Running scanservjs under docker

If you're already running Debian, Ubuntu or similar, and haven't used docker before then it's probably easier just to install directly. For what it's worth, that is my preferred installation method.

Quickstart

Get the image

docker pull sbs20/scanservjs:latest

Run it

docker rm --force scanservjs-container 2> /dev/null
docker run -d \
  -p 8080:8080 \
  -v /var/run/dbus:/var/run/dbus \
  --restart unless-stopped \
  --name scanservjs-container \
  --privileged sbs20/scanservjs:latest

General notes

  • ⚠ By default, configuration and scanned images are stored within the container and will be lost if you recreate it. If you want to map your scanned images then see mapping section below
  • ✅ The docker image now supports arm as well as amd64.

Accessing hardware

Docker is great for certain tasks. But it's less ideal for situations where the container needs to access the host hardware. The "simple" solution is to run with --privileged but that gives your container full root access to the host - you're putting a lot of trust in the container. In short, best not.

Depending on your setup you have a number of options:

  • If your scanner is connected by USB to the host, and there are standard SANE drivers, then you can map the device. The best way to do this is to map the actual USB ports.

    • In case you scanner is always plugged to your device:
      • Run sudo sane-find-scanner -q and you will get a result like found USB scanner (vendor=0x04a9 [Canon], product=0x220d [CanoScan], chip=LM9832/3) at libusb:001:003.
      • Or run lsusb which gives you Bus 001 Device 003: ID 04a9:220d Canon, Inc. CanoScan N670U/N676U/LiDE 20.
      • Both translate to /dev/bus/usb/001/003.
      • The docker argument would be --device=/dev/bus/usb/001/003:/dev/bus/usb/001/003
      • You may also need to adjust permissions on the USB port of the host e.g. chmod a+rw dev/bus/usb/001/003 - see this helpful answer for more.
    • In case your scanner is not always plugged, the device path will change every so often, and the previous solution will not work. Also, some devices will go to sleep after long idle times, effectively getting "unplugged" and "plugged again" over and over.
      In this case, you may use udev so that it starts or re-configures your container whenever your scanner is hot-plugged. This is suggested in the official Docker documentation:
      • Run lsusb to retrieve your device "vendor ID" and "product ID". In the example above, Bus 001 Device 003: ID 04a9:220d Canon, Inc. CanoScan N670U/N676U/LiDE 20 means that the vendor ID is 04a9, and the product ID is 220d.
      • Add a udev rule /etc/udev/rules.d/50-add-scanner.rules
        ACTION=="add", ATTR{idVendor}=="04a9", ATTR{idProduct}=="1774", RUN+="/etc/scan/bind-scanner-to-container.sh $name $major $minor $attr{idVendor} $attr{idProduct}"
        
      • Make udev aware of this change: sudo udevadm control --reload-rules
      • This will run the following script every time the scanner is plugged. /etc/scan/bind-scanner-to-container.sh
        #!/bin/bash
        # This script must be executable by root
        DEVICE_PATH="$1"
        MAJOR_NUMBER="$2"
        MINOR_NUMBER="$3"
        
        # USB identifiers of the device
        VENDOR_ID="$4"
        PRODUCT_ID="$5"
        
        CONTAINER_NAME="scan"
        IMAGE_NAME="sbs20/scanservjs:release-v2.25.0"
        
        logger "Scanner ($VENDOR_ID:$PRODUCT_ID) is available at $DEVICE_PATH. Let's make it available to the scan server container"
        
        # Is the container running already?
        container_id=$(docker ps -q -f name=scddan)
        if [ -z "$container_id" ]; then
            # Container was not running. We should start it, with the right device ID
            device_nb=$(lsusb | grep "$VENDOR_ID:$PRODUCT_ID" | grep -o -E "Device [0-9]+" | grep -o -E "[0-9]+")
        
            if [ -z "$device_nb" ]; then
                logger "Unable to find where this device is connected. Ignoring."
                exit 1
            fi
        
