For fainter targets, the formula in the equation (2) of the manual (v 3.1) is not exactly correct for SDSS magnitudes, because SDSS uses asinh magnitudes with the "softening parameter" term for very faint objects.
Also, SDSS zero points for u and z bands have a slight shift from AB system, for all targets.
Just a note, in case somebody's science question needs a very precise determination.
For fainter targets, the formula in the equation (2) of the manual (v 3.1) is not exactly correct for SDSS magnitudes, because SDSS uses asinh magnitudes with the "softening parameter" term for very faint objects.
Also, SDSS zero points for u and z bands have a slight shift from AB system, for all targets.
Just a note, in case somebody's science question needs a very precise determination.
References:
https://www.sdss.org/dr12/algorithms/magnitudes/