forked from amadvance/snapraid
-
Notifications
You must be signed in to change notification settings - Fork 0
/
snapraid.conf.example.windows
108 lines (95 loc) · 3.98 KB
/
snapraid.conf.example.windows
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
# Example configuration for snapraid for Windows
# Defines the file to use as parity storage
# It must NOT be in a data disk
# Format: "parity FILE [,FILE] ..."
parity E:\snapraid.parity
# Defines the files to use as additional parity storage.
# If specified, they enable the multiple failures protection
# from two to six level of parity.
# To enable, uncomment one parity file for each level of extra
# protection required. Start from 2-parity, and follow in order.
# It must NOT be in a data disk
# Format: "X-parity FILE [,FILE] ..."
#2-parity F:\snapraid.2-parity
#3-parity G:\snapraid.3-parity
#4-parity H:\snapraid.4-parity
#5-parity I:\snapraid.5-parity
#6-parity J:\snapraid.6-parity
# Defines the files to use as content list
# You can use multiple specification to store more copies
# You must have least one copy for each parity file plus one. Some more don't hurt
# They can be in the disks used for data, parity or boot,
# but each file must be in a different disk
# Format: "content FILE"
content C:\snapraid\snapraid.content
content K:\array\snapraid.content
content L:\array\snapraid.content
# Defines the data disks to use
# The name and mount point association is relevant for parity, do not change it
# WARNING: Adding here your boot C:\ disk is NOT a good idea!
# SnapRAID is better suited for files that rarely changes!
# Format: "data DISK_NAME DISK_MOUNT_POINT"
data d1 K:\array\
data d2 L:\array\
data d3 M:\array\
# Excludes hidden files and directories (uncomment to enable).
#nohidden
# Defines files and directories to exclude
# Remember that all the paths are relative at the mount points
# Format: "exclude FILE"
# Format: "exclude DIR\"
# Format: "exclude \PATH\FILE"
# Format: "exclude \PATH\DIR\"
exclude *.unrecoverable
exclude Thumbs.db
exclude \$RECYCLE.BIN
exclude \System Volume Information
exclude \Program Files\
exclude \Program Files (x86)\
exclude \Windows\
# Defines the block size in kibi bytes (1024 bytes) (uncomment to enable).
# WARNING: Changing this value is for experts only!
# Default value is 256 -> 256 kibi bytes -> 262144 bytes
# Format: "blocksize SIZE_IN_KiB"
#blocksize 256
# Defines the hash size in bytes (uncomment to enable).
# WARNING: Changing this value is for experts only!
# Default value is 16 -> 128 bits
# Format: "hashsize SIZE_IN_BYTES"
#hashsize 16
# Automatically save the state when syncing after the specified amount
# of GB processed (uncomment to enable).
# This option is useful to avoid to restart from scratch long 'sync'
# commands interrupted by a machine crash.
# It also improves the recovering if a disk break during a 'sync'.
# Default value is 0, meaning disabled.
# Format: "autosave SIZE_IN_GB"
#autosave 500
# Defines the pooling directory where the virtual view of the disk
# array is created using the "pool" command (uncomment to enable).
# The files are not really copied here, but just linked using
# symbolic links.
# This directory must be outside the array.
# Format: "pool DIR"
#pool C:\pool
# Defines the Windows UNC path required to access disks from the pooling
# directory when shared in the network.
# If present (uncomment to enable), the symbolic links created in the
# pool virtual view, instead of using local paths, are created using the
# specified UNC path, adding the disk names and file path.
# This allows to share the pool directory in the network.
# See the manual page for more details.
#
# Format: "share UNC_DIR"
#share \\server
# Defines a custom smartctl command to obtain the SMART attributes
# for each disk. This may be required for RAID controllers and for
# some USB disk that cannot be autodetected.
# In the specified options, the "%s" string is replaced by the device name.
# Refers at the smartmontools documentation about the possible options:
# RAID -> https://www.smartmontools.org/wiki/Supported_RAID-Controllers
# USB -> https://www.smartmontools.org/wiki/Supported_USB-Devices
#smartctl d1 -d sat %s
#smartctl d2 -d usbjmicron %s
#smartctl parity -d areca,1/1 /dev/arcmsr0
#smartctl 2-parity -d areca,2/1 /dev/arcmsr0