MQTT

Overall

The mqtt prefix is configurable within AquaMQTT/include/config/ExampleConfiguration.h:

constexpr char     mqttPrefix[]     = "prefix/";

Using the prefix, the $root topic is created, which is $prefix/aquamqtt/ and used by all of the below messages.

Publish Topics

AquaMQTT / Statistics

Value MQTT Topic Format Unit Other Information
Last Will $root/stats/lwlState Enum ONLINE, OFFLINE -- retained
OperationMode $root/stats/aquamqttMode Enum LISTENER, MITM
Active Overrides (HMI) $root/stats/activeOverrides json Active Overrides are flagged either with 1 (overridden) or 0 (not overridden) Example Payload: { "operationMode": 0, "operationType": 0, "waterTempTarget": 0, "heatingElementEnabled": 0, "emergencyModeEnabled": 0, "configInstallation": 0 , "time/date": 1 }
Active Overrides (MAIN) $root/stats/activeOverridesMain json Active Overrides are flagged either with 1 (overridden) or 0 (not overridden) Example Payload: { "statePV": 1, "stateSolar": 1 }
Override Modes $root/stats/overrideMode Enum STANDARD, PV HP, PV HE or PV BOOST. See README-PV.md for additional information.
Flag PV heat pump $root/stats/flagPVModeHeatPump bool Status of the pv heat pump flag. See README-PV.md for additional information.
Flag PV heat element $root/stats/flagPVModeHeatElement bool Status of the pv heat element flag. See README-PV.md for additional information.
IP Address $root/stats/ipAddress string e.g. 192.168.188.62
RSSI $root/stats/rssiDb int dB
Messages OK $root/stats/$channel/msgHandled uint64
Messages IGNORED $root/stats/$channel/msgUnhandled uint64
Messages CRC NOK $root/stats/$channel/msgCRCNOK uint64
Dropped Bytes $root/stats/$channel/droppedBytes uint64

$channel is either hmi and main or listener depending on the AquaMQTT operation mode.

HMI Message

Value MQTT Topic Format Unit Other Information
Target Water Temperature $root/hmi/waterTempTarget float °C
Operation Mode $root/hmi/operationMode Enum AUTO, MAN ECO ON, MAN ECO OFF, BOOST, ABSENCE
Operation Type $root/hmi/operationType Enum TIME WINDOW, ALWAYS ON
Operation Time Window A $root/hmi/timerWindowA string e.g. 22:00-06:00
Operation Time Window B $root/hmi/timerWindowB string e.g. 04:00-08:00
Current Time $root/hmi/time string e.g 09:11:59
Current Date $root/hmi/date string e.g 07.09.2023
Emergency Mode Enabled $root/hmi/emergencyMode bool
Heating Element Enabled $root/hmi/heatingElementEnabled bool
Anti-Legionella Mode $root/hmi/antiLegionellaPerMonth uint8 0 (off), 1 (once per month), etc
Configuration AirDuct $root/hmi/configAirduct Enum INT/INT, INT/EXT, EXT/EXT
Configuration FanExhaust $root/hmi/configFanExhaust Enum STOP, LOW SPEED, HIGH SPEED Note: Only available in AirDuct mode INT/EXT
Configuration Installation $root/hmi/configInstallation Enum HEAT PUMP ONLY, BOILER BACKUP / HEAT PUMP PRIORITY, BOILER BACKUP / HEAT PUMP OPTIMIZED, BOILER BACKUP / BOILER OPTIMIZED, BOILER BACKUP / BOILER PRIORITY, HEAT PUMP AND SOLAR BACKUP
HMI SetupState $root/hmi/setupState Enum OK, PARTIAL RESET, FACTORY RESET
PV Input Activated $root/hmi/pvInputActivated bool
Raw Message (Debug Mode Only) $root/hmi/debug string

Main Message

Value MQTT Topic Format Unit Other Information
Present Error Code $root/main/errorCode uint8 0 if there is no present error, else the error-code
Current Water Temperature $root/main/waterTemp float °C
Supply Air Temperature $root/main/supplyAirTemp float °C
Lower Evaporator Air Temperature $root/main/evaporatorAirTempLower float °C
Upper Evaporator Air Temperature $root/main/evaporatorAirTemp float °C
Fan Speed $root/main/fanSpeed uint16 rpm Removed since the message contained the pwm level and no rpm value.
Fan-Level PWM $root/main/fanPWM float %
State: Fan On/Off $root/main/stateFan bool
State: Heatpump On/Off $root/main/stateHeatpump bool
State: Heating Element On/Off $root/main/stateElement bool
State: Boiler Backup On/Off $root/main/stateExtBoiler bool
State: Defrost On/Off $root/main/stateDefrost bool
State: Solar Input Signal Detected $root/main/stateSolar bool
State: PV Input Signal Detected $root/main/statePV bool
Setting: 1st Fan-Level PWM $root/main/settingPWM_1 uint8 %
Setting: 2nd Fan-Level PWM $root/main/settingPWM_2 uint8 %
Setting: 3rd Fan-Level PWM $root/main/settingPWM_3 uint8 %
Setting: Min. Target Temp $root/main/settingMinTargetTemp uint8 °C
Setting: Min. Anti-Legionella Temp $root/main/settingMinLegionellaTemp uint8 °C
Setting: Wattage Heat Element $root/main/settingWattageElement uint16 W
Setting: Boiler Capacity $root/main/settingBoilerCapacity uint16 l
Setting: Boiler Brand $root/main/settingBoilerBrand Enum Atlantic, Thermor, Sauter, No Name
Capability: Has Heat Exchanger $root/main/capabilityHeatExchanger bool
Capability: Has Circulation $root/main/capabilityCirculation bool
Capability: Has PV-Input $root/main/capabilityPVInput bool
Capability: Has Communication $root/main/capabilityCommunication bool
Capability: Has Anti-Dry-Heating $root/main/capabilityAntiDryHeating bool
Raw Message (Debug Mode Only) $root/main/debug string

