A list of silas issues which should be split into new items, grouping where possible:
Overall
After the user has saved a change to the input, before the simulation button is pushed, plots should be grayed out or something, so that the user knows they are not up to date
Laser tab
remove the “from file” option for now
Change default num slice to >3, maybe 5
Add longitudinal representation of wavelength and frequency
Polarization: might be better to just say “linear” until later, maybe not even say anything at all if only one option choice (linear vertical vs linear horizontal would only matter if we had the crystal alignment information)
For current tau_fwhm, and soon-to-be-added tau_0, default to picoseconds for both
Change how we initialize from function? Place all slices at the same z?
Then on plots need to indicate the time of the slice relative to t_0, something like +-40ps
Clarify “number of gaussian sigma” to be in units of w, like +- # w (w=2*sigma)
Instead of “RMS waist size”, people use “Beam Size w”
Instead of sigma say rms or longitudinal standard deviations (or eliminate this option, set to ~6, require the last slice to be < 10% of peak, or could make +-2 or 3 FWHM_chirp)
Number of mesh points “in slice” is confusing
Laser reports
We would like the usual control over the plot limits
Why does the phase unwrapping look strange sometimes? (Maybe KW needs to play with the beta)
Thermal Transport tab
Crystal choice:
A crystal initialized on the Amplifier Tab
don’t let the user play with the pre-defined parameters like diameter (or if you do, the changes are reflected on the Amplifier Tab)
A crystal initialized on the thermal transport tab
All parameters adjustable
Clarify display:
Include the repetition rate and energy of the pump laser, as well as whether the crystal is pumped from left or right or both
Parameters below the equation need descriptions, update notations to:
T_0 notation is fine
δT notation is fine
ξ should be “w_p”
Add z_0 (half-length of crystal [cm])
Add alpha (inverse absorption length [1/cm])
Equation display clean up (current equation isn’t correct):
When selecting a different pump pulse profile (gaussian, higher order gaussian, top hat), the display should update what equation is shown
"gaussian": T = T_0 + dT * exp(-2*(x^2+y^2)/(wp^2)) * exp(-alpha * (z - z0))
"higher order gaussian" : T = T_0 + dT * exp(-((x^2+y^2)/(2*wp^2))^P) * exp(-alpha * (z - z0))
"top hat": If x^2+y^2 <= w_p, then T = T_0 + dT * alpha * exp(-alpha * (z - z0))/(1 - exp(2 * alpha * z0)); If x^2+y^2 > w_p, then T = T_0
Allow for choice between analytical calculation (known solution) or differential solve (FEniCS)
Crystals
n0 and n2, would like a FEniCS option and an Innocenzi option, if keep the boxes, need to label them with either position in crystal or corresponding crystal slice
Amplifier tab
Mirror: confusing currently
Clarify why it is there (to pass through the crystal from the other side)
Two cases:
No symmetry inversion (single flat mirror)
Flipped symmetry (two 45 degree mirrors called “folding mirror pair”)