Increase the values of MH_URB2D_MIN,MH_URB2D,MH_URB2D_MAX for LCZ 7 of the look up table to
4,5,6 m
instead of
2,3,4m.
This is because the minimum building height that we can assign to BEP-BEM is 5m if we use dz_u=5m (standard value), so there is no point to have a mean building height lower than that. In addition, this will increase the mean street width to 3.33m instead of 2m, which seems more realistic to me,
The text was updated successfully, but these errors were encountered:
Suggestion from Alberto Martilli, via email:
Increase the values of MH_URB2D_MIN,MH_URB2D,MH_URB2D_MAX for LCZ 7 of the look up table to
4,5,6 m
instead of
2,3,4m.
This is because the minimum building height that we can assign to BEP-BEM is 5m if we use dz_u=5m (standard value), so there is no point to have a mean building height lower than that. In addition, this will increase the mean street width to 3.33m instead of 2m, which seems more realistic to me,