Skip to content

Latest commit

Β 

History

History
661 lines (490 loc) Β· 24.3 KB

BUILDING.md

File metadata and controls

661 lines (490 loc) Β· 24.3 KB

Building Node.js

Depending on what platform or features you need, the build process may differ. After you've built a binary, running the test suite to confirm that the binary works as intended is a good next step.

If you can reproduce a test failure, search for it in the Node.js issue tracker or file a new issue.

Table of Contents

Supported platforms

This list of supported platforms is current as of the branch/release to which it belongs.

Input

Node.js relies on V8 and libuv. We adopt a subset of their supported platforms.

Strategy

There are three support tiers:

  • Tier 1: These platforms represent the majority of Node.js users. The Node.js Build Working Group maintains infrastructure for full test coverage. Maintenance is supported by the Node.js core team. All commits to the Node.js repository are tested on multiple variants of these platforms. Test failures on tier 1 platforms will block releases.
  • Tier 2: These platforms represent smaller segments of the Node.js user base. The Node.js Build Working Group maintains infrastructure for full test coverage. Maintenance is supported by smaller groups or individuals within the Node.js core team, or the vendor of the platform itself. All commits to the Node.js repository are tested on multiple variants of these platforms where practical. Test failures on tier 2 platforms will block releases. Delays in release of binaries for these platforms are acceptable where necessary due to infrastructure concerns.
  • Experimental: May not compile or test suite may not pass. The core team does not create releases for these platforms. Test failures on experimental platforms do not block releases. Contributions to improve support for these platforms are welcome.

Platforms may move between tiers between major release lines. The table below will be updated to reflect those changes.

Platform list

Compiling and running Node.js is supported for a limited set of operating systems, architectures and libc versions. The table below lists the combinations that the core team has committed to supporting and the nature of that support as per the support tiers above. A list of supported compile toolchains is also supplied for tier 1 platforms.

For production applications, run Node.js on supported platforms only.

Node.js does not support a platform version if a vendor has expired support for it. In other words, Node.js does not support running on End-of-Life (EoL) platforms. This is true regardless of entries in the table below.

Operating System Architectures Versions Support Type Notes
GNU/Linux x64 kernel >= 3.10, glibc >= 2.17 Tier 1 e.g. Ubuntu 16.04 1, Debian 9, EL 7 2
GNU/Linux x64 kernel >= 3.10, musl >= 1.1.19 Experimental e.g. Alpine 3.8
GNU/Linux x86 kernel >= 3.10, glibc >= 2.17 Experimental Downgraded as of Node.js 10
GNU/Linux arm64 kernel >= 4.5, glibc >= 2.17 Tier 1 e.g. Ubuntu 16.04, Debian 9, EL 7 3
GNU/Linux armv7 kernel >= 4.14, glibc >= 2.24 Tier 1 e.g. Ubuntu 18.04, Debian 9
GNU/Linux armv6 kernel >= 4.14, glibc >= 2.24 Experimental Downgraded as of Node.js 12
GNU/Linux ppc64le >=power8 kernel >= 3.13.0, glibc >= 2.19 Tier 2 e.g. Ubuntu 16.04, EL 7
GNU/Linux s390x kernel >= 3.10.0, glibc >= 2.17 Tier 2 e.g. EL 7
Windows x64, x86 (WoW64) >= Windows 7/2008 R2/2012 R2 Tier 1 4,5
Windows x86 (native) >= Windows 7/2008 R2/2012 R2 Tier 1 (running) / Experimental (compiling) 6
Windows arm64 >= Windows 10 Experimental
macOS x64 >= 10.11 Tier 1
SmartOS x64 >= 18 Tier 2
AIX ppc64be >=power7 >= 7.1 TL05 Tier 2
FreeBSD x64 >= 11 Experimental Downgraded as of Node.js 12

1: GCC 6 is not provided on the base platform, users will need the Toolchain test builds PPA or similar to source a newer compiler.

2: GCC 6 is not provided on the base platform, users will need the devtoolset-6 or later to source a newer compiler.

3: Older kernel versions may work for ARM64, however the Node.js test infrastructure only tests >= 4.5.

4: On Windows, running Node.js in Windows terminal emulators like mintty requires the usage of winpty for the tty channels to work correctly (e.g. winpty node.exe script.js). In "Git bash" if you call the node shell alias (node without the .exe extension), winpty is used automatically.