            # Waiting for Docker to be available (if the scanner is plugged when the host boots, udev will trigger this script before Docker is even started)
            attempts=0
            while true ; do
                if [ "$(systemctl is-active docker)" == "active" ]; then
                    break
                fi
                sleep 10
                attempts=$(( attempts + 1 ))
                if [ "$attempts" -gt 10 ]; then
                    logger "Docker is not running. Will not start scan server."
                    exit 1
                fi
            done
        
            logger "Starting the scan server from $IMAGE_NAME, with device $device_nb ($VENDOR_ID:$PRODUCT_ID, major number is $MAJOR_NUMBER)..."
            # --device adds the existing device to the container.
            # --device-cgroup-rule makes it possible to add future hot-plugged devices
            # see https://docs.docker.com/engine/reference/commandline/run/#device-cgroup-rule
            docker run -d \
              --rm \
              -p 8080:8080 \
              -v /var/run/dbus:/var/run/dbus \
              -v /path/to/the/optional/scan/folder:/app/data/output \
              -v /path/to/the/optional/custom/config:/app/config \
              --name "$CONTAINER_NAME" \
              --device=/dev/bus/usb/001/"$device_nb":/dev/bus/usb/001/"$device_nb" \
              --device-cgroup-rule="c $MAJOR_NUMBER:* rmw" \
              "$IMAGE_NAME" 2>&1 | logger
        else
            # Container is running. We just have to add the device there
            logger "Adding the new scanner to the scan server container..."
            docker exec "$CONTAINER_NAME" mknod "/dev/$DEVICE_PATH" c "$MAJOR_NUMBER" "$MINOR_NUMBER" 2>&1 | logger
        fi
      • If you prefer, you may tweak both files above e.g. to stop the container when the scanner is disconnected, and re-start the container when the device is re-connected.
  • If your scanner is driverless over the network, then sane-airscan should be able to figure it out - but it uses Avahi / Zeroconf / Bonjour to discover devices on the local network. You will want to share dbus to make it work (-v /var/run/dbus:/var/run/dbus).

  • If your container is running inside a VM you may find that the USB device id is unstable and changes between boots. In these cases, you will probably find it easier to share the scanner over the network on the host.

  • If you need proprietary drivers for your scanner then the best solution is either to install the drivers on the host and share it over the network or to create your own docker image based on the scanservjs one and add it in that way.

    Here is an example on how one particular Brother scanner model and its driver can be installed in the Dockerfile. The driver (brscan4-0.4.10-1.amd64.deb) needs to be placed next to the Dockerfile, then:

    COPY brscan4-0.4.10-1.amd64.deb "$APP_DIR/brscan4-0.4.10-1.amd64.deb"
    RUN apt install -yq "$APP_DIR/brscan4-0.4.10-1.amd64.deb" \
    && brsaneconfig4 -a name=ADS-2600W model=ADS-2600W nodename=10.0.100.30

    Note: The addition of more backends to the docker container is not planned since it would mostly add cruft for most users who don't need it.

  • Driverless-mode scanning (using airscan over IPP-USB) seems to result in problems. If anyone has ideas why (perhaps something additional needs sharing from host to guest) then suggestions are welcome.

  • The best fallback position for most cases is simply to share the host scanner over the network on the host (where the scanner is connected) and then set the SANED_NET_HOSTS environment variable on the docker container. This user uses docker compose instead. See examples below.

Mapping volumes

To access data from outside the docker container, there are two volumes you may wish to map:

  • The scanned images: use -v /local/path/scans:/app/data/output
  • Configuration overrides: use -v /local/path/cfg:/app/config

User and group mapping

When mapping volumes, special attention must be paid to users and file systems permissions.

The docker container runs as root by default. Changing the user's UID (e.g. by using -u 1000 for docker run) to access scans/configuration from outside docker is not advised since it will cause scans to fail.. If running as a different user is important to you then see the scanservjs-user2001 target in ../Dockerfile.

Your alternatives are:

  1. changing the group of the container to a known group on the host e.g. -u 0:1000. This will keep the user correct (0) but change the group (1000).
  2. building a docker image with a custom UID/GID pairing: clone this repository and run docker build --build-arg UID=1234 --build-arg GID=5678 -t scanservjs_custom . (with UID and GID adjusted to your liking), then run the custom image (e.g. docker run scanservjs_custom).
  3. as a last resort, changing the host volume permissions e.g. chmod 777 local-volume

