diff --git a/docs/release_notes.rst b/docs/release_notes.rst index 999f1fb9..10f9af88 100644 --- a/docs/release_notes.rst +++ b/docs/release_notes.rst @@ -7,6 +7,8 @@ Release Notes * added fuel costs for bioethanol crops, rape seed, and manure from JRC ENSPRESO +* added fuel costs for fuelwood from JRC ENSPRESO + Technology-Data 0.9.0 (12 May 2024) =================================== * add methanol-to-kerosene cost data (https://github.com/PyPSA/technology-data/pull/136) diff --git a/inputs/manual_input.csv b/inputs/manual_input.csv index ed3af3ff..8bc8ffe9 100644 --- a/inputs/manual_input.csv +++ b/inputs/manual_input.csv @@ -378,4 +378,8 @@ biodiesel crops,fuel,2050,115.905289026151,EUR/MWhth,2010,"JRC ENSPRESO ca avg f biogas manure,fuel,2020,17.3705908155502,EUR/MWhth,2010,"JRC ENSPRESO ca avg for MINBIOGAS1 (manure), ENS_BaU_GFTM", biogas manure,fuel,2030,17.4674555553638,EUR/MWhth,2010,"JRC ENSPRESO ca avg for MINBIOGAS1 (manure), ENS_BaU_GFTM", biogas manure,fuel,2040,17.4767827669554,EUR/MWhth,2010,"JRC ENSPRESO ca avg for MINBIOGAS1 (manure), ENS_BaU_GFTM", -biogas manure,fuel,2050,17.5404377813252,EUR/MWhth,2010,"JRC ENSPRESO ca avg for MINBIOGAS1 (manure), ENS_BaU_GFTM", \ No newline at end of file +biogas manure,fuel,2050,17.5404377813252,EUR/MWhth,2010,"JRC ENSPRESO ca avg for MINBIOGAS1 (manure), ENS_BaU_GFTM", +fuelwood,fuel,2020,14.066770723441,EUR/MWhth,2010,"JRC ENSPRESO ca avg for MINBIOWOO (FuelwoodRW), ENS_BaU_GFTM", +fuelwood,fuel,2030,12.767964974663,EUR/MWhth,2010,"JRC ENSPRESO ca avg for MINBIOWOO (FuelwoodRW), ENS_BaU_GFTM", +fuelwood,fuel,2040,11.5992033141145,EUR/MWhth,2010,"JRC ENSPRESO ca avg for MINBIOWOO (FuelwoodRW), ENS_BaU_GFTM", +fuelwood,fuel,2050,10.5474097062402,EUR/MWhth,2010,"JRC ENSPRESO ca avg for MINBIOWOO (FuelwoodRW), ENS_BaU_GFTM", \ No newline at end of file diff --git a/outputs/costs_2020.csv b/outputs/costs_2020.csv index 73aba527..e467beef 100644 --- a/outputs/costs_2020.csv +++ b/outputs/costs_2020.csv @@ -845,6 +845,7 @@ fuel cell,c_b,1.25,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_ fuel cell,efficiency,0.5,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","12 LT-PEMFC CHP: Electricity efficiency, annual average",2015.0 fuel cell,investment,1375.6881,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Nominal investment,2015.0 fuel cell,lifetime,10.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Technical lifetime,2015.0 +fuelwood,fuel,15.9997,EUR/MWhth,"JRC ENSPRESO ca avg for MINBIOWOO (FuelwoodRW), ENS_BaU_GFTM",,2010.0 gas,CO2 intensity,0.198,tCO2/MWh_th,Stoichiometric calculation with 50 GJ/t CH4,, gas,fuel,24.568,EUR/MWh_th,"DIW (2013): Current and propsective costs of electricity generation until 2050, http://hdl.handle.net/10419/80348 , pg. 80 text below figure 10, accessed: 2023-12-14.",Based on IEA 2011 data.,2010.0 gas boiler steam,FOM,3.6667,%/year,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",311.1c Steam boiler Gas: Fixed O&M,2019.0 diff --git a/outputs/costs_2025.csv b/outputs/costs_2025.csv index a59b9970..88cefdc4 100644 --- a/outputs/costs_2025.csv +++ b/outputs/costs_2025.csv @@ -845,6 +845,7 @@ fuel cell,c_b,1.25,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_ fuel cell,efficiency,0.5,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","12 LT-PEMFC CHP: Electricity efficiency, annual average",2015.0 fuel cell,investment,1269.866,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Nominal investment,2015.0 fuel cell,lifetime,10.