5: The Windows Subsystem for Linux (WSL) is not directly supported, but the GNU/Linux build process and binaries should work. The community will only address issues that reproduce on native GNU/Linux systems. Issues that only reproduce on WSL should be reported in the WSL issue tracker. Running the Windows binary (node.exe) in WSL is not recommended. It will not work without workarounds such as stdio redirection.

6: Running Node.js on x86 Windows should work and binaries are provided. However, tests in our infrastructure only run on WoW64. Furthermore, compiling on x86 Windows is currently considered Experimental and may not be possible.

Supported toolchains

Depending on the host platform, the selection of toolchains may vary.

Operating System Compiler Versions
Linux GCC >= 6.3
Windows Visual Studio >= 2017 with the Windows 10 SDK on a 64-bit host
macOS Xcode >= 8 (Apple LLVM >= 8)

Official binary platforms and toolchains

Binaries at https://nodejs.org/download/release/ are produced on:

Binary package Platform and Toolchain
aix-ppc64 AIX 7.1 TL05 on PPC64BE with GCC 6
darwin-x64 (and .pkg) macOS 10.11, Xcode Command Line Tools 8 with -mmacosx-version-min=10.10
linux-arm64 CentOS 7 with devtoolset-6 / GCC 6
linux-armv7l Cross-compiled on Ubuntu 16.04 x64 with custom GCC toolchain
linux-ppc64le Ubuntu 14.04 with GCC 6
linux-s390x RHEL 7 with devtoolset-6 / GCC 6 7
linux-x64 CentOS 7 with devtoolset-6 / GCC 6 7
sunos-x64 SmartOS 18 with GCC 7
win-x64 and win-x86 Windows 2012 R2 (x64) with Visual Studio 2017

7: The Enterprise Linux devtoolset-6 allows us to compile binaries with GCC 6 but linked to the glibc and libstdc++ versions of the host platforms (CentOS 7 / RHEL 7). Therefore, binaries produced on these systems are compatible with glibc >= 2.17 and libstdc++ >= 6.0.20 (GLIBCXX_3.4.20). These are available on distributions natively supporting GCC 4.9, such as Ubuntu 14.04 and Debian 8.

OpenSSL asm support

OpenSSL-1.1.1 requires the following assembler version for use of asm support on x86_64 and ia32.

For use of AVX-512,

  • gas (GNU assembler) version 2.26 or higher
  • nasm version 2.11.8 or higher in Windows

Note that AVX-512 is disabled for Skylake-X by OpenSSL-1.1.1.

For use of AVX2,

  • gas (GNU assembler) version 2.23 or higher
  • Xcode version 5.0 or higher
  • llvm version 3.3 or higher
  • nasm version 2.10 or higher in Windows

Please refer to https://www.openssl.org/docs/man1.1.1/man3/OPENSSL_ia32cap.html for details.

If compiling without one of the above, use configure with the --openssl-no-asm flag. Otherwise, configure will fail.

Previous versions of this document

Supported platforms and toolchains change with each major version of Node.js. This document is only valid for the current major version of Node.js. Consult previous versions of this document for older versions of Node.js:

Building Node.js on supported platforms

The bootstrapping guide explains how to install all prerequisites.

Unix/macOS

Prerequisites

  • gcc and g++ >= 6.3 or newer, or
  • macOS: Xcode Command Line Tools >= 8
  • Python 2.7
    • Python 2.7 end of life is in 2019 so a transition to Python 3 is underway.
    • Python 3.5, 3.6, and 3.7 are experimental.
  • GNU Make 3.81 or newer

On macOS, install the Xcode Command Line Tools by running xcode-select --install. Alternatively, if you already have the full Xcode installed, you can find them under the menu Xcode -> Open Developer Tool -> More Developer Tools.... This step will install clang, clang++, and make.

If the path to your build directory contains a space, the build will likely fail.

On FreeBSD and OpenBSD, you may also need:

  • libexecinfo

Building Node.js

To build Node.js:

$ ./configure
$ make -j4

The -j4 option will cause make to run 4 simultaneous compilation jobs which may reduce build time. For more information, see the GNU Make Documentation.

Note that the above requires that python resolves to a supported version of Python. See Prerequisites.

After building, setting up firewall rules can avoid popups asking to accept incoming network connections when running tests.

Running the following script on macOS will add the firewall rules for the executable node in the out directory and the symbolic node link in the project's root directory.

$ sudo ./tools/macos-firewall.sh

Running Tests

To verify the build:

$ make test-only

At this point, you are ready to make code changes and re-run the tests.

