Xiaomi Miot Serial Communication

Translated and converted to .md from Xiaomi IoT Developer Platform

Serial command interaction

Serial text commands are used to transfer commands between the hardware product MCU and the Xiaomi IoT module in the way of "repeat questions and answers". Regardless of whether the command is executed successfully or not, the corresponding result and error message will be returned:

  • ↑: Instruction, "uplink" information, refers to the hardware product sending instructions to the Xiaomi IoT platform through the Xiaomi IoT module, such as a sensor reporting the temperature attribute value to the Xiaomi IoT platform through the Xiaomi IoT module;
  • ↓: As a result, "downlink" information means that the Xiaomi IoT platform sends instructions to hardware products through the module. For example, the Xiaomi IoT platform sends instructions to the Xiaomi IoT module, and the Xiaomi IoT module receives the information and translates it into text instructions. After using the “get _ down” command to poll to obtain the text command and perform the corresponding operation, the MCU of the company calls the “result” response command to inform the small IoT meter module to complete the operation.

Precautions

  • All text commands, unless otherwise specified, use lowercase letters;
  • For each operation of the module, the MCU needs to use the corresponding serial port commands to communicate with the module through the serial port;
  • Serial command communication can transmit up to 512 bytes of data at a time, and the command carries no more than 64 parameters; but the MCU needs to support not less than 512 bytes of serial processing capabilities, and at the same time, for unrecognized commands, it needs to reply to errors;
  • It is recommended to use the "props" command to report the current attribute value when the detected attribute changes exceed a certain range, and high frequency reporting of normal attributes is not allowed;
  • When a set event (Event) occurs, the event is reported through the "event" command.

The developer needs to send the "get _ down" command to the Xiaomi IoT module in a polling manner (the time range is 100~200ms, the recommended cycle period is 200ms) , and receive the Xiaomi IoT module from the Xiaomi IoT platform and translate it Instruction If the Xiaomi IoT module replies "down none", use the "get_down" command to poll the module, otherwise, it needs to immediately reply to the command according to the obtained command and execute the corresponding action; After the MCU completes the execution of the instruction, it needs to call the "result" instruction to send the instruction execution result to the module; if the instruction received by the MCU is not supported in the instruction list or executes incorrectly, it needs to call the "error" instruction to send it to the module Error code and error description. If the Xiaomi IoT module has received the error code and error description, it will reply "ok".

Command Flow

illustrate

The MCU of the hardware product and the Xiaomi IoT module use the serial port command to interact. The serial port command can transmit up to 512 bytes of data at a time, and the parameters carried by the command do not exceed 64 bytes. Therefore, it is recommended that the MCU of the developer's hardware product supports not Less than 512 bytes of serial port processing capacity; Use attribute commands to report changed attributes. Do not report normal attributes with high frequency; when a set event (Event) occurs, developers can report the event through the event report command; If the MCU of the developer's hardware product cannot recognize the commands issued by the Xiaomi IoT module, the MCU of the hardware product must reply to the Xiaomi IoT module with an error.

Property report

"Property report" is a function used to report device status. In order to enable users to control hardware products through control terminals such as Mijia APP or Xiaoai Communication and realize functions such as "automation", developers must implement the "Attribute report" function, as follows Take "Temperature Sensor Reporting Temperature" as an example to introduce the process of implementing the attribute reporting function.

  1. The sensor detects that the current temperature is 26
  2. The sensor calls the attribute report command of the MIIO module, and reports the temperature attribute value to the cloud through the MIIO module
  3. The MIIO chip replied "ok", notifying that the result has been received, and reporting the response to the cloud

Order issuance

"Instruction issuance" is a function used to issue device control instructions. In order to enable the device to be controlled by users, developers must implement the "Instruction Issuance" function. The following takes "Issuing and Turning on the Power Switch" as an example to introduce the implementation instructions The process of delivering functions.

