Notifications
You must be signed in to change notification settings - Fork 1.1k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Mavic 3M Support #1771
Mavic 3M Support #1771
Conversation
One issue with this approach, however, is that the RGB sensor and the MS sensor have different sensitivities / store different tags. I don't know how to reconcile these differences when radiometric calibration is turned on (often the use case with MS images). I'm going to leave this RGB+MS code in the https://github.com/pierotofy/ODM/tree/mavic3mrgbms branch. I think it's fundamentally difficult to get accurate measurements using different sensors. I think the workflow with this drone is to process the MS and RGB data separately and get two orthophotos. This PR will then add support for processing MS datasets only on the M3M, which is still a nice improvement. |
Informed of the consequences or not, it's a very common request to be able process RGB and multispectral images together. Does it make sense to allow processing together in main branch ODM if no radiometric calibration is applied? |
Related: what kind of testing do you want? I've got a small pile of datasets now, although I may need to revert to some folks for different sharing links or smaller datasets. |
Does other software do it? Aside from the additional complexity that leaving this code in the main branch leads, I'd argue there's little value in having a combined orthophoto with substantially different units. You can't make meaningful measurements from it. |
Would be nice to test a few Mavic 3M datasets, or other MS datasets from other drones that have had issues with misalignment (especially if the images were > 1280 px). This PR should improve processing of those. |
I would add, if someone can point a way to get normalized reflectance values between MS and RGB sensors, I'd happily bring the feature in main. |
Probably the jetlag, but I'm kind of unclear what the issue is between RGB and MS: is this 8-bit vs. 16-bit, or DN vs. reflectance, or mixing RGB + R + G + RE + NIR or R + G + (B from RGB) + RE + NIR in a mixture of DN vs. reflectance? It's not uncommon in the remote sensing world to mix different DN depths in the same image stack. MODIS was the first major sensor to do this. From a downstream science perspective alignment at the sensor level would be much preferable to 2 orthophotos (short of alignment at the sensor and adding the complexity of delivering two payloads), which is why folks are asking for everything together. Not sure what other products do. Don't really care (much). In short, I don't see any issue in mixing bit depth, that's normal and useful, (if that's the issue), but mixing DN and reflectance probably doesn't make sense. Edit: from a science applications perspective, best possible output is: RGB + R + G + RE + NIR, with no place no band swapping. Preserves RGB resolution, doesn't mix bit depth on RGB, allows for fully aligned full set of products and optional post-processing of MS bands. |
DN is not a problem. (That's what you can get with the code now in https://github.com/pierotofy/ODM/tree/mavic3mrgbms) Reflectance is. You're going to get very different scales between RGB and MS. Problem: people will upload the images in WebODM, select "Multispectral" and will get the wrong indices calculations in the plant health tab. |
Ah gotcha on the mixing RGB and MS bands. Point of clarification: there's calibration happening for both sets of bands, but the ranges don't match? That seems (broadly) solvable (not sure how to handle the blue, but have a hunch or two).
https://crankyserver.com/public/task/c2d619f3-1502-403c-b014-01ce2cef0207/map/?t=orthophoto
|
Raw images values (0-255 for RGB), (0-65535 for MS) need to go through Maybe there's some way to reconcile the two, but even DJI's own manual seems to hint at the fact that the MS bands are to be treated separately from RGB for processing. https://dl.djicdn.com/downloads/DJI_Mavic_3_Enterprise/20230829/Mavic_3M_Image_Processing_Guide_EN.pdf |
edit: tested wrong for this branch. Never-the-less, this got merged while I was in the midst of testing. |
Why publish homography data and embed it in the sensor exif specific to the sensor if they aren't meant to be used together? Should they be used in band math together? Probably not. Are they useful in aligned datasets together: yes. If I had to guess, the values differ because the sensors are different. They shouldn't have the same reflectance values because the R in the RGB doesn't have the same spectral response function as the R from the MS bands. With different spectral response curves, the value for reflectance will be different between the same names for channels. This is normal. Where it might become a problem would be in indices as you highlight. In the absence of spectral response curves published by DJI and a spectral resampling approach to apply those curves to ensure the bands match between RGB and MS, there is no robust, non-heuristic way to make them have the same range of values. That doesn't mean the RGB values are wrong, simply incommensurate. There are ways to work around this heuristically, but that's another conversation. So: no (robust, non-heuristic) way to make them match, but also IMO no reason to make them match -- they aren't the same band, they are just named similarly. Unless I'm missing something (likely) I'm still not clear why we aren't:
I could see an argument for not building an RGB-R-RE-G-NIR output to avoid adding logic to WebODM to handle the indices correctly, but other than support issues in WebODM, IMO, RGB-R-RE-G-NIR would be appropriate and what is expected from this sensor. Sans spectral response sampling, R(GB) will never match R, nor should it. And users are right to expect that they should be able to process all bands together. That's the implicit promise of the sensor. Example use case: use MS data to train CNN on RGB data, requiring good band alignment between RGB and MS bands. I'm doing this now and will use https://github.com/pierotofy/ODM/tree/mavic3mrgbms unless / until the functionality gets merged into master (and thanks for putting that branch together!). But I do worry if it sits in a feature branch, the functionality will go long periods untested and become unmaintained. |
Thanks for testing! Glad the alignment worked. From a technical point of view, generating and handling a RGB-R-RE-G-NIR orthophoto is non-trivial, both in ODM and WebODM. |
For clarification: is this branch supposed to align RGB and MS? Tested both with radiometric-calibration: camera and without:
That's my hunch on WebODM. In what way for ODM?