Environment variables

  • SANED_NET_HOSTS: If you want to use a SaneOverNetwork scanner then to perform the equivalent of adding hosts to /etc/sane.d/net.conf specify a list of ip addresses separated by semicolons in the SANED_NET_HOSTS environment variable.
  • AIRSCAN_DEVICES: If you want to specifically add sane-airscan devices to your /etc/sane.d/airscan.conf then use the AIRSCAN_DEVICES environment variable (semicolon delimited).
  • DELIMITER: if you need to include semi-colons (;) in your environment variables, this allows you to choose an alternative delimiter.
  • DEVICES: Force add devices use DEVICES (semicolon delimited)
  • SCANIMAGE_LIST_IGNORE: To force ignore scanimage -L

Examples

Connect to the scanner over the network (recommended)

docker run -d -p 8080:8080 \
  -e SANED_NET_HOSTS="10.0.100.30" \
  --name scanservjs-container sbs20/scanservjs:latest

Mapped USB device with mapped volumes

docker run -d -p 8080:8080 \
  -v $HOME/scan-data:/app/data/output \
  -v $HOME/scan-cfg:/app/config \
  --device /dev/bus/usb/001/003:/dev/bus/usb/001/003 \
  --name scanservjs-container sbs20/scanservjs:latest

Use airscan and a locally detected scanner

This should support most use cases

docker run -d -p 8080:8080 \
  -v /var/run/dbus:/var/run/dbus \
  --name scanservjs-container sbs20/scanservjs:latest

A bit of everything

Add two net hosts to sane, use airscan to connect to two remote scanners, don't use scanimage -L, force a list of devices, override the OCR language and run in privileged mode

docker run -d -p 8080:8080 \
  -e SANED_NET_HOSTS="10.0.100.30;10.0.100.31" \
  -e AIRSCAN_DEVICES='"Canon MFD" = "http://192.168.0.10/eSCL";"EPSON MFD" = "http://192.168.0.11/eSCL"' \
  -e SCANIMAGE_LIST_IGNORE=true \
  -e DEVICES="net:10.0.100.30:plustek:libusb:001:003;net:10.0.100.31:plustek:libusb:001:003;airscan:e0:Canon TR8500 series;airscan:e1:EPSON Cool Series" \
  -e OCR_LANG="fra" \
  -v /var/run/dbus:/var/run/dbus \
  --name scanservjs-container --privileged sbs20/scanservjs:latest

Hosting it on a Synology NAS using Docker

It can be convenient to host scanservjs on the same machine where you store your scans — your NAS. Here's a possible approach for network scanning with a Synology NAS:

  1. Install the Synology Docker package.
  2. In DSM, create a service user "scanservjs" which will run the Docker container. Make sure to give it write permission to the preferred target location for scans. We'll use /volume1/scans.
  3. SSH with an admin account onto the NAS and use id to determine the UID and GID of the service user just created:
    admin@synology:~$ id scanservjs
    uid=1034(scanservjs) gid=100(users) groups=100(users),65538(scanusers)
    Keep the session open, we'll need it again in a moment.
  4. On your workstation, download and extract the latest scanservjs release.
  5. In the repository root, create a text file named docker-compose.yml with the following content:
    version: "3"
    services:
      scanservjs:
        build:
          context: .
          args:
            # ----- enter UID and GID here -----
            UID: 1034
            GID: 100
          target: scanservjs-user2001
        container_name: scanservjs
        environment:
          # ----- specify network scanners here; see above for more possibilities -----
          - SANED_NET_HOSTS="10.0.100.30"
        volumes:
          # ---- enter your target location for scans before the ':' character -----
          - /volume1/scans:/app/data/output
          - ./config:/app/config
        ports:
          - 8080:8080
        restart: unless-stopped
  6. Copy the entire repository including docker-compose.yml onto your NAS (via smb, sftp, ...).
  7. In your SSH session from earlier, cd to the repository location and run
    sudo docker-compose up -d
  8. After a medium-sized cup of tea, scanservjs should be available at http://<NAS IP Address>:8080
  9. Bonus: Create a reverse proxy rule in the Application Portal so that scanservjs can be reached via http://scan.synology.lan (or similar). Scanning can be slow, so set the proxy timeouts to 300 seconds or more to prevent timeout issues.

Staging builds

These may be less stable, but also have upcoming features.

If you want to install the latest staging branch (this may contain newer code)

docker pull sbs20/scanservjs:staging
docker rm --force scanservjs-container 2> /dev/null
docker run -d -p 8080:8080 -v /var/run/dbus:/var/run/dbus --restart unless-stopped --name scanservjs-container --privileged sbs20/scanservjs:staging