Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Temporarily work around issue #382 #385

Closed

Conversation

whitequark
Copy link
Member

Display a better message so that people don't think the units we already have with firmware we cannot change (I think @esden is not able to reflash them anymore) are faulty in any way.

@esden
Copy link
Member

esden commented Aug 4, 2023

I have not packed them into boxes yet. I can still reflash all the early birds.

@whitequark
Copy link
Member Author

Got it. Let's see if @VioletEternity is able to narrow down the cause of this problem.

@VioletEternity
Copy link
Contributor

When the device is in a failed state, running a command now results in:

>glasgow voltage
E: glasgow.cli: failed to enumerate a device; try unplugging it and plugging it back in

>

After following the instructions the command does succeed. (Although I had to reset it twice just now.)

@whitequark
Copy link
Member Author

Closed in favor of #395.

@whitequark whitequark closed this Sep 20, 2023
@whitequark whitequark deleted the workaround-issue-382 branch July 21, 2024 20:42
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment