forked from kedacore/keda
-
Notifications
You must be signed in to change notification settings - Fork 0
/
main.go
178 lines (154 loc) · 5.85 KB
/
main.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
/*
Copyright 2021 The KEDA Authors
Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS,
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
See the License for the specific language governing permissions and
limitations under the License.
*/
package main
import (
"flag"
"fmt"
"os"
"runtime"
"time"
apimachineryruntime "k8s.io/apimachinery/pkg/runtime"
utilruntime "k8s.io/apimachinery/pkg/util/runtime"
clientgoscheme "k8s.io/client-go/kubernetes/scheme"
_ "k8s.io/client-go/plugin/pkg/client/auth"
ctrl "sigs.k8s.io/controller-runtime"
"sigs.k8s.io/controller-runtime/pkg/controller"
"sigs.k8s.io/controller-runtime/pkg/healthz"
"sigs.k8s.io/controller-runtime/pkg/log/zap"
kedav1alpha1 "github.com/kedacore/keda/v2/apis/keda/v1alpha1"
kedacontrollers "github.com/kedacore/keda/v2/controllers/keda"
kedautil "github.com/kedacore/keda/v2/pkg/util"
"github.com/kedacore/keda/v2/version"
//nolint:gci
//+kubebuilder:scaffold:imports
)
var (
scheme = apimachineryruntime.NewScheme()
setupLog = ctrl.Log.WithName("setup")
)
func init() {
utilruntime.Must(clientgoscheme.AddToScheme(scheme))
utilruntime.Must(kedav1alpha1.AddToScheme(scheme))
//+kubebuilder:scaffold:scheme
}
// getWatchNamespace returns the namespace the operator should be watching for changes
func getWatchNamespace() (string, error) {
const WatchNamespaceEnvVar = "WATCH_NAMESPACE"
ns, found := os.LookupEnv(WatchNamespaceEnvVar)
if !found {
return "", fmt.Errorf("%s must be set", WatchNamespaceEnvVar)
}
return ns, nil
}
func main() {
var metricsAddr string
var enableLeaderElection bool
var probeAddr string
flag.StringVar(&metricsAddr, "metrics-bind-address", ":8080", "The address the metric endpoint binds to.")
flag.StringVar(&probeAddr, "health-probe-bind-address", ":8081", "The address the probe endpoint binds to.")
flag.BoolVar(&enableLeaderElection, "leader-elect", false,
"Enable leader election for controller manager. "+
"Enabling this will ensure there is only one active controller manager.")
opts := zap.Options{}
opts.BindFlags(flag.CommandLine)
flag.Parse()
ctrl.SetLogger(zap.New(zap.UseFlagOptions(&opts)))
namespace, err := getWatchNamespace()
if err != nil {
setupLog.Error(err, "failed to get watch namespace")
os.Exit(1)
}
mgr, err := ctrl.NewManager(ctrl.GetConfigOrDie(), ctrl.Options{
Scheme: scheme,
MetricsBindAddress: metricsAddr,
Port: 9443,
HealthProbeBindAddress: probeAddr,
LeaderElection: enableLeaderElection,
LeaderElectionID: "operator.keda.sh",
Namespace: namespace,
})
if err != nil {
setupLog.Error(err, "unable to start manager")
os.Exit(1)
}
// default to 3 seconds if they don't pass the env var
globalHTTPTimeoutMS, err := kedautil.ResolveOsEnvInt("KEDA_HTTP_DEFAULT_TIMEOUT", 3000)
if err != nil {
setupLog.Error(err, "Invalid KEDA_HTTP_DEFAULT_TIMEOUT")
os.Exit(1)
}
scaledObjectMaxReconciles, err := kedautil.ResolveOsEnvInt("KEDA_SCALEDOBJECT_CTRL_MAX_RECONCILES", 5)
if err != nil {
setupLog.Error(err, "Invalid KEDA_SCALEDOBJECT_CTRL_MAX_RECONCILES")
os.Exit(1)
}
scaledJobMaxReconciles, err := kedautil.ResolveOsEnvInt("KEDA_SCALEDJOB_CTRL_MAX_RECONCILES", 1)
if err != nil {
setupLog.Error(err, "Invalid KEDA_SCALEDJOB_CTRL_MAX_RECONCILES")
os.Exit(1)
}
globalHTTPTimeout := time.Duration(globalHTTPTimeoutMS) * time.Millisecond
eventRecorder := mgr.GetEventRecorderFor("keda-operator")
if err = (&kedacontrollers.ScaledObjectReconciler{
Client: mgr.GetClient(),
Scheme: mgr.GetScheme(),
GlobalHTTPTimeout: globalHTTPTimeout,
Recorder: eventRecorder,
}).SetupWithManager(mgr, controller.Options{MaxConcurrentReconciles: scaledObjectMaxReconciles}); err != nil {
setupLog.Error(err, "unable to create controller", "controller", "ScaledObject")
os.Exit(1)
}
if err = (&kedacontrollers.ScaledJobReconciler{
Client: mgr.GetClient(),
Scheme: mgr.GetScheme(),
GlobalHTTPTimeout: globalHTTPTimeout,
Recorder: eventRecorder,
}).SetupWithManager(mgr, controller.Options{MaxConcurrentReconciles: scaledJobMaxReconciles}); err != nil {
setupLog.Error(err, "unable to create controller", "controller", "ScaledJob")
os.Exit(1)
}
if err = (&kedacontrollers.TriggerAuthenticationReconciler{
Client: mgr.GetClient(),
Scheme: mgr.GetScheme(),
Recorder: eventRecorder,
}).SetupWithManager(mgr); err != nil {
setupLog.Error(err, "unable to create controller", "controller", "TriggerAuthentication")
os.Exit(1)
}
if err = (&kedacontrollers.ClusterTriggerAuthenticationReconciler{
Client: mgr.GetClient(),
Scheme: mgr.GetScheme(),
Recorder: eventRecorder,
}).SetupWithManager(mgr); err != nil {
setupLog.Error(err, "unable to create controller", "controller", "ClusterTriggerAuthentication")
os.Exit(1)
}
//+kubebuilder:scaffold:builder
if err := mgr.AddHealthzCheck("healthz", healthz.Ping); err != nil {
setupLog.Error(err, "unable to set up health check")
os.Exit(1)
}
if err := mgr.AddReadyzCheck("readyz", healthz.Ping); err != nil {
setupLog.Error(err, "unable to set up ready check")
os.Exit(1)
}
setupLog.Info("Starting manager")
setupLog.Info(fmt.Sprintf("KEDA Version: %s", version.Version))
setupLog.Info(fmt.Sprintf("Git Commit: %s", version.GitCommit))
setupLog.Info(fmt.Sprintf("Go Version: %s", runtime.Version()))
setupLog.Info(fmt.Sprintf("Go OS/Arch: %s/%s", runtime.GOOS, runtime.GOARCH))
if err := mgr.Start(ctrl.SetupSignalHandler()); err != nil {
setupLog.Error(err, "problem running manager")
os.Exit(1)
}
}