-- Implement a servo driver for the Tower Pro SG90
-- It uses a PWM signal as control mechanism.
-- Copyright Erik Zachrisson erik@zachrisson.info
-- Assumes 64kHz frequency i.e a period of 15.63 us
-- A max count of 1280 * 15.63 = 20 ms = 50 Hz
-- Spec states: 600-2400 µs pulse width
-- Base width is 32 * 15.63 = 0.5 ms
-- Each tick represents an increase of 15.53 us
-- 7 bits of resolution = 128 ticks
-- Max val is : 127 + 32 = 159
-- In time: 159 * 15.63 = 2485.17 us
--
-- According to forum:
-- Full range on the SG90 is: 2.4 mS (~90o) to 0.6mS (~270o) clockwise.
library ieee;
use ieee.std_logic_1164.all;
use ieee.std_logic_arith.all;
use ieee.std_logic_unsigned.all;
use work.Types.all;
entity servo_pwm is
generic (
ResW : positive := 7
);
port (
Clk : in bit1; -- Must be 64 kHz
RstN : in bit1;
--
Pos : in word(ResW-1 downto 0);
--
Servo : out bit1
);
end Servo_pwm;
architecture Behavioral of Servo_pwm is
constant MaxCnt : positive := 1279;
constant MaxCntW : positive := bits(MaxCnt);
-- Counter, from 0 to 1279.
signal Cnt_D : word(MaxCntW-1 downto 0);
-- Temporal signal used to generate the PWM pulse.
signal pwmi : word(ResW downto 0);
begin
-- Minimum value should be 0.5ms.
pwmi <= ('0' & Pos) + 32;
-- Counter process, from 0 to 1279.
counter : process (RstN, Clk)
begin
if (RstN = '0') then
-- FIXME: Is reset necessary? Probably not as it will correct itself very
-- early after initialization
Cnt_D <= (others => '0');
elsif rising_edge(Clk) then
if Cnt_D = MaxCnt then
Cnt_D <= (others => '0');
else
Cnt_D <= Cnt_D + 1;
end if;
end if;
end process;
-- Output signal for the Servomotor.
Servo <= '1' when Cnt_D < pwmi else '0';
end Behavioral;