CV1 when digital input 2 is low, and CV2 when high.
Switch uses a Skyline display to indicate status of each channel. The indicator for each channel also specifies whether CV1 or CV2 is currently selected.
_Note: The Ornament and Crime's circuitry is not made for precision 1:1 reproduction of voltages. The outputs will not exactly match the inputs, so Switch is not suitable for pitch CV. This is inherent to the O_C's design and does not indicate poor calibration._
Switch is available in Hemisphere and Hemisphere Suite.