6 changes: 3 additions & 3 deletions content/docs/csidriver/_index.md
Original file line number Diff line number Diff line change
Expand Up @@ -41,7 +41,7 @@ The CSI Drivers by Dell implement an interface between [CSI](https://kubernetes-
| Create VolumeSnapshot | yes | yes | yes | yes | yes |
| Create Volume from Snapshot | yes | yes | yes | yes | yes |
| Delete Snapshot | yes | yes | yes | yes | yes |
| [Access Mode](https://kubernetes.io/docs/concepts/storage/persistent-volumes/#access-modes)| **FC/iSCSI:** <br>RWO/<br>RWOP<br> **Raw block:** <br>RWO/<br>RWX/<br>ROX/<br>RWOP | RWO/ROX/RWOP<br><br>RWX (Raw block & NFS only) | RWO/ROX/RWOP<br><br>RWX (Raw block & NFS only) | RWO/RWX/ROX/<br>RWOP | RWO/RWOP<br>(FC/iSCSI)<br>RWO/<br>RWX/<br>ROX/<br>RWOP<br>(RawBlock, NFS) |
| [Access Mode](https://kubernetes.io/docs/concepts/storage/persistent-volumes/#access-modes)| **FC/iSCSI:** <br>RWO/<br>RWOP<br> **Raw block/NFS:** <br>RWO/<br>RWX/<br>ROX/<br>RWOP | RWO/ROX/RWOP<br><br>RWX (Raw block & NFS only) | RWO/ROX/RWOP<br><br>RWX (Raw block & NFS only) | RWO/RWX/ROX/<br>RWOP | RWO/RWOP<br>(FC/iSCSI)<br>RWO/<br>RWX/<br>ROX/<br>RWOP<br>(RawBlock, NFS) |
| CSI Volume Cloning | yes | yes | yes | yes | yes |
| CSI Raw Block Volume | yes | yes | yes | no | yes |
| CSI Ephemeral Volume | no | yes | yes | yes | yes |
Expand All @@ -64,9 +64,9 @@ The CSI Drivers by Dell implement an interface between [CSI](https://kubernetes-
| iSCSI | yes | N/A | yes | N/A | yes |
| NVMeTCP | N/A | N/A | N/A | N/A | yes |
| NVMeFC | N/A | N/A | N/A | N/A | yes |
| NFS | N/A | N/A | yes | yes | yes |
| NFS | yes | N/A | yes | yes | yes |
| Other | N/A | ScaleIO protocol | N/A | N/A | N/A |
| Supported FS | ext4 / xfs | ext4 / xfs / NFS | ext4 / xfs / NFS | NFS | ext3 / ext4 / xfs / NFS |
| Supported FS | ext4 / xfs / NFS | ext4 / xfs / NFS | ext4 / xfs / NFS | NFS | ext3 / ext4 / xfs / NFS |
| Thin / Thick provisioning | Thin | Thin | Thin/Thick | N/A | Thin |
| Platform-specific configurable settings | Service Level selection<br>iSCSI CHAP | - | Host IO Limit<br>Tiering Policy<br>NFS Host IO size<br>Snapshot Retention duration | Access Zone<br>NFS version (3 or 4);Configurable Export IPs | iSCSI CHAP |
| Auto RDM(vSphere) | Yes(over FC) | N/A | N/A | N/A | N/A |
Expand Down
8 changes: 8 additions & 0 deletions content/docs/csidriver/installation/helm/powermax.md
Original file line number Diff line number Diff line change
Expand Up @@ -31,6 +31,7 @@ The following requirements must be met before installing CSI Driver for Dell Pow
- Install Helm 3
- Fibre Channel requirements
- iSCSI requirements
- NFS requirements
- Auto RDM for vSphere over FC requirements
- Certificate validation for Unisphere REST API calls
- Mount propagation is enabled on container runtime that is being used
Expand Down Expand Up @@ -90,6 +91,13 @@ Set up the iSCSI initiators as follows:

For more information about configuring iSCSI, see [Dell Host Connectivity guide](https://www.delltechnologies.com/asset/zh-tw/products/storage/technical-support/docu5128.pdf).

### NFS requirements

CSI Driver for Dell PowerMax supports NFS communication. Ensure that the following requirements are met before you install CSI Driver:
- Configure the NFS network. Please refer [here](https://dl.dell.com/content/manual57826791-dell-powermax-file-protocol-guide.pdf?language=en-us&ps=true) for more details.
- PowerMax Embedded Management guest to access Unisphere for PowerMax.
- Create the NAS server. Please refer [here](https://dl.dell.com/content/manual55638050-dell-powermax-file-quick-start-guide.pdf?language=en-us&ps=true) for more details.

### Auto RDM for vSphere over FC requirements

The CSI Driver for Dell PowerMax supports auto RDM for vSphere over FC. These requirements are applicable for the clusters deployed on ESX/ESXi using virtualized environement.
Expand Down
3 changes: 3 additions & 0 deletions content/docs/csidriver/release/powermax.md
Original file line number Diff line number Diff line change
Expand Up @@ -9,13 +9,16 @@ description: Release notes for PowerMax CSI driver

> Note: Starting from CSI v2.4.0, Only Unisphere 10.0 REST endpoints are supported. It is mandatory that Unisphere should be updated to 10.0. Please find the instructions [here.](https://dl.dell.com/content/manual34878027-dell-unisphere-for-powermax-10-0-0-installation-guide.pdf?language=en-us&ps=true)

>Note: File Replication for PowerMax is currently not supported

### New Features/Changes
- [Added support for OpenShift 4.13](https://github.com/dell/csm/issues/724)
- [Added Storage Capacity Tracking feature for Powermax](https://github.com/dell/csm/issues/876)
- [Make standalone helm chart available from helm repository](https://github.com/dell/csm/issues/877)
- [Added support for Google Anthos 1.15](https://github.com/dell/csm/issues/937)
- [Added support for Volume Limits feature](https://github.com/dell/csm/issues/878)
- [Added support for Kubernetes 1.28](https://github.com/dell/csm/issues/947)
- [Added support for File volumes](https://github.com/dell/csm/issues/861)
### Fixed Issues
There are no fixed issues in this release.

