forked from OpenMobileAlliance/lwm2m-registry
-
Notifications
You must be signed in to change notification settings - Fork 0
/
3320.xml
118 lines (112 loc) · 6.06 KB
/
3320.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
<?xml version="1.0" encoding="UTF-8"?>
<!-- MIT License
Copyright (c) 2018 IPSO.
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE. -->
<LWM2M xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M.xsd">
<Object ObjectType="MODefinition">
<Name>Percentage</Name>
<Description1>This IPSO object should can be used to report measurements relative to a 0-100% scale. For example it could be used to measure the level of a liquid in a vessel or container in units of %.
</Description1>
<ObjectID>3320</ObjectID>
<ObjectURN>urn:oma:lwm2m:ext:3320</ObjectURN>
<LWM2MVersion>1.0</LWM2MVersion>
<ObjectVersion>1.0</ObjectVersion>
<MultipleInstances>Multiple</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Resources>
<Item ID="5700">
<Name>Sensor Value</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Mandatory</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Last or Current Measured Value from the Sensor</Description>
</Item>
<Item ID="5701">
<Name>Sensor Units</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>String</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Measurement Units Definition e.g. “Cel” for Temperature in Celsius</Description>
</Item>
<Item ID="5601">
<Name>Min Measured Value</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>The minimum value measured by the sensor since power ON or reset</Description>
</Item>
<Item ID="5602">
<Name>Max Measured Value</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>The maximum value measured by the sensor since power ON or reset</Description>
</Item>
<Item ID="5603">
<Name>Min Range Value</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>The minimum value that can be measured by the sensor</Description>
</Item>
<Item ID="5604">
<Name>Max Range Value</Name>
<Operations>R</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>The maximum value that can be measured by the sensor</Description>
</Item>
<Item ID="5605">
<Name>Reset Min and Max Measured Values</Name>
<Operations>E</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type></Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Reset the Min and Max Measured Values to Current Value</Description>
</Item>
<Item ID="5821">
<Name>Current Calibration</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>Float</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>Read or Write the current calibration coefficient</Description>
</Item>
<Item ID="5750">
<Name>Application Type</Name>
<Operations>RW</Operations>
<MultipleInstances>Single</MultipleInstances>
<Mandatory>Optional</Mandatory>
<Type>String</Type>
<RangeEnumeration></RangeEnumeration>
<Units></Units>
<Description>The application type of the sensor or actuator as a string depending on the use case</Description>
</Item>
</Resources>
<Description2></Description2>
</Object>
</LWM2M>