forked from WCSim/WCSim
-
Notifications
You must be signed in to change notification settings - Fork 0
/
WCSim.mac
160 lines (131 loc) · 6.42 KB
/
WCSim.mac
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
# Sample setup macro with no visualization
/run/verbose 0
/tracking/verbose 0
/hits/verbose 0
## select the geometry
# Default config if you do nothing is currently SuperK
#
# The tube size is fixed for SK to 20"
# These are fixed geometries for validation
#/WCSim/WCgeom SuperK
# Some other SuperK options:
#/WCSim/WCgeom SuperK_20inchPMT_20perCent # Note: the actual coverage is 20.27%
#/WCSim/WCgeom SuperK_20inchBandL_20perCent # Note: the actual coverage is 20.27%
#/WCSim/WCgeom SuperK_12inchBandL_15perCent # Note: the actual coverage is 14.59%
#/WCSim/WCgeom SuperK_20inchBandL_14perCent # Note: the actual coverage is 13.51%
# HyperK (one cylindrical tank with a height of 54.8 m, a diameter of 70.8 m and 40% coverage with 20" B&L PMTs)
#/WCSim/WCgeom HyperK
#/WCSim/WCgeom HyperKWithOD
# Cylindrical detector with a height of 60 m and a diameter of 74 m
#/WCSim/WCgeom Cylinder_60x74_20inchBandL_14perCent # Note: the actual coverage is 13.51%
#/WCSim/WCgeom Cylinder_60x74_20inchBandL_40perCent
# Generic cylindrical detector with a height of 100m and a
# diameter of 69m with 12" HPD and 14.59% photocoverage
#/WCSim/WCgeom Cylinder_12inchHPD_15perCent # Note: the actual coverage is 14.59%
# Previous, egg-shaped HyperK design:
#/WCSim/WCgeom EggShapedHyperK #default length is 49500 mm unless changed in /WCSim/HK/waterTankLength below.
#/WCSim/WCgeom EggShapedHyperK_withHPD #default length is 49500 mm unless changed in /WCSim/HK/waterTankLength below.
#Changes the length of the simulated volume. Is currently only set up for the egg-shaped HyperK design.
#/WCSim/EggShapedHyperK/waterTank_Length 24750. mm # Equivalent length for 10 partitions
#/WCSim/EggShapedHyperK/waterTank_Length 49500. mm # Equivalent length for 5 partitions (default)
#/WCSim/EggShapedHyperK/waterTank_Length 61875. mm # Equivalent length for 4 partitions
#/WCSim/EggShapedHyperK/waterTank_Length 82500. mm # Equivalent length for 3 partitions
#/WCSim/EggShapedHyperK/waterTank_Length 123750. mm # Equivalent length for 2 partitions
#/WCSim/EggShapedHyperK/waterTank_Length 247500. mm # Equivalent length for 1 partition
#/WCSim/Construct # This must be uncommented in order to construct a new detector configuration.
#Added for the PMT QE option 08/17/10 (XQ)
# 1. Stacking only mean when the photon is generated
# the QE is applied to reduce the total number of photons
# 2. Stacking and sensitivity detector
# In the stacking part, the maximum QE is applied to reduce
# the total number of photons
# On the detector side, the rest of QE are applied according to QE/QE_max
# distribution. This option is in particular important for the WLS
# 3. The third option means all the QE are applied at the detector
# Good for the low energy running.
# 4. Switch off the QE complety, ie. set it at 100%
/WCSim/PMTQEMethod Stacking_Only
#/WCSim/PMTQEMethod Stacking_And_SensitiveDetector
#/WCSim/PMTQEMethod SensitiveDetector_Only
#/WCSim/PMTQEMethod DoNotApplyQE
#turn on or off the collection efficiency
/WCSim/PMTCollEff on
# command to choose save or not save the pi0 info 07/03/10 (XQ)
/WCSim/SavePi0 false
#choose the Trigger & Digitizer type (and options)
/DAQ/Digitizer SKI
/DAQ/Trigger NDigits
#/DAQ/Trigger NoTrigger
#grab the other DAQ options (thresholds, timing windows, etc.)
