scheric commented Apr 18, 2019

problem

the data i receive from the EMS bus is not right.

  • Boiler temperature (sometimes it is right picture below)
  • Pump modulation
  • Central heating
  • all thermostat information

my setup

nefit trendline <====> EMS-OT converter <===> Toon
                                \/
                         wemos d1 mini

EMS Bus stats:
  Bus Connected=yes, Tx is active, # Rx telegrams=10, # Tx telegrams=0, # Crc Errors=202

Boiler stats:
  Boiler type: Buderus GB172/Nefit Trendline (ProductID:123 Version:06.07)
  Hot tap water: off
  Central heating: off
  Warm Water activated: on
  Warm Water circulation pump available: off
  Warm Water comfort setting: Hot
  Warm Water selected temperature: 60 C
  Warm Water desired temperature: 70 C
  Warm Water current temperature: 45.1 C
  Warm Water current tap water flow: 0.0 l/min
  Warm Water # starts: 2956 times
  Warm Water active time: 3 days 8 hours 27 minutes
  Warm Water 3-way valve: off
  Selected flow temperature: 49 C
  Current flow temperature: 49.1 C
  Return temperature: 40.9 C
  Gas: on
  Boiler pump: on
  Fan: on
  Ignition: off
  Circulation pump: off
  Burner selected max power: 85 %
  Burner current power: 23 %
  Flame current: 25.9 uA
  System pressure: 1.1 bar
  System service code: -H (200)
  Heating temperature setting on the boiler: 70 C
  Boiler circuit pump modulation max power: 90 %
  Boiler circuit pump modulation min power: 40 %
  Outside temperature: ? C
  Boiler temperature: 2073 C
  Pump modulation: 0 %
  Burner # starts: 0 times
  Total burner operating time: 0 days 0 hours 0 minutes
  Total heat operating time: 0 days 0 hours 0 minutes
  Total UBA working time: 154 days 17 hours 38 minutes

Thermostat stats:
  Thermostat type: TypeID: 0x02 (ProductID:0 Version:?)
  Setpoint room temperature: ? C
  Current room temperature: ? C
  Thermostat time is 00:00:00 0/0/2000
  Mode is set to ?

boiler themp

@scheric scheric added the bug Something isn't working label Apr 18, 2019
@proddy
Copy link
Collaborator

proddy commented Apr 18, 2019

The "EMS-OT converter" is not properly implemented. See if you can locate what is happening from the telegrams you're getting and the code that is deciphering. In the meantime, I'll probably remove support for the OT converter

@proddy proddy closed this as completed Apr 18, 2019
@scheric
Copy link
Author

scheric commented Apr 18, 2019

Okay thanks for the info.
But that does not explain why

  • Boiler temperature (sometimes it is right picture below)
  • Pump modulation
  • Central heating

are not working properly. Or is the converter interfering with the boiler EMS codes.