If you are running tests before submitting a Pull Request, the recommended command is:

$ make -j4 test

make -j4 test does a full check on the codebase, including running linters and documentation tests.

Make sure the linter does not report any issues and that all tests pass. Please do not submit patches that fail either check.

If you want to run the linter without running tests, use make lint/vcbuild lint. It will run both JavaScript linting and C++ linting.

If you are updating tests and want to run tests in a single test file (e.g. test/parallel/test-stream2-transform.js):

$ python tools/test.py parallel/test-stream2-transform.js

You can execute the entire suite of tests for a given subsystem by providing the name of a subsystem:

$ python tools/test.py -J --mode=release child-process

If you want to check the other options, please refer to the help by using the --help option:

$ python tools/test.py --help

You can usually run tests directly with node:

$ ./node ./test/parallel/test-stream2-transform.js

Remember to recompile with make -j4 in between test runs if you change code in the lib or src directories.

The tests attempt to detect support for IPv6 and exclude IPv6 tests if appropriate. If your main interface has IPv6 addresses, then your loopback interface must also have '::1' enabled. For some default installations on Ubuntu that does not seem to be the case. To enable '::1' on the loopback interface on Ubuntu:

sudo sysctl -w net.ipv6.conf.lo.disable_ipv6=0

Running Coverage

It's good practice to ensure any code you add or change is covered by tests. You can do so by running the test suite with coverage enabled:

$ ./configure --coverage
$ make coverage

A detailed coverage report will be written to coverage/index.html for JavaScript coverage and to coverage/cxxcoverage.html for C++ coverage (if you only want to run the JavaScript tests then you do not need to run the first command ./configure --coverage).

Generating a test coverage report can take several minutes.

To collect coverage for a subset of tests you can set the CI_JS_SUITES and CI_NATIVE_SUITES variables (to run specific suites, e.g., child-process, in isolation, unset the opposing _SUITES variable):

$ CI_JS_SUITES=child-process CI_NATIVE_SUITES= make coverage

The above command executes tests for the child-process subsystem and outputs the resulting coverage report.

Alternatively, you can run make coverage-run-js, to execute JavaScript tests independently of the C++ test suite:

$ CI_JS_SUITES=fs CI_NATIVE_SUITES= make coverage-run-js

The make coverage command downloads some tools to the project root directory. To clean up after generating the coverage reports:

$ make coverage-clean

Building the documentation

To build the documentation:

This will build Node.js first (if necessary) and then use it to build the docs:

$ make doc

If you have an existing Node.js build, you can build just the docs with:

$ NODE=/path/to/node make doc-only

To read the documentation:

$ man doc/node.1

If you prefer to read the documentation in a browser, run the following after make doc is finished:

$ make docopen

This will open a browser with the documentation.

To test if Node.js was built correctly:

$ ./node -e "console.log('Hello from Node.js ' + process.version)"

To install this version of Node.js into a system directory:

$ [sudo] make install

Building a debug build

If you run into an issue where the information provided by the JS stack trace is not enough, or if you suspect the error happens outside of the JS VM, you can try to build a debug enabled binary:

$ ./configure --debug
$ make -j4

make with ./configure --debug generates two binaries, the regular release one in out/Release/node and a debug binary in out/Debug/node, only the release version is actually installed when you run make install.

To use the debug build with all the normal dependencies overwrite the release version in the install directory:

$ make install --prefix=/opt/node-debug/
$ cp -a -f out/Debug/node /opt/node-debug/node

When using the debug binary, core dumps will be generated in case of crashes. These core dumps are useful for debugging when provided with the corresponding original debug binary and system information.

Reading the core dump requires gdb built on the same platform the core dump was captured on (i.e. 64-bit gdb for node built on a 64-bit system, Linux gdb for node built on Linux) otherwise you will get errors like not in executable format: File format not recognized.

