Things preceded by a # are done with this release (0.8)
0. Add support for FORTRAN. Deserves it more than VB.
#1. Define and implement a consistent way to handle debug output, so that the user
# can direct it to a file of choice.
All debug output should now go to standard error
#2. Write safer test programs, i.e. do write operations only with special options
# or/and after explicit confirmation.
#3. Write code to support ISO over TCP.
4. Make a completely unified versions for all sorts of transports.
# This will result in a single library.
# There should be a table containig the positions of headers and PDU in the packet.
# Maybe this table should also contain pointers to the functions actually needed.
# Done also for IBH NetLink.
5. Evaluate error codes returned from PLC.
Current suspicions for read results:
The first data byte in the returned result means:
255 Success
3 Not a readable data area.
5 Read past end of area = not enough data for this read request.
10 data item not available
There are more error codes the CPU puts into response PDUs of type 2 and 3.
#6. Integrate Andrew's protocol from the rostic subdirectory. Find out what is the difference
# between it and the protocol currently used in the main branch.
# It does not include the MPI address of receiver (and sender?) in each packet, so maybe
# it cannot be used in an MPI net with multiple masters.
# Once I have initialized my MPI adapter to use it, I cannot connect with the other protocol
# unless I remove the power from the adapter.
Done. Specify daveProtoMPI2 in daveNewConnection. I found it worked with an adapter that seems
not to support my former version.
7. Find out whether there is an ISO transport in raw ethernet packets used in Siemens
devices and write support for it.
#8. Support multiple item read requests.
#8. Support multiple item write requests.
#9. I suppose that it is possible to set some fields in the PDU to some ID, which is then
# returned unchanged in the answer. This could be used to build up a mechanism to accept
# packets from more than one application and transmit them with different IDs to the PLC.
# The answers could then be delivered to the respective application.
# A possible application for this would be to access the PLC with a programming device
# while running a SCADA application.
This is possible using multiple connections.
#10. Find out where to put the local MPI address of the PC in the protocol used by MPI
# adapters.
Should now work. For IBH NetLink, you have to configure the local address via IBH setup software.
11. Add support for more data areas (instance data blocks, timers, counters, system data)
if possible.
12. Add functions for teleservice.
#13. Find out how other functions like program up-/download, start,stop etc. work.
# start,stop work
# reading program from PLC works
# loading program into PLC works
14. Add support for CP5511, CP5611, CP5512 etc.
# at least for win32 and if Step7 or maybe other Siemens products are installed,
# libnodave can now use s7onlinx.dll for transport.