Clarify send/receiving data for MDI
Browse files Browse the repository at this point in the history
  • Loading branch information
janash committed May 8, 2024
1 parent e714cf4 commit d78a2ee
Showing 1 changed file with 14 additions and 3 deletions.
17 changes: 14 additions & 3 deletions driver_tutorial.md
Original file line number Diff line number Diff line change
Expand Up @@ -315,10 +315,19 @@ When using MDI, we retrieve data from the engine by sending a command to the eng
The first command we use is the `mdi.MDI_Send_Command` function.
The argument to this function is the command to send and the engine we would like to send the command to.
When using `MDI_Send_Command`, we use `<` to tell the engine to send data to the driver, and `>` to tell the driver to send data to the engine.

For example, to get the number of atoms in the system, we first call `mdi.MDI_Send_Command("<NATOMS", lammps)` to tell LAMMPS to send the number of atoms.
Then, we call `mdi.MDI_Recv` to receive the data.

After we have sent the command to the engine, we have to retrieve the data.
This is done with the `mdi.MDI_Recv` function.
When using `mdi.MDI_Recv`, we have to tell MDI how many values we expect to get back and the data type for the value or values we expect to receive.
They syntax is

```python
mdi.MDI_Recv(EXPECTED_NUMBER_OF_VALUES, DATA_TYPE, ENGINE_COMMUNICATOR)
```

The expected data types are defined in the MDI library.
For example, `mdi.MDI_INT` is the data type for an integer, and `mdi.MDI_DOUBLE` is the data type for a double (decimal) value.

Add the following code to the `# Perform the simulation` section to get the number of atoms in the system:

Expand All @@ -336,14 +345,16 @@ print(f"The number of atoms in the system is {natoms}.")
```
````

These set of commands first tells LAMMPS to send the number of atoms in the system (`mdi.MDI_Send_Command("<NATOMS", lammps)`). After that, we receive the number of atoms from LAMMPS. Using `mdi.MDI_Recv`, we tell lammps we are expecting `1` value for `natoms` and that its data type is an integer.
These set of commands first tells LAMMPS to send the number of atoms in the system (`mdi.MDI_Send_Command("<NATOMS", lammps)`).
After that, we receive the number of atoms from LAMMPS. Using `mdi.MDI_Recv`, we tell lammps we are expecting `1` value for `natoms` and that its data type is an integer.

````{admonition} Check Your Understanding
:class: exercise
Retrieve the box vectors from LAMMPS and print it to the screen.
The command to get the box vectors is `<CELL`. You expect this to contain 9 values (3 for each dimension).
The data type we expect is an mdi.MDI_DOUBLE.
```{admonition} Solution
:class: solution dropdown
Expand Down

0 comments on commit d78a2ee