[FIX] consistent CoordinateSystem fields for ephys #641
Conversation
Co-authored-by: Richard Höchenberger <richard.hoechenberger@gmail.com>
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Overall the text looks reasonable. Main suggestion is indicating the conditional requirement level in the Requirement level columns. I stopped manually suggesting because there are a lot, and you'll need to fix up the table column widths anyway.
Co-authored-by: Chris Markiewicz <effigies@gmail.com>
good point, thank you, done! |
lgtm |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
no comments
This PR is intended to increase the consistency between MEG, EEG, and iEEG for the
*CoordinateSystem
and*CoordinateSystemDescription
fields.The effort is intended as a preparation for stronger validation of these fields (see https://github.com/bids-standard/bids-validator/issues/945).
All of the changes are intended to be clarifications, no modifications or enhancements.
For MEG, I took a relatively hidden paragraph on simultaneous EEG acquisition and turned it into its own section.
@bids-standard/raw-electrophys