WR3223 ventilation controller Binding

The WR3223 ventilation controller is used for room ventilation systems, for example in houses produced by company “Schwörer Haus”. The manufacturer of the controller is Hermes Electronic.

The WR3223 binding can read several measurements and the current state of the ventilation system. It can also adjust the fan speed, operation mode and the target temperature.

Note

The binding is currently in development. This is a first version of the OH2 WR3223 binding.

Prerequisites

The WR3223 can be connected by an RS232 or USB adapter. The adapter can be orderd from Hermes Electronic. If you want to connect the WR3223 by yourself, have a look at: https://community.openhab.org/t/wr3223-ventilation-controller-schworer-haus/

Binding Configuration

Thing Configuration

This binding can be configured in the file things/wr3223.things.

The connection must be configured via either the serialPort setting or via the host and port settings.

Property Default Required Description
serialPort Yes (if serial port is used) Serial port where the WR3223 is connected. E.g. /dev/ttyUSB0
host Yes (if TCP is used) IP address of the TCP to serial gateway
port Yes (if TCP is used) port number of the TCP to serial gateway
refresh 15000 No Refresh interval in milliseconds. The WR3223 needs a refresh at least every 20 seconds!
controllerAddr 1 No The controller address is normally 1.
# Example wr3223.things file
wr3223:controller:local [serialPort="/dev/ttyUSB0"]

Channels

The following table shows all known channels.

