HPE DL360
- change power to always on
Run telegraf container:
sudo docker run -d --restart=always --network=host -v ./telegraf.d/telegraf.conf:/etc/telegraf/telegraf.conf docker.io/library/telegraf:1.31
lspci
root@dh2:~# lspci | grep BlueField-2
0f:00.0 Ethernet controller: Mellanox Technologies MT42822 BlueField-2 integrated ConnectX-6 Dx network controller (rev 01)
0f:00.1 Ethernet controller: Mellanox Technologies MT42822 BlueField-2 integrated ConnectX-6 Dx network controller (rev 01)
0f:00.2 DMA controller: Mellanox Technologies MT42822 BlueField-2 SoC Management Interface (rev 01)
serial
root@dh2:~# lspci -vvv -s 0f:00.2 | grep -A 11 "Vital Product Data"
Capabilities: [48] Vital Product Data
Product Name: BlueField-2 E-Series DPU 100GbE Dual-Port QSFP56, integrated BMC, Secure Boot Enabled, Crypto Enabled, 16GB on-board DDR, 1GbE OOB management, FHHL
Read-only fields:
[PN] Part number: MBF2M516C-CECOT
[EC] Engineering changes: A9
[V2] Vendor specific: MBF2M516C-CECOT
[SN] Serial number: MT2321XZ0KVX
[V3] Vendor specific: 1814c074ae05ee118000946daeb98570
[VA] Vendor specific: MLX:MN=MLNX:CSKU=V2:UUID=V3:PCI=V0:MODL=BF2M516C
[V0] Vendor specific: PCIeGen4 x16
[RV] Reserved: checksum good, 1 byte(s) reserved
End
rshim
root@dh2:~# cat /dev/rshim0/misc
DISPLAY_LEVEL 0 (0:basic, 1:advanced, 2:log)
BOOT_MODE 1 (0:rshim, 1:emmc, 2:emmc-boot-swap)
BOOT_TIMEOUT 150 (seconds)
DROP_MODE 0 (0:normal, 1:drop)
SW_RESET 0 (1: reset)
DEV_NAME pcie-0000:0f:00.2
DEV_INFO BlueField-2(Rev 1)
OPN_STR N/A
ssh over rshim
root@dh2:~# ifconfig tmfifo_net0 192.168.100.1/30 up
root@dh2:~# ping 192.168.100.2
root@dh2:~# ssh ubuntu@192.168.100.2
flush new BFB image
root@dh2:~# wget https://content.mellanox.com/BlueField/BFBs/Ubuntu22.04/bf-bundle-2.7.0-33_24.04_ubuntu-22.04_prod.bfb
root@dh2:~# cat bf-bundle-2.7.0-33_24.04_ubuntu-22.04_prod.bfb > /dev/rshim0/boot