Expand Down
4 changes: 2 additions & 2 deletions content/docs/csidriver/upgradation/drivers/powermax.md
Original file line number Diff line number Diff line change
Expand Up @@ -16,10 +16,10 @@ You can upgrade CSI Driver for Dell PowerMax using Helm or Dell CSI Operator.
1. Upgrade the Unisphere to have 10.0 endpoint support.Please find the instructions [here.](https://dl.dell.com/content/manual34878027-dell-unisphere-for-powermax-10-0-0-installation-guide.pdf?language=en-us&ps=true)
2. Update the `my-powermax-settings.yaml` to have endpoint with 10.0 support.

## Update Driver from v2.6 to v2.7 using Helm
## Update Driver from v2.7 to v2.8 using Helm

**Steps**
1. Run `git clone -b v2.7.0 https://github.com/dell/csi-powermax.git` to clone the git repository and get the driver.
1. Run `git clone -b v2.8.0 https://github.com/dell/csi-powermax.git` to clone the git repository and get the driver.
2. Update the values file as needed.
3. Run the `csi-install` script with the option _\-\-upgrade_ by running:
```bash
Expand Down
8 changes: 8 additions & 0 deletions content/docs/deployment/csmoperator/drivers/powermax.md
Original file line number Diff line number Diff line change
Expand Up @@ -14,6 +14,7 @@ Note that the deployment of the driver using the operator does not use any Helm
The CSI Driver for Dell PowerMax can create PVC with different storage protocols access :
* direct Fiber Channel
* direct iSCSI
* NFS
* Fiber Channel via VMware Raw Device Mapping
In most cases, you will use one protocol only; therefore you should comply with the according prerequisites and not the others.

Expand Down Expand Up @@ -80,6 +81,13 @@ If the `iscsid.service` is not running, then perform the following steps on each
3. Ensure that iscsid service is running - Enable ```sudo systemctl enable iscsid``` & restart ```sudo systemctl restart iscsid``` iscsid if necessary.
Note: If your worker nodes are running Red Hat CoreOS, make sure that automatic ISCSI login at boot is configured. Please contact RedHat for more details.

### NFS requirements

CSI Driver for Dell PowerMax supports NFS communication. Ensure that the following requirements are met before you install CSI Driver:
- Configure the NFS network. Please refer [here](https://dl.dell.com/content/manual57826791-dell-powermax-file-protocol-guide.pdf?language=en-us&ps=true) for more details.
- PowerMax Embedded Management guest to access Unisphere for PowerMax.
- Create the NAS server. Please refer [here](https://dl.dell.com/content/manual55638050-dell-powermax-file-quick-start-guide.pdf?language=en-us&ps=true) for more details.

### Linux multipathing requirements

CSI Driver for Dell PowerMax supports Linux multipathing. Configure Linux multipathing before installing the CSI Driver.
Expand Down
2 changes: 2 additions & 0 deletions content/docs/replication/_index.md
Original file line number Diff line number Diff line change
Expand Up @@ -53,6 +53,8 @@ CSM for Replication provides the following capabilities:
| Storage Array | PowerMax 2500/8500 PowerMaxOS 10 (6079) , PowerMaxOS 10.0.1 (6079) <br> PowerMax 2000/8000 - 5978.711.xxx, 5978.479.xxx <br> Unisphere 10.0,10.0.1 | 1.0.x, <br> 2.0.x, 2.1.x, <br> 3.0, 3.2, 3.5 | OneFS 8.1, 8.2, 9.0, 9.1, 9.2, 9.3, 9.4, 9.5 | 3.6.x, 4.0|
{{</table>}}

>Note: File Replication for PowerMax is currently not supported

## Details

As on the storage arrays, all replication related Kubernetes entities are required/created in pairs -
Expand Down
2 changes: 2 additions & 0 deletions content/docs/replication/deployment/powermax.md
Original file line number Diff line number Diff line change
Expand Up @@ -10,6 +10,8 @@ Container Storage Modules (CSM) Replication sidecar is a helper container that i

CSI driver for Dell PowerMax supports necessary extension calls from `dell-csi-extensions`. To be able to provision replicated volumes you would need to do the steps described in the following sections.

>Note: File Replication for PowerMax is currently not supported

### Before Installation

#### On Storage Array
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -8,7 +8,7 @@ description: >

User can migrate existing pre-provisioned volumes to another storage array by using the array migration feature.

> _**NOTE**_: Currently only migration of standalone volumes is supported.
> _**NOTE**_: Currently only migration of standalone block volumes is supported.

## Prerequisites

Expand Down
2 changes: 2 additions & 0 deletions content/docs/replication/release/_index.md
Original file line number Diff line number Diff line change
Expand Up @@ -17,6 +17,8 @@ Description: >
| --------------------------------------------- | ------------------------------------------------------------------ |
| [782](https://github.com/dell/csm/issues/782) | **PowerScale:** Target NFS exports are not deleted even though target directories are deleted |

>Note: File Replication for PowerMax is currently not supported

### Known Issues

| Github ID | Description |
Expand Down