Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

fix(misconf): check if property is not nil before conversion #7578

Merged
merged 1 commit into from
Oct 17, 2024

Conversation

nikpivkin
Copy link
Contributor

@nikpivkin nikpivkin commented Sep 23, 2024

Description

This PR fixes the panic of trying to convert a property that is missing from the template.

Template:

---
AWSTemplateFormatVersion: 2010-09-09
Description: Godd example of excessive ports
Resources: 
  NetworkACL:
    Type: AWS::EC2::NetworkAcl
  Rule:
    Type: AWS::EC2::NetworkAclEntry
    Properties:
      NetworkAclId:
        Ref: NetworkACL

Output:

trivy conf main.yaml
2024-09-23T23:28:45+06:00       INFO    [misconfig] Misconfiguration scanning is enabled
panic: runtime error: invalid memory address or nil pointer dereference
[signal SIGSEGV: segmentation violation code=0x2 addr=0xe0 pc=0x10363f0c4]

goroutine 1 [running]:
github.com/aquasecurity/trivy/pkg/iac/scanners/cloudformation/parser.(*Property).Type(...)
        /home/runner/work/trivy/trivy/pkg/iac/scanners/cloudformation/parser/property.go:108
github.com/aquasecurity/trivy/pkg/iac/scanners/cloudformation/parser.(*Property).ConvertTo(0x0, {0x1053ac0f7, 0x3})
        /home/runner/work/trivy/trivy/pkg/iac/scanners/cloudformation/parser/property_conversion.go:66 +0x24
github.com/aquasecurity/trivy/pkg/iac/adapters/cloudformation/aws/ec2.getRules({0x1400491f8e0, 0xa}, {{0x1400491f810, 0x9}, {0x140039bd080, 0xb, 0xb}, {0x1053addf7, 0x4}, {0x0, ...}, ...})
        /home/runner/work/trivy/trivy/pkg/iac/adapters/cloudformation/aws/ec2/nacl.go:68 +0x1638

Checklist

  • I've read the guidelines for contributing to this repository.
  • I've followed the conventions in the PR title.
  • I've added tests that prove my fix is effective or that my feature works.
  • I've updated the documentation with the relevant information (if needed).
  • I've added usage information (if the PR introduces new options)
  • I've included a "before" and "after" example to the description (if the PR is a user interface change).

Signed-off-by: nikpivkin <nikita.pivkin@smartforce.io>
@nikpivkin nikpivkin marked this pull request as ready for review September 23, 2024 17:30
@nikpivkin nikpivkin requested a review from simar7 as a code owner September 23, 2024 17:30
@simar7 simar7 added this pull request to the merge queue Sep 24, 2024
@github-merge-queue github-merge-queue bot removed this pull request from the merge queue due to failed status checks Sep 24, 2024
@simar7 simar7 added this pull request to the merge queue Oct 17, 2024
@github-merge-queue github-merge-queue bot removed this pull request from the merge queue due to failed status checks Oct 17, 2024
@nikpivkin nikpivkin added this pull request to the merge queue Oct 17, 2024
Merged via the queue into aquasecurity:main with commit c8c14d3 Oct 17, 2024
14 checks passed
@nikpivkin nikpivkin deleted the cf-prop branch October 17, 2024 04:02
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging this pull request may close these issues.

2 participants