Energy Message

Value MQTT Topic Format Unit Other Information
Total Heatpump Hours $root/energy/totalHeatpumpHours uint32 h retained
Total Heating Element Hours $root/energy/totalHeatingElemHours uint32 h retained
Total Hours $root/energy/totalHours uint32 h retained
Total Energy $root/energy/totalEnergyWh uint64 Wh
Total Water Production $root/energy/totalWaterProduction uint16 l Note: Expected to wrap-around at UINT16_MAX
Current Power Heatpump $root/energy/powerHeatpump uint16 W Note: It is possible to define an additional custom mqtt topic for this attribute within Configuration.h
Current Power Heating Element $root/energy/powerHeatingElem uint16 W Note: It is possible to define an additional custom mqtt topic for this attribute within Configuration.h
Current Power Total $root/energy/powerTotal uint16 W
Raw Message (Debug Mode Only) $root/energy/debug string

Error Messages

Collected Error Messages are provided to mqtt, the latest/recent occurred error is always error number == 1. The values within the message reflect the state when the error has been created.

Value MQTT Topic Format Unit Other Information
Error Number $root/error/%requestId/errorNumber uint8
Error Code $root/error/%requestId/errorCode uint8
Date $root/error/%requestId/date string e.g. 25.5.2024
Time (hh:ss) $root/error/%requestId/time string e.g. 21:29
Water Temperature $root/error/%requestId/waterTemp float
Lower Evaporator Air Temperature $root/error/%requestId/evaporatorAirTempLower float
Upper Evaporator Air Temperature $root/error/%requestId/evaporatorAirTemp float
Fan-Level PWM $root/error/%requestId/fanPWM uint8 %
Total Heatpump Hours $root/error/%requestId/totalHeatpumpHours uint16
Total Heating Element Hours $root/error/%requestId/totalHeatingElemHours uint16
Raw Message (Debug Mode Only) $root/error/debug string

Subscribe Topics

Using this topics you may override the HMI Controller in AquaMQTT OperationMode Man-In-The-Middle. Currently these are the only ones implemented. If you need more overrides, feel free to raise an issue or even provide an PR.

Value / Action MQTT Topic Format Unit Example Payload Other Information
Target Water Temperature $root/ctrl/waterTempTarget float °C "55.0" Overrides the water temperature target: Allowed range is from 20°C to 62°C.
Operation Mode $root/ctrl/operationMode Enum "BOOST" Overrides the operation mode, may affect the waterTempTarget. For example BOOST and ABSENCE will automatically set the waterTempTarget accordingly.
Operation Type $root/ctrl/operationType Enum "ALWAYS ON" Overrides the operation type
Installation Config $root/ctrl/configInstallation Enum "HEAT PUMP ONLY", "BOILER BACKUP / HEAT PUMP PRIORITY"", "..." Overrides the installation config
AirDuct Config $root/ctrl/configAirduct Enum "INT/INT", "INT/EXT", "EXT/EXT" Overrides the air duct config
FanExhaust Config $root/ctrl/configFanExhaust Enum "STOP", "LOW SPEED", "HIGH SPEED" Overrides the fan exhaust config. Note: This will only have an effect in AirDuct mode INT/EXT

| Enable or disable heating element | $root/ctrl/heatingElementEnabled | bool | | "1" | Allow the DHW heat pump to use the heating element if needed. Sanity: It is not possible to disable the heating element in case emergency mode is enabled. | | Enable or disable emergency mode | $root/ctrl/emergencyModeEnabled | bool | | "0" | Forces the DHW heat pump to use only the heating element. Sanity: it is not possible to enable emergency mode if heating element has been disabled. | | Set PV Mode Heat Pump Flag | $root/ctrl/flagPVModeHeatPump | bool | | "1" | See README-PV.md additional information. Note: It is possible to define an additional custom mqtt topic for this attribute within Configuration.h | | Set PV Mode Heat Element Flag | $root/ctrl/flagPVModeHeatElement | bool | | "1" | See README-PV.md for additional information. Note: It is possible to define an additional custom mqtt topic for this attribute within Configuration.h | | Reset Overrides | $root/ctrl/reset | Void | | | Removes all previous set overrides. |

Note: Calling a ctrl topic with an empty payload "" will reset individual override.