Skip to content
This repository has been archived by the owner on Oct 4, 2021. It is now read-only.

RC35 Temperatures show ? #100

Closed
sysrun opened this issue Apr 17, 2019 · 2 comments
Closed

RC35 Temperatures show ? #100

sysrun opened this issue Apr 17, 2019 · 2 comments
Labels
bug Something isn't working

Comments

@sysrun
Copy link

sysrun commented Apr 17, 2019

I already read the other issues.

Just installed the current dev branch - Temperatures show ?

Switched to manual mode and send "thermostat read 3E"

Reply was:
Thermostat -> me, type 0x3E telegram: 10 0B 3E 00 80 02 2E 7D 00 00 00 00 00 00 00 00 64 11 2C 00 (CRC=58), #data=16

Setpoint Temp for HK1 is 0x2E = so 46/2 = 23 Degree - so the received telegram is correct.

But "info" shows "Setpoint room temperature: ? C" - and its not changing after toggling the modes and waiting several minutes.

Update: The values are send out to MQTT corrently... weird

@sysrun sysrun added the bug Something isn't working label Apr 17, 2019
proddy added a commit that referenced this issue Apr 17, 2019
@proddy
Copy link
Collaborator

proddy commented Apr 17, 2019

fixed in dev. If either the setpoint or current room temps were 0 or unavailable then both would show a "?". Now in your case it would display the setpoint temp correctly but the current temp would be empty. not sure if this is the desired result?

@sysrun
Copy link
Author

sysrun commented Apr 18, 2019

The "current temp" is stated as "7D 00" in my case - so no sensor value, which is correct

Just updated to newest dev - works as expected now :)

Setpoint room temperature: 23.0 C
Current room temperature: ? C

Sign up for free to subscribe to this conversation on GitHub. Already have an account? Sign in.
Labels
bug Something isn't working
Projects
None yet
Development

No branches or pull requests

2 participants