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Technical lifetime,2015.0 +fuelwood,fuel,15.261,EUR/MWhth,"JRC ENSPRESO ca avg for MINBIOWOO (FuelwoodRW), ENS_BaU_GFTM",,2010.0 gas,CO2 intensity,0.198,tCO2/MWh_th,Stoichiometric calculation with 50 GJ/t CH4,, gas,fuel,24.568,EUR/MWh_th,"DIW (2013): Current and propsective costs of electricity generation until 2050, http://hdl.handle.net/10419/80348 , pg. 80 text below figure 10, accessed: 2023-12-14.",Based on IEA 2011 data.,2010.0 gas boiler steam,FOM,3.9,%/year,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",311.1c Steam boiler Gas: Fixed O&M,2019.0 diff --git a/outputs/costs_2030.csv b/outputs/costs_2030.csv index 9aff398a..e9ec0d4e 100644 --- a/outputs/costs_2030.csv +++ b/outputs/costs_2030.csv @@ -845,6 +845,7 @@ fuel cell,c_b,1.25,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_ fuel cell,efficiency,0.5,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","12 LT-PEMFC CHP: Electricity efficiency, annual average",2015.0 fuel cell,investment,1164.0438,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Nominal investment,2015.0 fuel cell,lifetime,10.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Technical lifetime,2015.0 +fuelwood,fuel,14.5224,EUR/MWhth,"JRC ENSPRESO ca avg for MINBIOWOO (FuelwoodRW), ENS_BaU_GFTM",,2010.0 gas,CO2 intensity,0.198,tCO2/MWh_th,Stoichiometric calculation with 50 GJ/t CH4,, gas,fuel,24.568,EUR/MWh_th,"DIW (2013): Current and propsective costs of electricity generation until 2050, http://hdl.handle.net/10419/80348 , pg. 80 text below figure 10, accessed: 2023-12-14.",Based on IEA 2011 data.,2010.0 gas boiler steam,FOM,4.18,%/year,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",311.1c Steam boiler Gas: Fixed O&M,2019.0 diff --git a/outputs/costs_2035.csv b/outputs/costs_2035.csv index 7cb7d407..4bfe4383 100644 --- a/outputs/costs_2035.csv +++ b/outputs/costs_2035.csv @@ -845,6 +845,7 @@ fuel cell,c_b,1.25,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_ fuel cell,efficiency,0.5,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","12 LT-PEMFC CHP: Electricity efficiency, annual average",2015.0 fuel cell,investment,1084.6772,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Nominal investment,2015.0 fuel cell,lifetime,10.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Technical lifetime,2015.0 +fuelwood,fuel,13.8577,EUR/MWhth,"JRC ENSPRESO ca avg for MINBIOWOO (FuelwoodRW), ENS_BaU_GFTM",,2010.0 gas,CO2 intensity,0.198,tCO2/MWh_th,Stoichiometric calculation with 50 GJ/t CH4,, gas,fuel,24.568,EUR/MWh_th,"DIW (2013): Current and propsective costs of electricity generation until 2050, http://hdl.handle.net/10419/80348 , pg. 80 text below figure 10, accessed: 2023-12-14.",Based on IEA 2011 data.,2010.0 gas boiler steam,FOM,4.07,%/year,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",311.1c Steam boiler Gas: Fixed O&M,2019.0 diff --git a/outputs/costs_2040.csv b/outputs/costs_2040.csv index 4c25f5b0..df297e74 100644 --- a/outputs/costs_2040.csv +++ b/outputs/costs_2040.csv @@ -845,6 +845,7 @@ fuel cell,c_b,1.25,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_ fuel cell,efficiency,0.5,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","12 LT-PEMFC CHP: Electricity efficiency, annual average",2015.0 fuel cell,investment,1005.3105,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Nominal investment,2015.0 fuel cell,lifetime,10.