Always. Testing on one more full size dataset and then call it. |
Edit: the
Mostly the modifications to https://github.com/OpenDroneMap/odm_orthophoto to accomodate for the mix of multi-band textures (RGB) and single band images (MS) with overlapping band names (R, R_MS, etc.). I wouldn't look forward to make those. |
Cool. I'll poke at it. It may just make sense for me to run a pre-alignment of the bands and maybe add a script to contrib, but let's see if I can figure out what's happening with the branch first.
Ah, yup. Makes sense. No build-in expectation multiple of the "same" bands, and the bands need tracked and correctly identified for orthophoto output requiring a fair amount of custom logic. It'll be interesting to see if other sensors show up with similar characteristics, but that does seem like a high LOE for a single sensor. Add to that the headache that introduces for WebODM... and yup. Thanks for the extensive explainer (and of course the homography fix!). I'll ping the community thread now that things a merged so folks can test. |
Interesting. Just to confirm @ehallein: the red band is offset but the rest align with each other? |
correct. I'll do some more tests on other datasets tomorrow and see they go. |
hi all, i am a user of webODM and the company i am working for has purchased a Mavic3M. the drone has been used for the last month or so every week. We have a good time series database for 6 areas of study. auto-boundary: true, optimize-disk-space: true, pc-quality: ultra, radiometric-calibration: camera+sun, texturing-skip-global-seam-leveling: true Note that i tried the same above but with radiometric-calibration: camera and i obtain similar reflectance values. The processed images show very low reflectance values as you can see from the screenshot below (i split the bands in QGIS just to show the value of reflectance for each band). Is anyone able to tell me if these values are trustworthy? For instance, if i calculate NDVI i get values in the expected threshold (-1 to 1). So, apparently the NDVI comes out OK but i wanted to be reassured that such a low reflectance values are "correct". Thanks a lot in advance |
@ehallein, have you been able to replicate the red band alignment issue with other datasets? |
So far it's fixed from my testing, and does better than DJI's own software. I suspect it will never be pixel perfect due minor differences in lenses etc. |
Cool thanks. Looks like you already commented on the issue, so thanks for the double comment! |
@pierotofy is this expected to work on the GPU build? I tried running it with the multispectral tiffs on GPU and it came out as a mess (the RGB jpegs work fine). |
It should, it's the same code. |
Never mind, I was doing something silly. Works fine! |
hello all, i thank you all for the effort you are making to support the Mavic3M. Is there any news on the radiometric calibration of the multispectral images? In my previous comment i mentioned that i manage with the band alignement but the radiometric calibration is still an issue. |
Continuing the work from #1740
I finally got good results on a test dataset. The main cause of the misalignment issue on the Mavic 3M was due to a fault in how the homography was computed. The images are > 1280 pixels, which was causing the calculations to be way off. The homography needed to be rescaled for it to make sense.
This should then fix alignment for other sensors as well.
Furthermore, the RGB images were dewarped, but didn't match the size of the multispectral bands. This was causing issues during alignment.
It should now be possible to process RGB+multispectral, or multispectral data alone from the Mavic 3M.
RGB
RNirRe