Skip to content

Latest commit

 

History

History

docs

Folders and files

NameName
Last commit message
Last commit date

parent directory

..
 
 
 
 
 
 
 
 

Metalnet Documentation

Developement and automated testing

API references

CRD usage

Multiport-eswitch mode

When running dpservice with Mellanox in multiport-eswitch mode, it is important to tell metalnet about it:

metalnet --multiport-eswitch

or (overrides the above)

echo -n "eswitch" > /var/lib/metalnet/mode

This changes the way metalnet generates identifiers for virtual function representors that are sent over to dpservice.

If pf1-proxy is also in use, it is important to mark it as used in the metalnet VF database:

mkdir -p /var/lib/metalnet/netfns/claims
echo -n "$pf1_proxy_vf_pci" > /var/lib/metalnet/netfns/claims/00000001-0000-4000-0000-000000000000

Where the $pf1_proxy_vf_pci is the PCI address of the VF representor for pf1-proxy. This should be the only VF using mlx5_core driver instead of the vfio-pci driver. One of many ways to retrieve such address is as follows:

pf1_proxy_vf_name=$(/opt/local/bin/dpdk-devbind.py -s | grep "mlx5Gen Virtual Function" | grep "drv=mlx5_core" | awk -F'if=' '{print $2}' | awk '{print $1}')
pf1_proxy_vf_pci=$(/opt/local/bin/dpdk-devbind.py -s | grep "mlx5Gen Virtual Function" | grep $pf1_proxy_vf_name | awk '{print $1}')