IKEA STARKVIND should honer FanModeSequence #3277

Merged
merged 2 commits into from
Nov 4, 2021
Merged

Conversation

sjorge
Copy link
Sponsor Contributor

@sjorge sjorge commented Nov 3, 2021

I noticed that FanModeSequence returns 0x02 for the STARKVIND, according to ZCL:
0x02 Low/Med/High/Auto

I noticed that FanModeSequence returns 0x02 for the STARKVIND, according to ZCL:
0x02 Low/Med/High/Auto
@sjorge
Copy link
Sponsor Contributor Author

sjorge commented Nov 3, 2021

OK this might need a follow up, a side effect of the expose is that is also exposes fan_state which is ON or OFF... but that of course doesn't work because 'on' is not a supported fan mode for this device. Using the physical buttons seems to turn it on in 'auto' mode.

EDIT: I have a idea for a nice way to fix this, let me implement and test it.

@sjorge
Copy link
Sponsor Contributor Author

sjorge commented Nov 3, 2021

Setting fan_state=ON now matches what happens when you physically push the hardware button (which defaults to 'auto' as wel)

@sjorge sjorge changed the title Update fan_mode range based on FanModeSequence for IKEA STARKVIND IKEA STARKVIND should honer FanModeSequence Nov 3, 2021
@Koenkk
Copy link
Owner

Koenkk commented Nov 4, 2021

Thanks!

@Koenkk Koenkk merged commit 67d503a into Koenkk:master Nov 4, 2021