<?xml version="1.0" encoding="UTF-8"?>
<!-- MIT License
Copyright (c) 2018 IPSO.
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE. -->
<LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M.xsd">
<Object ObjectType="MODefinition">
<Name>Power Control</Name>
<Description1>Description: This Object is used to control a power source, such as a Smart Plug. It allows a power relay to be turned on or off and its dimmer setting to be control as a % between 0 and 100.</Description1>
<ObjectID>3312</ObjectID>
<ObjectURN>urn:oma:lwm2m:ext:3312</ObjectURN>
<LWM2MVersion>1.0</LWM2MVersion>
<ObjectVersion>1.0</ObjectVersion>
<MultipleInstances>Multiple</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Resources>
<Item ID="5850">
<Name>On/Off</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Mandatory</Mandatory>
<Type>Boolean</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>This resource represents a power relay, which can be controlled, the setting of which is a Boolean value (1,0) where 1 is on and 0 is off.</Description>
</Item>
<Item ID="5851">
<Name>Dimmer</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Integer</Type>
<RangeEnumeration>0-100</RangeEnumeration>
<Units>%</Units>
<Description>This resource represents a power dimmer setting, which has an Integer value between 0 and 100 as a percentage.</Description>
</Item>
<Item ID="5852">
<Name>On time</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Integer</Type>
<RangeEnumeration></RangeEnumeration>
<Units>s</Units>
<Description>The time in seconds that the power relay has been on. Writing a value of 0 resets the counter.</Description>
</Item>
<Item ID="5805">
<Name>Cumulative active power</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units>Wh</Units>
<Description>The total power in Wh that has been used by the load.</Description>
</Item>
<Item ID="5820">
<Name>Power factor</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>The power factor of the load.</Description>
</Item>
<Item ID="5750">
<Name>Application Type</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>String</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>The application type of the sensor or actuator as a string, for instance, “Air Pressure”</Description>
</Item>
</Resources>
<Description2></Description2>
</Object>
</LWM2M>