Skip to content
This repository has been archived by the owner on Oct 14, 2023. It is now read-only.

cdzombak/pi-am2301a-influx-logger

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

11 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

pi-am2301a-influx-logger

Logs temperature and humidity readings, on a regular basis, to InfluxDB from an AM2301/DHT21 sensor attached to a Raspberry Pi.

Compiling

The DHT library uses C under the hood, so cross-compiling as with normal Go code doesn't work, and I haven't bothered to figure out how to fix it.

So: clone the repository to the Pi Zero W, and run go build . from the root of the repo. Building takes a while.

After compiling, I move the binary to /usr/local/bin and change its owner to root:

sudo chown root:root ./pi-am2301a-influx-logger
sudo mv ./pi-am2301a-influx-logger /usr/local/bin

Connecting the Sensor

The AM2301a/DHT21 use a custom "one wire" interface. Connect the signal wire to a GPIO pin of the Pi. (I used GPIO 4, which is pin 16 on the Pi's GPIO header.)

Aside from that, connect the sensor's power and ground wires to the 5V supply (pin 2 or 4 of the GPIO header) and ground (pin 6 of the GPIO header).

Usage

  • -gpio-pin int: GPIO pin the sensor is connected to. (default 4)
  • -humid-max int: Maximum relative humidity reading. Readings outside this range are discarded. (default 100)
  • -humid-min int: Minimum relative humidity reading. Readings outside this range are discarded. (default 0)
  • -influx-attempts uint: Number of attempts to make to send a reading to InfluxDB. (default 3)
  • -influx-bucket string: InfluxDB bucket. Supply a string in the form database/retention-policy. For the default retention policy, pass just a database name (without the slash character). Required.
  • -influx-password string: InfluxDB password.
  • -influx-server string: InfluxDB server, including protocol and port, eg. http://192.168.1.1:8086. Required.
  • -influx-timeout int: InfluxDB request timeout, in seconds. (default 3)
  • -influx-username string: InfluxDB username.
  • -log-interval int: Logging interval, in seconds (log every X seconds). (default 60)
  • -log-readings: Log temperature/humidity readings to standard error.
  • -max-retries int: Maximum number of attempts to read the DHT21/AM2301 sensor. (default 12)
  • -measurement-name string: InfluxDB measurement name. (default temperature_humidity)
  • -sensor-name string: Value for the sensor_name tag in InfluxDB. Required.
  • -temp-max int: Maximum temperature reading, in degrees C. Readings outside this range are discarded. (default 80)
  • -temp-min int: Minimum temperature reading, in degrees C. Readings outside this range are discarded. (default -40)

Persistent Installation with systemd

Copy logger.service to the /etc/systemd/system directory, and customize it as desired (adjusting the path to the logger binary, options passed to the program, and service name/description). Rename it to something else if you'd like.

Then:

sudo systemctl daemon-reload
sudo systemctl enable logger.service
sudo systemctl start logger.service

Verify the logger is running properly via sudo journalctl -f -u logger.service.

License