Fix warning mode for Bitron AV2010/24A #3353

Merged
merged 1 commit into from
Nov 15, 2021

Conversation

muellermartin
Copy link
Contributor

The Bitron AV2010/24A smoke detector behaves not as expected when mode,
level and strobe are set for the warning capability.
When the field order is flipped in the packet structure, the behaviour
is as expected (as far as the options are supported).

This patch has been tested with a Bitron AV2010/24A smoke detector.

Related to #2988 and Koenkk/zigbee2mqtt#8310

The Bitron AV2010/24A smoke detector behaves not as expected when mode,
level and strobe are set for the warning capability.
When the field order is flipped in the packet structure, the behaviour
is as expected (as far as the options are supported).

Related to Koenkk#2988 and Koenkk/zigbee2mqtt#8310