Open Source MTConnect® Agent and Adapter for Haas CNC Machines using Ethernet or RS-232
This supports the basic data collection variables available using setting 143 on Haas machines described in the link below:
http://diy.haascnc.com/data-collection-using-rs-232-port-0
- Add the ability to add Q600 variables to the configuration file
- Better error management
<?xml version="1.0" encoding="utf-8" ?>
<Configuration>
<Device>
<!-- Device Name used in Devices.xml file for MTConnect® Agent's schema -->
<DeviceName>Haas_Device</DeviceName>
<!-- Port to communicate with MTConnect Agent -->
<Port>7885</Port>
<!-- Adapter heartbeat -->
<Heartbeat>1000</Heartbeat>
<!-- Ethernet settings to communicate with the Haas machine -->
<EthernetServer>localhost</EthernetServer>
<EthernetPort>5051</EthernetPort>
</Device>
</Configuration>
<?xml version="1.0" encoding="utf-8" ?>
<Configuration>
<Device>
<!-- Device Name used in Devices.xml file for MTConnect® Agent's schema -->
<DeviceName>Haas_Device</DeviceName>
<!-- Port to communicate with MTConnect Agent -->
<Port>7885</Port>
<!-- Adapter heartbeat -->
<Heartbeat>1000</Heartbeat>
<!-- COM Port to communicate with the Haas machine -->
<COMPort>COM3</COMPort>
</Device>