STEPS 1:

  1. Pin Tx = Low (70 ms)
  2. Pin Tx = High (120 ms)
  3. Set Baudrate = 10400 bps
  4. Wake Up with send to ECU code = FE 04 72 8C
  5. ECU Response with code = 0E 04 72 7C
  6. Send Initialise code = 72 05 00 F0 99
  7. ECU Response = 02 04 00 FA
  8. Repeat point 1 if there is no response from the ECU. And continue the next Steps if there is a response from the ECU

STEPS 2:

  1. Send Request ECM ID = 72 05 71 00 18
  2. ECU Response (eg) = 02 0F 71 00 01 02 32 0F 01 00 00 00 00 00 39
  3. Send Request data table 11 = 72 05 71 11 07
  4. ECU Response data table 11 (eg) = 02 19 71 11 00 00 00 00 FF 0A AA 0A FF B2 FF FF 79 00 00 00 80 53 09 F1 5C
  5. If the ecu response data in table 11 is = 02 05 71 11 77
  6. then continue to request data table 17. Send to ECU = 72 05 71 17 01
  7. ECU will respond to data table 17 (eg) = 02 18 71 17 00 00 00 00 FF 0A FF FF FF FF 79 00 00 80 8D 00 00 00 00 D3

All processes are carried out for a maximum of 2 seconds otherwise the ECU will sleep again. For that, do step 1 and step 2 sequentially

DESCRIPTION:

  • Request = 72 AA BB CC CS
  • 72 = Request Header Code
  • AA = Number of Bytes (including the Checksum)
  • BB = Query Table
  • CC = Table
  • CS = Checksum

CHECKSUM

  • Usually to make a data table can be started from 00 to FF. With code 72 05 71 ZZ CS
  • Where ZZ = data table 00 to FF and CS = Checksum
  • The formula checksum = 100 - (sumbyte and FF)
  • For example the data request Table 13 = 72 05 71 13 CS Then the checksum value = 100 - ((72 + 05 + 71 + 13) AND FF) , result CS = 05
  • So the data request table 13 = 72 05 71 13 05