Wrong Junction/Short in Schematic #4

Closed
BluPhoenix opened this issue Jun 22, 2022 · 3 comments
Closed

Wrong Junction/Short in Schematic #4

BluPhoenix opened this issue Jun 22, 2022 · 3 comments

Comments

@BluPhoenix
Copy link

There is a Junction at the J1 connector shorting the A (Data) and D (VCC) inputs.
image

@tamanishi
Copy link
Owner

tamanishi commented Jun 25, 2022

Thanks for your comment.

I checked with Kicad 5 on my mac and it was not short-circuited. It wasn't connected in PCB Editor either.
(Check the images below).

And when I checked it in Kicad 6, it was shorted in Schematic Editor as you said but not connected in PCB Editor.

I guess the problem is caused by Kicad 6 or something.

Screenshot 2022-06-25 at 12 21 13

Screenshot 2022-06-25 at 12 24 42

Screenshot 2022-06-25 at 12 25 03

@tamanishi
Copy link
Owner

The Kicad developer says that in Kicad 6, this is "as-designed" behavior. Sorry for the inconvenience, please use Kicad 5 for a while.
https://gitlab.com/kicad/code/kicad/-/issues/10235
https://gitlab.com/kicad/code/kicad/-/issues/11760
https://gitlab.com/kicad/code/kicad/-/issues/11831

@BluPhoenix
Copy link
Author

Hi thanks for the quick replies. Kind of weird of KiCAD to introduce an update that potentially changes connectivity.
For myself I'd simply move the VCC symbol a bit and remove the junction and then use KiCAD 6.

Just wanted to inform people of this issue before someone unknowingly updates the PCB Components and nets from schematic and doesn't notice this.