Notifications
You must be signed in to change notification settings - Fork 4
/
rfc0044.txt
171 lines (121 loc) · 7.21 KB
/
rfc0044.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
Network Working Group A. Shoshani
Request for Comments: 44 R. Long
A. Landsberg
System Development Corporation
10 April 1970
Comments on NWG/RFC 33 and 36
Generally, we are satisfied with the suggestions for the new Host-
to-Host protocol. However, we think that a few refinements may be
helpful.
I. It seems that there are two cases of reconnection:
1. Reconnect from a socket in a local Host to another socket in the
local Host. This was referred to in RFC #33 as "switch". The
local sockets can belong to different processes (such as the
"Login" process switching a connection to another process just
created) or can belong to the same process (such as a process
that accepts calls for connections on a particular socket, and
after a connection is established switches to another of his
sockets).
2. Reconnect from a socket at a local Host to a socket in a foreign
Host.
We suggest separation of these two cases for the following reasons:
a) Reconnection in Case 1 is necessary and useful, while the
usefulness of Case 2 is still in doubt.
b) Case 1 is simple to implement (at least conceptually) while Case
2 involves an elaborate mechanism of commands because of the
asynchronous nature of the network (four out of nine commands
were suggested to handle Case 2 in RFC #36).
Thus we think that at least in the first usage of the Host-to-Host
protocol reconnection in Case 2 should be left out. An additional
system call (not a command) is therefore needed to permit Case 1,
which is SWITCH <socket 1> <socket 2>.
II. The CLOSE command as suggested in RFC #36 seems to be used for
two purposes: block a connection and abort a connection. To
avoid ambiguity it would be desirable to have two commands:
BLOCK and CLOSE. As suggested in RFC #36, the response for both
commands can be the SUSPEND command which acknowledges the
reception of BLOCK or CLOSE commands.
Shoshani, et al. [Page 1]
RFC 44 Comments on NWG/RFC 33 & 36 April 1970
III. After a connection has been established, we see no reason for
keeping the "foreign socket" in a local connection table. Since
there is a one-to-one correspondence between a link number of
the foreign Host and a foreign socket number, we can use the
link number in the commands. Thus, except for the RFC command,
all commands can use link numbers and therefore eliminate a 40-
bit foreign socket number in every entry of the connection table
(size being critical for some Hosts). We note that if
connections will be multiplexed over links as suggested in RFC
#38, then the foreign socket would be needed in the connection
table.
IV. In RFC#33 the term PORT was introduced. Although this is
private to every Host, we have a comment. If ports are used
such that there is a one-to-one correspondence between a port
for some user and a socket, then ports are completely redundant.
However, a Host may wish to multiplex ports over connections, in
which case an additional mechanism is needed.
To summarize the last four comments, we suggest that in the initial
version the following system calls and commands will be used (most of
them in RFC 33 and 36).
System Calls:
1) INITIATE <my socket> <your socket>
2) ACCEPT <my socket>
3) SWITCH <socket 1> <socket 2>
4) LISTEN <my socket>
5) CLOSE <my socket>
6) TRANSMIT <my socket> <address>
Commands:
Commands 0, 1, 3, 4 as in RFC #36 (pp.5) and in addition:
1) BLOCK: BLK <link>
2) CLOSE: CLS <link>
V. In addition to the above it seems necessary to decide on the
following issues one way or the other together with the first
version of the protocol (perhaps by setting a date for people to
express their preferences and decide accordingly). All of these
issues were mentioned in the meeting at UCLA on March 17, 1970,
but were put aside.
1. "Double padding" - when a message does not end on a word
boundary. Two possible solutions were mentioned:
a) Hosts provide their padding in addition to the IMP's
padding (double padding).
Shoshani, et al. [Page 2]
RFC 44 Comments on NWG/RFC 33 & 36 April 1970
b) Hosts make sure that all messages end on a word boundary
by shifting their messages (when necessary) and adjusting
the "marking" accordingly.
2. "Echoing" - there are three apparent possibilities:
a) Echoing
b) No echoing
c) Optional Echoing - possibly a bit in the "Leader" can be
used to designate this option.
3. "Code Conversion" - originally, BB&N suggested doing the
conversion in the IMPs using ASCII-8 as the common code.
This was rejected, mainly because of claims that ASCII-8 is
not large enough for some uses, such as graphics. Also
conversion in the IMPs may slow them down and take up space
which could be used for buffers. We feel that it is very
desirable to have a common code (even when the conversion is
not done by the IMPs), such that all incoming text messages
are in the same code and only one conversion table is needed.
Outgoing text messages should be converted into this common
code. Obviously, the option "no translation" should be
possible for the purpose of binary data or data that is not
representable in the common code. Since every known code can
be considered to be too restrictive for some purposes, we
suggest adopting a Network Common Code (NCC), and use all of
the 256 possible characters (for 8-bit code) to include the
"important" part of the union of the codes used throughout
the network.
VI. Our preference to the above issues is as follows:
a) "Double padding" -it turns out to be easy for us to get our
messages to be sent on a word boundary by shifting the leader
of a message (and adjusting the "marking" accordingly) rather
than the data. Thus we will prefer solution V.1.b).
b) "Echoing" - we prefer no echoing. We think that character
echoing should be managed locally.
c) "Code Conversion" we prefer a Network Common Code.
Initially, ASCII-8 can be used, and then expanded according
to the needs of the Network.
[ This RFC was put into machine readable form for entry ]
[ into the online RFC archives by Alison De La Cruz 12/00 ]
Shoshani, et al. [Page 3]