This document captures all of the changes that the BEP001 team are proposing to the BIDS specification.
Table of contents:
- Indexable metadata
- Acquisition metadata field
- Part metadata field
- Repetition time
- Symbolic links
- Suffix
- B1plus fieldmaps
- Repetition Time
- B1plus fieldmaps
- S0map
Change in /src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md
.
There are a lot of different additional metadata fields that may be needed for structural brain imaging.
In this change we added a field called indexable_metadata
to capture those changes.
The use is described in /src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md#indexable_metadata-index-key-value-pair
.
The keys can be pulled from the "Sequence specifics" table (/src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md#sequence-specifics
).
This table was updated to include metadata fields for MT sequences and to include metadata fields for any sequence with spoiling gradients.
The acq-<label>
key-value pair was added to capture a group of parametrically linked anatomical images.
This was updated in /src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md#acq-label-key-value-pair
.
Change in /src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md#part-magphase-keyvalue-pair
.
The part-<mag/phase>
key-value pair was added to distinguish the magnitude and phase parts of an acquisition.
We additionally recommend (but do not require) that phase images should be in radians and have a range of 0 (inclusive) to 2pi (not included).
Adjust the definition of RepetitionTime
in section 4.1.x Task (including resting state) imaging data and add two new fields to section 4.1.y Anatomy imaging data.
RepetitionTime
is currently defined very specifically as relating to functional imaging data.
However there are structural scans that collect multiple volumes during an acquisition.
Here we adjust the definition of RepetitionTime
in section 4.1.x and add RepetitionTimeExcitation
and RepetitionTimePreparation
as two additional terms for structural acquisitions that include multiple contrasts in 4.1.y.
Files in the derived folder can be symbolically linked to the main BIDS folder.
For example, a derived quantitative map derivatives/sub-01/anat/sub-01_R1.nii.gz
may be linked as sub-01/anat/sub-01_T1w.nii.gz
to be used as a standard structural image for functional MRI processing pipelines.
This change was made in /src/02-common-principles.md#symbolic-links
.
Whether a file is "derived" or "raw" depends on where you're starting from.
To give a specific example, some researchers will be working on creating quantitative maps, while others will want to use the map as an input file to a structural processing pipeline.
There is a possible natural cut off by saying that files in the BIDS specification are "raw" as they come off the scanner, and "derived" if offline processing has happened.
Unfortunately, it is not possible to harmonize datasets across different scanners when following this rule.
For example MP2RAGE images are sometimes used to construct _T1uni
-images and _T1map
s on the scanner system, but on some systems, this only happens post-hoc/"offline".
The original specification uses modality_label
at the end of each file name.
We have updated this to suffix
as there are multiple modalities that are not captured in the proposed options, and because the boundaries between "modalities" differ by domain specification.
This change was made in /src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md#anatomy-imaging-data
Extend the part on Fieldmaps
in 4.1.x Task (including resting state) imaging data by also allowing
for storing B1+ fieldmaps.
For some anatomical MRI acquisitions, especially when doing quantiative MRI (qMRI), B1+ fieldmaps can be useful to get better estimates of the underlying physical parameters (e.g., T1 in T1 maps obtained with MP2RAGE-sequence, see Marques et al., 2013).
Add a suffix _S0map
to store the intercept-parameter for when T2*-decay curves are fit, for example using a multi-echo Gradien-Recalled Echo (GRE)-sequence.
Change in /src/04-modality-specific-files/01-magnetic-resonance-imaging-data.md#suffix
.
Both structural and functional multi-echo sequences are becoming more and more common. By fitting an exponential T2*-model to such data, a S0-map
remains that contains contrast for proton density (PD) and B1+ and B1--effects. This can be useful for for example skull-stripping.