Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Current Reference VREF #6

Open
feichtinger opened this issue Dec 5, 2016 · 0 comments
Open

Current Reference VREF #6

feichtinger opened this issue Dec 5, 2016 · 0 comments
Labels

Comments

@feichtinger
Copy link

The text saying "I_MAX=14"next to the voltage dividers for VREF (R7-R10) is wrong. Instead it is 11.6A.

U2 = U1R2/(R1+R2) != U1R2/R1
;)

Also I think that the cutoff frequency of the low pass should be a bit higher. With R9, R10=1k and C7, C8=100n the cutoff frequency is ~1.5 kHz.

For a 200 steps/rev motor turning with 2000 RPM (which is not too unrealistic I think) the step frequency (in our case: sine frequency) would be 6667 Hz. I would suggest to set C7 and C8 to 10nF instead of 100nF.

@pointhi pointhi added the bug label Dec 20, 2016
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
Projects
None yet
Development

No branches or pull requests

2 participants