3 changes: 2 additions & 1 deletion addons/medical_status/functions/fnc_getBloodLoss.sqf
Original file line number Diff line number Diff line change
Expand Up @@ -21,9 +21,10 @@ private _woundBleeding = GET_WOUND_BLEEDING(_unit);
if (_woundBleeding == 0) exitWith {0};

private _cardiacOutput = [_unit] call FUNC(getCardiacOutput);
private _resistance = _unit getVariable [VAR_PERIPH_RES, DEFAULT_PERIPH_RES]; // can use value directly since this is sum of default and adjustments

// even if heart stops blood will still flow slowly (gravity)
private _bloodLoss = (_woundBleeding * (_cardiacOutput max CARDIAC_OUTPUT_MIN) * EGVAR(medical,bleedingCoefficient));
private _bloodLoss = (_woundBleeding * (_cardiacOutput max CARDIAC_OUTPUT_MIN) * (DEFAULT_PERIPH_RES / _resistance) * EGVAR(medical,bleedingCoefficient));

private _eventArgs = [_unit, _bloodLoss]; // Pass by reference