signal-to-noise separated into ratio and noise in IsoFiltR #594

Merged
merged 4 commits into from
Oct 21, 2024

Conversation

KristinaGomoryova
Copy link
Collaborator

Signal-to-ratio parameter is now separated into kmdn * SN_ratio similarly as it's done in other functions (e.g. MFAssign).

closes #588

@hechth
Copy link
Member

hechth commented Oct 17, 2024

@KristinaGomoryova is this the only tool where this was still combined? Or aren't there more of them yet?

@KristinaGomoryova
Copy link
Collaborator Author

Well, this is somewhat related RECETOX/MFAssignR#63

@hechth
Copy link
Member

hechth commented Oct 21, 2024

Please make the same changes also to the SNplot tool where we currently have the cutoff value as a single parameter.

@KristinaGomoryova
Copy link
Collaborator Author

Please make the same changes also to the SNplot tool where we currently have the cutoff value as a single parameter.

Resolved in cc5048d

@hechth hechth merged commit 4bd188e into RECETOX:master Oct 21, 2024
13 checks passed