/control/execute macros/daq.mac
# default dark noise frequency (and conversion factor) is PMT property (NEW), set in the code.
# Below gives possibility to overwrite nominal values, eg. to switch OFF the Dark Noise.
#/DarkRate/SetDarkRate 0 kHz #Turn dark noise off
#/DarkRate/SetDarkRate 4.2 kHz #This is the value for SKI set in SKDETSIM.
#/DarkRate/SetDarkRate 8.4 kHz #For 20 inch HPDs and Box and Line PMTs, based on High QE 20" R3600 dark rate from EGADS nov 2014
#/DarkRate/SetDarkRate 3.0 kHz #For 12 inch HPDs and Box and Line PMTs, based on High QE 20" R3600 dark rate from EGADS nov 2014
# command to multiply the dark rate.
# Convert dark noise frequency before digitization to after digitization by setting suitable factor
# Again, this is now a PMT property and can be overridden here
#/DarkRate/SetConvert 1.367 #For Normal PMT
#/DarkRate/SetConvert 1.119 #For HPDs
#/DarkRate/SetConvert 1.126 #For Box and Line PMTs
# Select which time window(s) to add dark noise to
#/DarkRate/SetDarkMode 0 to add dark noise to a time window starting at
#/DarkRate/SetDarkLow to /DarkRate/SetDarkHigh [time in ns]
#/DarkRate/SetDarkMode 1 adds dark noise hits to a window of
#width /DarkRate/SetDarkWindow [time in ns] around each hit
#i.e. hit time ± (/DarkRate/SetDarkWindow) / 2
/DarkRate/SetDarkMode 1
/DarkRate/SetDarkHigh 100000
/DarkRate/SetDarkLow 0
/DarkRate/SetDarkWindow 4000
#Uncomment one of the lines below if you want to use the OGLSX or RayTracer visualizer
#/control/execute macros/visOGLSX.mac
#/control/execute macros/visRayTracer.mac
## select the input nuance-formatted vector file
## you can of course use your own
#/mygen/generator muline
#/mygen/vecfile inputvectorfile
#/mygen/vecfile h2o.2km.001-009x3_G4.kin
#/mygen/vecfile mu+.out
# Or you can use the G4 Particle Gun
# for a full list of /gun/ commands see:
# http://geant4.web.cern.ch/geant4/G4UsersDocuments/UsersGuides/ForApplicationDeveloper/html/Control/UIcommands/_gun_.html
/mygen/generator gun
/gun/particle e-
#/gun/particle pi0
/gun/energy 500 MeV
/gun/direction 1 0 0
/gun/position 0 0 0
# Or you can use the G4 General Particle Source
# you can do a lot more with this than a monoenergetic, monodirectional, single-particle gun
# for a full list of /gps/ commands see:
# https://geant4.web.cern.ch/geant4/UserDocumentation/UsersGuides/ForApplicationDeveloper/html/ch02s07.html
#/mygen/generator gps
#/gps/particle e-
#/gps/energy 500 MeV
#/gps/direction 1 0 0
#/gps/position 0 0 0
# Or you can use the laser option
# This is equivalent to the gps command, except that the gps particle energies are saved ignoring their mass
# for a full list of /gps/ commands see:
# https://geant4.web.cern.ch/geant4/UserDocumentation/UsersGuides/ForApplicationDeveloper/html/ch02s07.html
# It is used for laser calibration simulation
#/mygen/generator laser
#/gps/particle opticalphoton
#/gps/energy 2.505 eV
#/gps/direction 1 0 0
#/gps/position 0 0 0
#/gps/number 1000
#/gps/ang/type iso
#/gps/ang/mintheta 0 deg
#/gps/ang/maxtheta 30 deg
#/gps/ang/minphi 0 deg
#/gps/ang/maxphi 360 deg
## change the name of the output root file, default = wcsim.root
/WCSimIO/RootFile wcsim.root
## set a timer running on WCSimRunAction
#/WCSimIO/Timer false
/run/beamOn 10
#exit