-
-
Notifications
You must be signed in to change notification settings - Fork 125
/
number.ino
73 lines (58 loc) · 2.37 KB
/
number.ino
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
#include <Ethernet.h>
#include <ArduinoHA.h>
#define BROKER_ADDR IPAddress(192,168,0,17)
byte mac[] = {0x00, 0x10, 0xFA, 0x6E, 0x38, 0x4A};
EthernetClient client;
HADevice device(mac, sizeof(mac));
HAMqtt mqtt(client, device);
HANumber number("myNumber");
// You can also specify the precision of the number by providing the second argument to the constructor as follows:
// HANumber number("myNumber", HANumber::PrecisionP1);
// HANumber number("myNumber", HANumber::PrecisionP2);
// HANumber number("myNumber", HANumber::PrecisionP3);
void onNumberCommand(HANumeric number, HANumber* sender)
{
if (!number.isSet()) {
// the reset command was send by Home Assistant
} else {
// you can do whatever you want with the number as follows:
int8_t numberInt8 = number.toInt8();
int16_t numberInt16 = number.toInt16();
int32_t numberInt32 = number.toInt32();
uint8_t numberUInt8 = number.toUInt8();
uint16_t numberUInt16 = number.toUInt16();
uint32_t numberUInt32 = number.toUInt32();
float numberFloat = number.toFloat();
}
sender->setState(number); // report the selected option back to the HA panel
}
void setup() {
// you don't need to verify return status
Ethernet.begin(mac);
// set device's details (optional)
device.setName("Arduino");
device.setSoftwareVersion("1.0.0");
// handle command from the HA panel
number.onCommand(onNumberCommand);
// Optional configuration
number.setIcon("mdi:home");
number.setName("My number");
// number.setMin(1); // can be float if precision is set via the constructor
// number.setMax(100); // can be float if precision is set via the constructor
// number.setStep(0.5f); // minimum step: 0.001f
// number.setMode(HANumber::ModeBox);
// number.setMode(HANumber::ModeSlider);
// You can set retain flag for the HA commands
// number.setRetain(true);
// You can also enable optimistic mode for the HASelect.
// In this mode you won't need to report state back to the HA when commands are executed.
// number.setOptimistic(true);
mqtt.begin(BROKER_ADDR);
}
void loop() {
Ethernet.maintain();
mqtt.loop();
// You can also report the state to the HA panel at runtime as shown below.
// number.setState(1);
// number.setState(25.25f); // remember to change precision before using floats
}