  1. The MIIO chip receives the downlink message of the app and translates it into a text command;
  2. The main control MCU continuously polled the MIIO chip with the "get_down" command, and got the text command;
  3. The master MCU completes the power-on operation
  4. The master control MCU calls the "result" response command to inform the MIIO chip to complete successfully
  5. The MIIO chip replied "ok", notifying that the result has been received, and reporting the response to the cloud

Serial command rules

When developers develop product firmware functions on the hardware product MCU, they need to design instructions according to the following rules:

  • Serial port configuration: 115200,8,1,N,N, does not support changes (in order to fully use the serial port command, please upgrade the module's firmware to 2.xx);
  • Command length: The total length must be less than 512 characters, and the serial port processing capability of the MCU must support the processing of commands with more than 512 bytes;
  • Command format: The first continuous string is the command name, followed by several parameters, cmd_name [ cmd_params ] ... [ cmd_params ] '\r';
  • Separator: Serial commands are separated by spaces, and spaces in non-character strings need to be escaped into \u0020;
  • End character: carriage return character'\r' (ie CR or 0x0D);
  • Instructions and parameters should be composed of legal characters, including letters, numbers, and underscores;
  • The local configuration command does not have a string type, and there is no need to add extra quotes [ "" ] to the parameters ;
  • The communication command of the server is based on JSON, and the string type in the communication command parameter of the server needs to add quotation marks [ "" ] ;

Note: If a developer encounters an error when developing product firmware using serial port commands, please refer to the document "Wi-Fi Product Development FAQ" to solve the problem.

Basic function instructions

model

After a developer creates a product on the Xiaomi IoT platform, he can get the product Model. The Model string consists of the company name, product category name, and product version, and the total length cannot exceed 23 characters.

Note: After the hardware product MCU is powered on, the product model should be reported to the Xiaomi IoT platform as soon as possible. The Xiaomi IoT platform will bind the module and the product model. Therefore, the developer should correctly configure the product model and the same module Do not reuse different models

  • Parameters: none or <model_name_string>
  • return value:
    • When there are no parameters, return the current model string;
    • With parameters, set the chip model to the parameter string and return ok;
    • If the parameter string is invalid, error is returned.
    ↑model   
    ↓xiaomi.dev.v1   
    ↑model xiaomi.prod.v2  
    ↓ok   
    ↑model   
    ↓xiaomi.prod.v2   
    ↑model company.product_name_that_is_too_long.v2   
    ↓error   
    ↑model plug   
    ↓error  

mcu_version

MCU should call this command to report the version immediately after the application firmware is booted, and ensure that the setting is successful and the module responds "ok"; if the downstream command receives MIIO_mcu_version_req, it should also report the MCU firmware version immediately, otherwise the product will fail Acceptance Test.

  • Parameters: <mcu_version_string>
  • Return value: If the parameter is legal, it returns ok, if it is illegal, it returns error.

Note: The MCU firmware version must be a 4-digit number.

    ↑mcu_version 0001  
    ↓ok  
    ↑mcu_version A001                                   
    ↓error  
    ↑mcu_version 1  
    ↓error 

ble_config (only dual-mode modules need to use this command)

Set and view the module PID and ble firmware version number.

  • Parameters: set <pid> <ble_version> or dump.
  • Return value: The command is ble_config set <pid> <ble_version> is used to set the Bluetooth PID of the dual-mode module (using decimal; for Bluetooth network configuration, PID is less than 65536), ble_version must be consistent with the MCU version; if the command is ble_config , Dump returns the current PID and ble firmware version of the module, otherwise it returns ok/error.
    ↑ ble_config set 156 0001                          
    ↓ ok  
    ↑ ble_config dump   
    ↓ ["product id":190,"version":1.3.0_0000]           

Server communication instructions

get_down

Get the downstream instructions.

  • Parameters: none

  • Return value:down <method_name> <arg1> <arg2> <arg3> ...

  • If there is no down command, it will immediately return to down none;

  • If there is a downstream command, it will immediately return the command name and command parameters (if there are parameters); the command name and the parameters are separated by spaces, and the parameters are separated by spaces; the parameters can be a string enclosed in double quotation marks or a number ; The returned command name may be get_properties, set_properties or action, corresponding to the corresponding device function definition, and the MCU needs to process the corresponding operation according to the device instance definition.

  • After the application firmware is booted, the MCU should call this command cyclically to obtain whether there is a command (the time range is 100~200ms, the recommended time interval is 200ms). If the MCU receives a downlink command, it should also respond immediately. For the command, the developer needs to use the error response module, otherwise the product will fail the acceptance test.

