You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The clock frequency values are reversed in the schematics and iBOM. The correct values are X1: 50MHz, X2: 25MHz.
X1 always drives the CPU clock and will drive the FPU clock when J202 is set by shorting pins 1 and 2.
X2 will drive the FPU only when J202 is set by shorting pins 2 and 3.
The text was updated successfully, but these errors were encountered:
The clock frequency values are reversed in the schematics and iBOM. The correct values are X1: 50MHz, X2: 25MHz.
X1 always drives the CPU clock and will drive the FPU clock when J202 is set by shorting pins 1 and 2.
X2 will drive the FPU only when J202 is set by shorting pins 2 and 3.
The text was updated successfully, but these errors were encountered: