Merge pull request #4 from h-schwanbeck/input/modbus
Browse files Browse the repository at this point in the history
Input/modbus - Improvement of default configuration
  • Loading branch information
garciaolais authored Sep 27, 2019
2 parents cfeec73 + fceaa69 commit 048553d
Show file tree
Hide file tree
Showing 2 changed files with 84 additions and 56 deletions.
58 changes: 36 additions & 22 deletions plugins/inputs/modbus/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -5,34 +5,48 @@ The Modbus plugin collects Discrete Inputs, Coils, Input Registers and Holding R
### Configuration:

```toml
## Connection Configuration
##
## The module supports connections to PLCs via MODBUS/TCP or
## via serial line communication in binary (RTU) or readable (ASCII) encoding
##

## Slave ID - addresses a MODBUS device on the bus
## Range: 0 - 255 [0 = broadcast; 248 - 255 = reserved]
slave_id = 1
time_out = "1s"
#protocol = "RTU"

#TCP
controller = "tcp://localhost:1502"
## Timeout for each request
timeout = "1s"

# TCP - connect via Modbus/TCP
controller = "tcp://localhost:502"

#RTU
# Serial (RS485; RS232)
#controller = "file:///dev/ttyUSB0"
#baud_rate = 9600
#data_bits = 8
#parity = "N"
#stop_bits = 1
#transmission_mode = "RTU"


## Measurements
##

## Digital Variables, Discrete Inputs and Coils
## name - the variable name
## address - variable address

discrete_inputs = [
{ name = "Start", address = [0]},
{ name = "Stop", address = [1]},
{ name = "Reset", address = [2]},
{ name = "EmergencyStop", address = [3]},
{ name = "Stop", address = [1]},
{ name = "Reset", address = [2]},
{ name = "EmergencyStop", address = [3]},
]
coils = [
{ name = "Motor1-Run", address = [0]},
{ name = "Motor1-Jog", address = [1]},
{ name = "Motor1-Stop", address = [2]},
{ name = "Motor1-Run", address = [0]},
{ name = "Motor1-Jog", address = [1]},
{ name = "Motor1-Stop", address = [2]},
]

## Analog Variables, Input Registers and Holding Registers
Expand All @@ -43,21 +57,21 @@ The Modbus plugin collects Discrete Inputs, Coils, Input Registers and Holding R
## |---BADC - Mid-Big Endian
## |---CDAB - Mid-Little Endian
## data_type - UINT16, INT16, INT32, UINT32, FLOAT32, FLOAT32-IEEE (the IEEE 754 binary representation)
## scale - the final numeric variable representation
## scale - the final numeric variable representation
## address - variable address

holding_registers = [
{ name = "PowerFactor", byte_order = "AB", data_type = "FLOAT32", scale="0.01" , address = [8]},
{ name = "Voltage", byte_order = "AB", data_type = "FLOAT32", scale="0.1" , address = [0]},
{ name = "Energy", byte_order = "ABCD", data_type = "FLOAT32", scale="0.001" , address = [5,6]},
{ name = "Current", byte_order = "ABCD", data_type = "FLOAT32", scale="0.001" , address = [1, 2]},
{ name = "Frequency", byte_order = "AB", data_type = "FLOAT32", scale="0.1" , address = [7]},
{ name = "Power", byte_order = "ABCD", data_type = "FLOAT32", scale="0.1" , address = [3,4]},
]
{ name = "PowerFactor", byte_order = "AB", data_type = "FLOAT32", scale="0.01", address = [8]},
{ name = "Voltage", byte_order = "AB", data_type = "FLOAT32", scale="0.1", address = [0]},
{ name = "Energy", byte_order = "ABCD", data_type = "FLOAT32", scale="0.001", address = [5,6]},
{ name = "Current", byte_order = "ABCD", data_type = "FLOAT32", scale="0.001", address = [1, 2]},
{ name = "Frequency", byte_order = "AB", data_type = "FLOAT32", scale="0.1", address = [7]},
{ name = "Power", byte_order = "ABCD", data_type = "FLOAT32", scale="0.1", address = [3,4]},
]
input_registers = [
{ name = "TankLevel", byte_order = "AB", data_type = "INT16", scale="1" , address = [0]},
{ name = "TankPH", byte_order = "AB", data_type = "INT16", scale="1" , address = [1]},
{ name = "Pump1-Speed", byte_order = "ABCD", data_type = "INT32", scale="1" , address = [3,4]},
{ name = "TankLevel", byte_order = "AB", data_type = "INT16", scale="1", address = [0]},
{ name = "TankPH", byte_order = "AB", data_type = "INT16", scale="1", address = [1]},
{ name = "Pump1-Speed", byte_order = "ABCD", data_type = "INT32", scale="1", address = [3,4]},
]
```
### Example Output:
Expand Down
82 changes: 48 additions & 34 deletions plugins/inputs/modbus/modbus.go
Original file line number Diff line number Diff line change
Expand Up @@ -19,13 +19,13 @@ import (

type Modbus struct {
Controller string `toml:"controller"`
Protocol string `toml:"protocol"`
Transmission_Mode string `toml:"transmission_mode"`
Baud_Rate int `toml:"baud_rate"`
Data_Bits int `toml:"data_bits"`
Parity string `toml:"parity"`
Stop_Bits int `toml:"stop_bits"`
Slave_Id int `toml:"slave_id"`
Time_out internal.Duration `toml:"time_out"`
Timeout internal.Duration `toml:"timeout"`
Discrete_Inputs []tag `toml:"discrete_inputs"`
Coils []tag `toml:"coils"`
Holding_Registers []tag `toml:"holding_registers"`
Expand Down Expand Up @@ -68,59 +68,73 @@ const (
)