<channel-id> Item Type Read / Write Notes
temperature_evaporator Number Read de: Verdampfertemperatur (T1)
temperature_condenser Number Read de: Kondensatortemperatur (T2)
temperature_outside Number Read de: Aussentemperatur (T3)
temperature_outgoing_air Number Read de: Ablufttemperatur (Raumtemperatur) (T4)
temperature_after_heat_exchanger Number Read de: Temperatur nach Wärmetauscher (Fortluft) (T5)
temperature_supply_air Number Read de: Zulufttemperatur (T6)
temperature_after_brine_preheating Number Read de: Temperatur nach Solevorerwärmung (T7)
temperature_after_preheating Number Read de: Temperatur nach Wärmetauscher (T8)
rotation_speed_supply_air_motor Number Read de: Drehzahl Zuluftmotor
rotation_speed_exhaust_air_motor Number Read de: Drehzahl Abluftmotor
bypass Contact Read de: Zustand Bypass
compressor Contact Read de: Zustand Kompressor Relais
additional_heater_relais Contact Read de: Zustand Zusatzheizung Relais
additional_heater_status Contact Read de: Zusatzheizung An/Aus
additional_heater_open Switch Read / Write de: Zusatzheizung ausgeschaltet (0) oder freigegeben (1)
additional_heater_activate Switch Read / Write de: Zusatzheizung ein/ausschalten
bypass_relay Contact Read de: Zustand Netzrelais Bypass
preheating_radiator_active Contact Read de: Vorheizen aktiv
control_device_active Contact Read de: Bedienteil aktiv
earth_heat_exchanger Contact Read de: Erdwärmetauscher
magnet_valve Contact Read de: Magnetventil
openhab_interface_active Contact Read de: Bedienung über RS Schnittstelle (WR3223 Binding)
preheating_radiator Contact Read de: Vorheizregister
warm_water_post_heater Contact Read de: WW Nachheizregister
ventilation_level_available Contact Read de: Luftstufe vorhanden
ventilation_level Number Read / Write de: Aktuelle Luftstufe
operation_mode Number Read / Write de: Betriebsart
cooling_mode Switch Read / Write de: Kühlen
temperature_supply_air_target Number Read / Write de: Zuluftsoll Temperatur
heat_feedback_rate Number Read de: Aktuelle Rückwärmzahl in %
speed_deviation_max_level_1 Number Read / Write de: Max. Drehzahlabweichung Zu-/Abluft in Stufe 1
speed_deviation_max_level_2 Number Read / Write de: Max. Drehzahlabweichung Zu-/Abluft in Stufe 2
speed_deviation_max_level_3 Number Read / Write de: Max. Drehzahlabweichung Zu-/Abluft in Stufe 3
speed_increase_earth_heat_exchanger_level_1 Number Read / Write de: Drehzahlerhöhung Zuluftventilator Stufe 1, wenn Erdwärmetauscher ein (0% bis 40%)
speed_increase_earth_heat_exchanger_level_2 Number Read / Write de: Drehzahlerhöhung Zuluftventilator Stufe 2, wenn Erdwärmetauscher ein (0% bis 40%)
speed_increase_earth_heat_exchanger_level_3 Number Read / Write de: Drehzahlerhöhung Zuluftventilator Stufe 3, wenn Erdwärmetauscher ein (0% bis 40%)
air_exchange_decrease_outside_temperature Number Read / Write de: Luftwechsel um 3% reduziert ab Außentemp. ...°C (-20°C bis +10°C)
ventilation_speed_level_1 Number Read / Write de: Luftstufe 1, % des max. Ventilatorstellwerts (40 bis 100%)
ventilation_speed_level_2 Number Read / Write de: Luftstufe 2, % des max. Ventilatorstellwerts (40 bis 100%)
ventilation_speed_level_3 Number Read / Write de: Luftstufe 3, % des max. Ventilatorstellwerts (40 bis 100%)
summer_earth_heat_exchanger_activation_temperature Number Read / Write de: Einschalt-Außentemperatur Erdwämietauscher im Sommer (20°C bis 40°C)
winter_earth_heat_exchanger_activation_temperature Number Read / Write de: Einschalt-Außentemperatur Erdwärmetauscher im Winter (-20°C bis 10°C)
defrosting_start_temperature Number Read / Write de: Beginn Abtauung ab Verdampfertemperatur ...°C
defrosting_end_temperature Number Read / Write de: Ende Abtauung ab Verdampfertemperatur ...°C
defrosting_ventilation_level Number Read / Write de: Lüfterstufe im Abtaubetrieb
defrosting_hold_off_time Number Read / Write de: Sperrzeit für den nächsten Abtauvorgang
defrosting_overtravel_time Number Read / Write de: Abtaunachlauzeit
defrosting_heat_feedback_rate Number Read / Write de: Abtaurückwärmezahl Schaltpunkt (20% bis 80 %)
solar_max Number Read / Write de: Solar max
solar_usage Number Read de: Solar Nutzen (Stunden)
delta_t_off Number Read / Write de: Delta T Aus Temperaturdifferenz zwischen Speicher u. Kollektor
delta_t_on Number Read / Write de: Delta T Ein Temperaturdifferenz zwischen Speicher u. Kollektor
temperature_condenser_max Number Read / Write de: Maximale Kondensatortemperatur
idle_time_pressure_reduction Number Read / Write de: Pausezeit für Druckabbau bei automatischer Umschaltung
support_fan_level_1_earth_heat_exchanger Number Read / Write de: Unterstuetzungsgeblaese bei Luftstufe 1 bei EWT
support_fan_level_2_earth_heat_exchanger Number Read / Write de: Unterstuetzungsgeblaese bei Luftstufe 2 bei EWT
support_fan_level_3_earth_heat_exchanger Number Read / Write de: Unterstuetzungsgeblaese bei Luftstufe 3 bei EWT
control_voltage_outgoing_air Number Read de: Steuerspannung Abluft
control_voltage_supply_air Number Read de: Steuerspannung Zuluft
warm_water_target_temperature Number Read / Write de: Warmwasser Sollwert
heat_pump_status Contact Read de: Wärmepumpe An/Aus
heat_pump_open Switch Read / Write de: Wärmepumpe freigegeben (1) oder aus (0)
heat_pump_activate Switch Read / Write de: Wärmepumpe Ein/-Ausschalten
evu_blockade Contact Read de: EVU Abschaltung
malfunction Contact Read de: Störung vorhanden
error_temp_sensor_short Contact Read de: Kurzsch. TS
error_offset Contact Read de: Offset error
error_temp_sensor_interupt Contact Read de: Unterbr. TS
error_high_pressure Contact Read de: Hochdruckfehler
error_sys_ram Contact Read de: Error sys ram
error_sys_rom Contact Read de: Error sys rom
error_sys_ee Contact Read de: Error sys ee
error_sys_io Contact Read de: Error sys io
error_sys_67_ad Contact Read de: Error sys 67 ad
error_supply_air Contact Read de: Zuluft fehlt
error_outgoing_air Contact Read de: Abluft fehlt
error_condenser Contact Read de: Kondensationsfehler
error_preheating Contact Read de: Vorheizfehler
# Example wr3223.items file
Number:Dimensionless LF_EquipmentRoom_Ventilation_OperationMode  "Betriebsart [%.0f]"            <fan>         {channel="wr3223:controller:local:operationMode"}
Number LF_EquipmentRoom_Ventilation_VentilationLevel             "Lüftungsstufe"                               {channel="wr3223:controller:local:ventilationLevel"}
Number:Temperature LF_EquipmentRoom_Ventilation_AirTargetTemp    "Soll Temperatur [%.1f]"        <temperature> {channel="wr3223:controller:local:temperatureSupplyAirTarget"}