This repository has been archived by the owner. It is now read-only.
-
Notifications
You must be signed in to change notification settings - Fork 40
/
AT-LOOPPROTECT-MIB
120 lines (106 loc) · 3.67 KB
/
AT-LOOPPROTECT-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
-- ===========================================================================
-- AT-LOOPPROTECT.MIB, Allied Telesis enterprise
--
-- Copyright (c) 2008 by Allied Telesis, Inc.
-- All rights reserved.
--
-- ===========================================================================
AT-LOOPPROTECT-MIB DEFINITIONS ::= BEGIN
IMPORTS
modules
FROM AT-SMI-MIB
InterfaceIndex
FROM IF-MIB
OBJECT-TYPE,
MODULE-IDENTITY,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
;
-- atLoopProtect - this group contains information about Loop Protection modules.
atLoopProtect MODULE-IDENTITY
LAST-UPDATED "200809220000Z"
ORGANIZATION "Allied Telesis, Inc."
CONTACT-INFO
"http://www.alliedtelesis.com"
DESCRIPTION
"This MIB file contains definitions of managed objects for the
Loop Protection modules."
REVISION "200808120000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { modules 54 }
atLoopProtectAction OBJECT-TYPE
SYNTAX INTEGER {
atLoopProtectAction-LearnDisable(0),
atLoopProtectAction-LearnEnable(1),
atLoopProtectAction-PortDisable(2),
atLoopProtectAction-PortEnable(3),
atLoopProtectAction-LinkDown(4),
atLoopProtectAction-LinkUp(5),
atLoopProtectAction-VlanDisable(6),
atLoopProtectAction-VlanEnable(7)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Action for Loop Protection feature"
::= { atLoopProtect 1 }
atLoopProtectIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface where the loop is detected on."
::= { atLoopProtect 2 }
atLoopProtectVlanId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN ID where the loop is detected on."
::= { atLoopProtect 3 }
atLoopProtectRxLDFIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface where the loop detection frame is received on."
::= { atLoopProtect 4 }
atLoopProtectRxLDFVlanId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN ID where the loop detection frame is received on."
::= { atLoopProtect 5 }
-- atLoopProtect traps - traps exist for changes to detect a packet loop.
atLoopProtectTrap OBJECT IDENTIFIER ::= { atLoopProtect 0 }
atLoopProtectDetectedLoopBlockedTrap NOTIFICATION-TYPE
OBJECTS { atLoopProtectIfIndex,
atLoopProtectVlanId,
atLoopProtectAction
}
STATUS current
DESCRIPTION
"Generated when Loop Protection feature blocks a interface with a loop."
::= { atLoopProtectTrap 1 }
atLoopProtectRecoverLoopBlockedTrap NOTIFICATION-TYPE
OBJECTS { atLoopProtectIfIndex,
atLoopProtectVlanId,
atLoopProtectAction
}
STATUS current
DESCRIPTION
"Generated when Loop Protection feature restores a blocked interface back to normal operation."
::= { atLoopProtectTrap 2 }
atLoopProtectDetectedByLoopDetectionTrap NOTIFICATION-TYPE
OBJECTS { atLoopProtectIfIndex,
atLoopProtectVlanId,
atLoopProtectRxLDFIfIndex,
atLoopProtectRxLDFVlanId
}
STATUS current
DESCRIPTION
"Generated when Loop Protection feature detects a loop by Loop Detection method."
::= { atLoopProtectTrap 3 }