Example of generating a backtrace from the core dump:

$ gdb /opt/node-debug/node core.node.8.1535359906
$ backtrace

Windows

Prerequisites:

  • Python 2.7
  • The "Desktop development with C++" workload from Visual Studio 2017 or the "Visual C++ build tools" workload from the Build Tools, with the default optional components.
  • Basic Unix tools required for some tests, Git for Windows includes Git Bash and tools which can be included in the global PATH.
  • The NetWide Assembler, for OpenSSL assembler modules. If not installed in the default location, it needs to be manually added to PATH. A build with the openssl-no-asm option does not need this, nor does a build targeting ARM64 Windows.
  • Optional (to build the MSI): the WiX Toolset v3.11 and the Wix Toolset Visual Studio 2017 Extension.
  • Optional Requirements for compiling for Windows 10 on ARM (ARM64):
    • ARM64 Windows build machine
      • Due to a GYP limitation, this is required to run compiled code generation tools (like V8's builtins and mksnapshot tools)
    • Visual Studio 15.9.0 or newer
    • Visual Studio optional components
      • Visual C++ compilers and libraries for ARM64
      • Visual C++ ATL for ARM64
    • Windows 10 SDK 10.0.17763.0 or newer

If the path to your build directory contains a space or a non-ASCII character, the build will likely fail.

> .\vcbuild

To run the tests:

> .\vcbuild test

To test if Node.js was built correctly:

> Release\node -e "console.log('Hello from Node.js', process.version)"

Android/Android-based devices (e.g. Firefox OS)

Android is not a supported platform. Patches to improve the Android build are welcome. There is no testing on Android in the current continuous integration environment. The participation of people dedicated and determined to improve Android building, testing, and support is encouraged.

Be sure you have downloaded and extracted Android NDK before in a folder. Then run:

$ ./android-configure /path/to/your/android-ndk
$ make

Intl (ECMA-402) support

Intl support is enabled by default, with English data only.

Default: small-icu (English only) support

By default, only English data is included, but the full Intl (ECMA-402) APIs. It does not need to download any dependencies to function. You can add full data at runtime.

Build with full ICU support (all locales supported by ICU)

With the --download=all, this may download ICU if you don't have an ICU in deps/icu. (The embedded small-icu included in the default Node.js source does not include all locales.)

Unix/macOS
$ ./configure --with-intl=full-icu --download=all
Windows
> .\vcbuild full-icu download-all

Building without Intl support

The Intl object will not be available, nor some other APIs such as String.normalize.

Unix/macOS
$ ./configure --without-intl
Windows
> .\vcbuild without-intl

Use existing installed ICU (Unix/macOS only)

$ pkg-config --modversion icu-i18n && ./configure --with-intl=system-icu

If you are cross-compiling, your pkg-config must be able to supply a path that works for both your host and target environments.

Build with a specific ICU

You can find other ICU releases at the ICU homepage. Download the file named something like icu4c-**##.#**-src.tgz (or .zip).

To check the minimum recommended ICU, run ./configure --help and see the help for the --with-icu-source option. A warning will be printed during configuration if the ICU version is too old.

Unix/macOS

From an already-unpacked ICU:

$ ./configure --with-intl=[small-icu,full-icu] --with-icu-source=/path/to/icu

From a local ICU tarball:

$ ./configure --with-intl=[small-icu,full-icu] --with-icu-source=/path/to/icu.tgz

From a tarball URL:

$ ./configure --with-intl=full-icu --with-icu-source=http://url/to/icu.tgz
Windows

First unpack latest ICU to deps/icu icu4c-##.#-src.tgz (or .zip) as deps/icu (You'll have: deps/icu/source/...)

> .\vcbuild full-icu

Building Node.js with FIPS-compliant OpenSSL

The current version of Node.js does not support FIPS.

Building Node.js with external core modules

It is possible to specify one or more JavaScript text files to be bundled in the binary as built-in modules when building Node.js.

Unix/macOS

This command will make /root/myModule.js available via require('/root/myModule') and ./myModule2.js available via require('myModule2').

$ ./configure --link-module '/root/myModule.js' --link-module './myModule2.js'

Windows

To make ./myModule.js available via require('myModule') and ./myModule2.js available via require('myModule2'):

> .\vcbuild link-module './myModule.js' link-module './myModule2.js'

Note for downstream distributors of Node.js

The Node.js ecosystem is reliant on ABI compatibility within a major release. To maintain ABI compatibility it is required that distributed builds of Node.js be built against the same version of dependencies, or similar versions that do not break their ABI compatibility, as those released by Node.js for any given NODE_MODULE_VERSION (located in src/node_version.h).

When Node.js is built (with an intention to distribute) with an ABI incompatible with the official Node.js builds (e.g. using a ABI incompatible version of a dependency), please reserve and use a custom NODE_MODULE_VERSION by opening a pull request against the registry available at https://github.com/nodejs/node/blob/master/doc/abi_version_registry.json.