Stepper Motor

Note: This legacy version is deprecated as of Firmata protocol v2.6.0 and therefore is not recommended for new implementations. Please use the new, more full-featured AccelStepper version instead.

Provides support for 4 wire and 2 wire stepper motor drivers (H-bridge, darlington array, etc) as well as step + direction drivers such as the EasyDriver. Current implementation supports 6 stepper motors at the same time (#[0-5]).

Also includes optional support for acceleration and deceleration of the motor.

Added in Firmata protocol version 2.4.0. Deprecated in Firmata protocol version 2.6.0.

Example files:

Protocol

Stepper configuration

Note: stepDelay is the the number of microseconds between steps. The default value is 1us. You can change the delay to 2us (useful for high current stepper motor drivers). Additional delay values can be added in the future.

0  START_SYSEX                       (0xF0)
1  Stepper Command                   (0x72)
2  config command                    (0x00 = config, 0x01 = step)
3  device number                     (0-5) (supports up to 6 motors)
4  stepDelay | interface             (upper 4 bits = step delay:
                                        0000XXX = default 1us delay [default]
                                        0001XXX = 2us delay
                                        additional bits not yet used)

                                     (lower 3 bits = interface:
                                        XXXX001 = step + direction driver
                                        XXXX010 = two wire
                                        XXXX100 = four wire)
5  steps-per-revolution LSB
6  steps-per-revolution MSB
7  motorPin1 or directionPin number  (0-127)
8  motorPin2 or stepPin number       (0-127)
9  [only when interface = 0x04] motorPin3 (0-127)
10 [only when interface = 0x04] motorPin4 (0-127)
11 END_SYSEX                         (0xF7)

Stepper step

0  START_SYSEX          (0xF0)
1  Stepper Command      (0x72)
2  config command       (0x01)
3  device number        (0-5)
4  direction            (0-1) (0x00 = CW, 0x01 = CCW)
5  num steps byte1 LSB
6  num steps byte2
7  num steps byte3 MSB  (21 bits (2,097,151 steps max))
8  speed LSB            (steps in 0.01*rad/sec  (2050 = 20.50 rad/sec))
9  speed MSB
10 [optional] accel LSB (acceleration in 0.01*rad/sec^2 (1000 = 10.0 rad/sec^2))
11 [optional] accel MSB
12 [optional] decel LSB (deceleration in 0.01*rad/sec^2)
13 [optional] decel MSB