    ↑get_down                                          
    ↓down none  
    ↑get_down   
    ↓down set_properties 1 1 10   
    ↑result 1 1 0   
    ↓ok   
    ↑get_down   
    ↓down action 1 1   
    ↑get_down   
    ↓error  
    

result

Return the corresponding execution result according to different downstream commands

  • Parameters: <value1> <value2> ...
  • Return value: Return ok on success, error on failure.

Note: Up to 64 parameters are used after the instruction, and the entire instruction is up to 512 bytes.

    ↑get_down   
    ↓down set_properties 1 1 10                     
    ↑result 1 1 0   
    ↓ok  

error

  • Parameters: <error_code>
  • Return value: Return ok on success, error on failure.

Note: If the downstream command is executed incorrectly or receives an unrecognized command, the MCU can use this command to send error information. After sending successfully, return to MIIO chip to reply ok. The message must be a string enclosed in double quotes, and the error code must be an integer between -9999 and -5000 (including boundary values). The error message and error code can be customized.

    ↑get_down  
    ↓down error_cmd   
    ↑error "memory error" -5003                        
    ↓ok   
    ↑error "stuck" -5001   
    ↓ok 

properties_changed

Used to report attributes, the parameter must have at least a set of attribute iid and value.

  • format:properties_changed <siid> <piid> <value> ... <siid> <piid> <value>
  • Return value: ok or error.

Note: properties_changed is updated once per second, and the property with the same name within one second is only the last one reported to the Xiaomi IoT platform; when there is a corresponding property change locally, this command is called, and a maximum of 64 parameters are used after the command (the following example uses 6 Parameter), the entire instruction is up to 512 bytes.

    ↑properties_changed 1 1 17 1 2  "hi"               
    ↓ok   
    ↑properties_changed 1 1      
    ↓error   

Note: If the device needs to report SN, the developer can use the Spec definition in the product function definition (siid=1 piid=5), when the device is connected to the network, that is, net=cloud, properties_changed report the device SN code.

// Example
↑get_down
↓down MIIO_net_change cloud
// The format of SN needs to conform to the definition of String in spec, and the initial length should be 30 bytes
↑properties_changed 1 5 “12345/A026Z00001”
↓ok

event_occured

Used to report events

  • format:event_occured <siid> <eiid> <piid> <value> ... <piid> <value>
  • Return value: ok or error.

illustrate:
When the corresponding event changes locally, call this command to report the event event, event_occured is not more than 3 times per second;

  • Compared with properties_changed, the information when an event occurs will be updated to the Xiaomi IoT platform immediately. The properties_changed is updated every second, and the property with the same name within one second is only the last one reported to the Xiaomi IoT platform;
  • Up to 64 parameters are used after the instruction (6 parameters are used in the following example), and the entire instruction is up to 512 bytes.
    ↑event_occured 1 1 1 17 2  "hi"                    
    ↓ok   
    ↑event_occured 1       
    ↓error   

Serial tool debugging instructions

echo

  • Parameters: on or off
  • Return value: ok.

illustrate:
Turn on the serial port echo function. When this function is enabled, the serial port output of the MIIO chip will echo the input;

  • When serial port debugging is performed through the serial port tool, normal debugging may not be possible if the echo function is not turned on.

Control instruction

reboot

  • Parameters: none
  • Return value: ok.

Note: After the module receives this command, it will restart within 0.5 seconds.

    ↑reboot                             
    ↓ok  

restore

After the Xiaomi IoT module receives the command, the module will clear the Wi-Fi network configuration and remote control related information, and restart within 0.5s.

  • Parameters: none
  • Return value: ok
    ↑restore                                          
    ↓ok  

factory

After receiving the instruction, the MIIO chip enters the factory test mode within 2 seconds.

  • Parameters: none
  • Return value: ok

illustrate: In this mode, the chip will connect to the router according to the preset information;

  • Default router SSID: miio_default, password: 0x82562647;
  • The factory mode needs to ensure that it can only be triggered in the factory, and the device network status is local and connected to the router;
  • You can use reboot/restore to exit factory mode.
    ↑factory                                
    ↓ok  

Get module information command

net

Ask about the network status.

  • Parameters: none
  • Return value: offline or local or cloud or updating or uap or unprov

illustrate: offline-connecting (or offline);

  • local-connected to the router but not connected to the Mi Cloud Server;
  • updating-firmware upgrading, uap mode waiting for connection, unprov-close wifi (not connected quickly in half an hour).
    ↑net                                             
    ↓offline   
    ↑net   
    ↓local  
    ↑net  
    ↓cloud  

time

  • Parameters: none or posix
  • Return value: current date and time
    ↑time
    ↓2015-06-04 16:58:07
    ↑time posix
    ↓1434446397

mac

Get the mac address of the current module.

