Note that electrode positions SHOULD NOT be added to this file, but to [`*_electrodes.tsv`](./03-electroencephalography.md#electrodes-description-_electrodestsv).
Furthermore, the entries in `*_electrodes.tsv` and `*_channels.tsv` do not have to match exactly,
as for example in the case of recording a single `EOG` channel from a bipolar referencing scheme
of two electrodes.
of two electrodes, or a data channel originating from an auxilliary, non-electrode device.
That is, in most cases `*_electrodes.tsv` will have more entries than `*_channels.tsv`.
See the examples for `*_channels.tsv` below, and for `*_electrodes.tsv` in
["Electrodes description"](./03-electroencephalography.md#electrodes-description-_electrodestsv).

The columns of the Channels description table stored in `*_channels.tsv` are:

Expand Down Expand Up @@ -252,14 +254,16 @@ Example of free-form text for field `description`

- n/a, stimulus, response, skin conductance, battery status

Example:
### Example `channels.tsv`

See also the corresponding [`electrodes.tsv` example](#example-electrodestsv).

```Text
name type units description status status_description
VEOG VEOG uV n/a good n/a
FDI EMG uV left first dorsal interosseous good n/a
Cz EEG uV n/a bad high frequency noise
UADC001 MISC n/a envelope of audio signal good n/a
name type units description reference status status_description
VEOG VEOG uV left eye VEOG-, VEOG+ good n/a
FDI EMG uV left first dorsal interosseous FDI-, FDI+ good n/a
Cz EEG uV n/a REF bad high frequency noise
UADC001 MISC n/a envelope of audio signal n/a good n/a
```

## Electrodes description (`*_electrodes.tsv`)
Expand Down Expand Up @@ -290,15 +294,19 @@ SHOULD be present:
| material | RECOMMENDED | Material of the electrode (for example, Tin, Ag/AgCl, Gold). |
| impedance | RECOMMENDED | Impedance of the electrode, units MUST be in `kOhm`. |

Example:
### Example `electrodes.tsv`

See also the corresponding [`electrodes.tsv` example](#example-channelstsv).

```Text
name x y z type material
A1 -0.0707 0.0000 -0.0707 clip-on Ag/AgCl
F3 -0.0567 0.0677 0.0469 cup Ag/AgCl
Fz 0.0000 0.0714 0.0699 cup Ag/AgCl
REF -0.0742 -0.0200 -0.0100 cup Ag/AgCl
GND 0.0742 -0.0200 -0.0100 cup Ag/AgCl
name x y z type material
VEOG+ n/a n/a n/a cup Ag/AgCL
VEOG- n/a n/a n/a cup Ag/AgCL
FDI+ n/a n/a n/a cup Ag/AgCL
FDI- n/a n/a n/a cup Ag/AgCL
GND -0.0707 0.0000 -0.0707 clip-on Ag/AgCl
Cz 0.0000 0.0714 0.0699 cup Ag/AgCl
REF -0.0742 -0.0200 -0.0100 cup Ag/AgCl
```

The [`acq-<label>`](../99-appendices/09-entities.md#acq) key/value pair can be used to indicate acquisition of the same data. For