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Technical lifetime,2015.0 +fuelwood,fuel,13.193,EUR/MWhth,"JRC ENSPRESO ca avg for MINBIOWOO (FuelwoodRW), ENS_BaU_GFTM",,2010.0 gas,CO2 intensity,0.198,tCO2/MWh_th,Stoichiometric calculation with 50 GJ/t CH4,, gas,fuel,24.568,EUR/MWh_th,"DIW (2013): Current and propsective costs of electricity generation until 2050, http://hdl.handle.net/10419/80348 , pg. 80 text below figure 10, accessed: 2023-12-14.",Based on IEA 2011 data.,2010.0 gas boiler steam,FOM,3.96,%/year,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",311.1c Steam boiler Gas: Fixed O&M,2019.0 diff --git a/outputs/costs_2045.csv b/outputs/costs_2045.csv index abcb2171..bf04bcbd 100644 --- a/outputs/costs_2045.csv +++ b/outputs/costs_2045.csv @@ -845,6 +845,7 @@ fuel cell,c_b,1.25,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_ fuel cell,efficiency,0.5,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","12 LT-PEMFC CHP: Electricity efficiency, annual average",2015.0 fuel cell,investment,925.9439,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Nominal investment,2015.0 fuel cell,lifetime,10.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Technical lifetime,2015.0 +fuelwood,fuel,12.5949,EUR/MWhth,"JRC ENSPRESO ca avg for MINBIOWOO (FuelwoodRW), ENS_BaU_GFTM",,2010.0 gas,CO2 intensity,0.198,tCO2/MWh_th,Stoichiometric calculation with 50 GJ/t CH4,, gas,fuel,24.568,EUR/MWh_th,"DIW (2013): Current and propsective costs of electricity generation until 2050, http://hdl.handle.net/10419/80348 , pg. 80 text below figure 10, accessed: 2023-12-14.",Based on IEA 2011 data.,2010.0 gas boiler steam,FOM,3.85,%/year,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",311.1c Steam boiler Gas: Fixed O&M,2019.0 diff --git a/outputs/costs_2050.csv b/outputs/costs_2050.csv index f4e63d9c..f968b90e 100644 --- a/outputs/costs_2050.csv +++ b/outputs/costs_2050.csv @@ -845,6 +845,7 @@ fuel cell,c_b,1.25,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_ fuel cell,efficiency,0.5,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","12 LT-PEMFC CHP: Electricity efficiency, annual average",2015.0 fuel cell,investment,846.5773,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Nominal investment,2015.0 fuel cell,lifetime,10.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",12 LT-PEMFC CHP: Technical lifetime,2015.0 +fuelwood,fuel,11.9967,EUR/MWhth,"JRC ENSPRESO ca avg for MINBIOWOO (FuelwoodRW), ENS_BaU_GFTM",,2010.0 gas,CO2 intensity,0.198,tCO2/MWh_th,Stoichiometric calculation with 50 GJ/t CH4,, gas,fuel,24.568,EUR/MWh_th,"DIW (2013): Current and propsective costs of electricity generation until 2050, http://hdl.handle.net/10419/80348 , pg. 80 text below figure 10, accessed: 2023-12-14.",Based on IEA 2011 data.,2010.0 gas boiler steam,FOM,3.74,%/year,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",311.1c Steam boiler Gas: Fixed O&M,2019.0