  • Parameters: none
  • Return value: the mac address of the current module
    ↑mac               
    ↓34ce00892ab7      

version

  • Parameters: none
  • Return value: Module firmware version number

Note: Some modules return the version of the serial port protocol (this protocol), and the firmware version of the module after the 2.xx version.

    ↑version                                            
    ↓2.0.0  

help

  • Parameters: none
  • Return value: all supported commands and parameter formats

Reserved downstream serial port commands

The MIIO chip reserves part of the command name to notify the hardware product MCU of specific events. This type of command can be obtained with get_down, but the MCU in the hardware product needs to be processed accordingly.

set_properties

Serial RPC Downlink Related Commands (Controlled by Xiaomi IoT Platform)

  • format: set_properties <siid> <piid> <value> ... <siid> <piid> <value>
  • Return value: result <siid> <piid> <code> ... <siid> <piid> <code>

The code value can refer to the "code status code definition" at the end of this document

Note: The set property of Xiaomi IoT platform needs to be processed by the MCU and the result is returned immediately. The general RPC communication of the module is 4S timeout failure. The reply result command uses up to 64 parameters (the following example uses 6 parameters), and the entire command is up to 512 words Section, otherwise the product will fail the acceptance test.

    ↑ get_down  
    ↓ down set_properties 1 1 10 1 88  "str_value"       
    ↑ result 1 1 0 1 88 -4003
    ↑properties_changed 1 1 10
    ↓ok

get_properties

  • format:get_properties <siid> <piid> ... <siid> <piid>
  • Return value:result <siid> <piid> <code> [value] ... <siid> <piid> <code> [value]

illustrate:
For the specific content of the code value, please refer to the "code status code definition" at the end of this document;

  • The get property of the Xiaomi IoT platform needs to be processed by the MCU and the result is returned immediately. The general RPC communication of the module is a 4S timeout failure. The reply result command uses up to 64 parameters (the following example uses 8 parameters), and the entire command is up to 512 bytes.
    ↑ get_down  
    ↓ down get_properties 1 2 1 3                        
    ↑ result 1 2 0 10 1 3 0 "str_value"

action

  • format:action <siid> <aiid> <piid> <value> ... <piid> <value>
  • Return value:result <siid> <aiid> <code> <piid> <value> ... <piid> <value>

illustrate: For the specific content of the code value, please refer to the "code status code definition" at the end of this document;

  • The Xiaomi IoT platform executes Action, which needs to be processed by the MCU and returns the result immediately. The general RPC communication of the module is a 4s timeout failure. The command uses up to 64 parameters (the following example uses 5 parameters), and the entire command is up to 512 bytes.
    ↑ get_down  
    ↓ down action 1 1 1 10                              
    ↑ result 1 1 0 3 10

MIIO_net_change

The network connection status of the Xiaomi IoT module has changed.
Return value: The parameter represents the latest network status of the chip. For detailed description of the network status, please refer to the net command. The developer can change the state of the Wi-Fi status light according to this command.

    ↑get_down  
    ↓down MIIO_net_change cloud                          

update_fw

Upgrade the MCU in the hardware product through the serial port. Different platforms have different limitations on the size of the MCU firmware (ESP(32)-WROOM-32D(32U) module MCU firmware is not greater than 1MB, MHCWB4P module MCU firmware is not greater than 236KB), details Please refer to the serial OTA document for introduction.

return value:

  • mcu can return "ready" and "busy";
  • Return "ready" to enter the normal upgrade process;
  • "Busy" is returned, indicating that the current status of the MCU cannot be upgraded, and the upgrade failure is returned to the server.
    ↑get_down  
    ↓down update_fw  
    ↑result "ready"  
    ↓ok  
    Enter xmodem to start downloading                                    

status code

code explanation
0 success
1 The request was received, but the operation has not been completed
-4001 Attribute is not readable
-4002 Property is not writable
-4003 Properties, methods, and events do not exist
-4004 Other internal errors
-4005 Attribute value error
-4006 Method in parameter error
-4007 did error