var ModbusConfig = `
## Connection Configuration
##
## The module supports connections to PLCs via MODBUS/TCP or
## via serial line communication in binary (RTU) or readable (ASCII) encoding
##
## Slave ID - addresses a MODBUS device on the bus
## Range: 0 - 255 [0 = broadcast; 248 - 255 = reserved]
slave_id = 1
time_out = "1s"
#protocol = "RTU"
#TCP
controller = "tcp://localhost:1502"
## Timeout for each request
timeout = "1s"
# TCP - connect via Modbus/TCP
controller = "tcp://localhost:502"
#RTU
# Serial (RS485; RS232)
#controller = "file:///dev/ttyUSB0"
#baud_rate = 9600
#data_bits = 8
#parity = "N"
#stop_bits = 1
#transmission_mode = "RTU"
## Measurements
##
## Digital Variables, Discrete Inputs and Coils
## name - the variable name
## address - variable address
discrete_inputs = [
{ name = "Start", address = [0]},
{ name = "Stop", address = [1]},
{ name = "Reset", address = [2]},
{ name = "EmergencyStop", address = [3]},
{ name = "Start", address = [0]},
{ name = "Stop", address = [1]},
{ name = "Reset", address = [2]},
{ name = "EmergencyStop", address = [3]},
]
coils = [
{ name = "Motor1-Run", address = [0]},
{ name = "Motor1-Jog", address = [1]},
{ name = "Motor1-Stop", address = [2]},
]
{ name = "Motor1-Run", address = [0]},
{ name = "Motor1-Jog", address = [1]},
{ name = "Motor1-Stop", address = [2]},
]
## Analog Variables, Input Registers and Holding Registers
## name - the variable name
## byte_order - the ordering of bytes
## name - the variable name
## byte_order - the ordering of bytes
## |---AB, ABCD - Big Endian
## |---BA, DCBA - Little Endian
## |---BADC - Mid-Big Endian
## |---CDAB - Mid-Little Endian
## data_type - UINT16, INT16, INT32, UINT32, FLOAT32, FLOAT32-IEEE (the IEEE 754 binary representation)
## scale - the final numeric variable representation
## scale - the final numeric variable representation
## address - variable address
holding_registers = [
{ name = "PowerFactor", byte_order = "AB", data_type = "FLOAT32", scale="0.01" , address = [8]},
{ name = "Voltage", byte_order = "AB", data_type = "FLOAT32", scale="0.1" , address = [0]},
{ name = "Energy", byte_order = "ABCD", data_type = "FLOAT32", scale="0.001" , address = [5,6]},
{ name = "Current", byte_order = "ABCD", data_type = "FLOAT32", scale="0.001" , address = [1, 2]},
{ name = "Frequency", byte_order = "AB", data_type = "FLOAT32", scale="0.1" , address = [7]},
{ name = "Power", byte_order = "ABCD", data_type = "FLOAT32", scale="0.1" , address = [3,4]},
]
{ name = "PowerFactor", byte_order = "AB", data_type = "FLOAT32", scale="0.01", address = [8]},
{ name = "Voltage", byte_order = "AB", data_type = "FLOAT32", scale="0.1", address = [0]},
{ name = "Energy", byte_order = "ABCD", data_type = "FLOAT32", scale="0.001", address = [5,6]},
{ name = "Current", byte_order = "ABCD", data_type = "FLOAT32", scale="0.001", address = [1, 2]},
{ name = "Frequency", byte_order = "AB", data_type = "FLOAT32", scale="0.1", address = [7]},
{ name = "Power", byte_order = "ABCD", data_type = "FLOAT32", scale="0.1", address = [3,4]},
]
input_registers = [
{ name = "TankLevel", byte_order = "AB", data_type = "INT16", scale="1" , address = [0]},
{ name = "TankPH", byte_order = "AB", data_type = "INT16", scale="1" , address = [1]},
{ name = "Pump1-Speed", byte_order = "ABCD", data_type = "INT32", scale="1" , address = [3,4]},
{ name = "TankLevel", byte_order = "AB", data_type = "INT16", scale="1", address = [0]},
{ name = "TankPH", byte_order = "AB", data_type = "INT16", scale="1", address = [1]},
{ name = "Pump1-Speed", byte_order = "ABCD", data_type = "INT32", scale="1", address = [3,4]},
]
`

Expand All @@ -145,7 +159,7 @@ func connect(m *Modbus) error {
return _err
}
m.tcp_handler = mb.NewTCPClientHandler(host + ":" + port)
m.tcp_handler.Timeout = m.Time_out.Duration
m.tcp_handler.Timeout = m.Timeout.Duration
m.tcp_handler.SlaveId = byte(m.Slave_Id)
m.client = mb.NewClient(m.tcp_handler)
err := m.tcp_handler.Connect()
Expand All @@ -155,9 +169,9 @@ func connect(m *Modbus) error {
m.is_connected = true
return nil
case "file":
if m.Protocol == "RTU" {
if m.Transmission_Mode == "RTU" {
m.serial_handler = mb.NewRTUClientHandler(u.Path)
m.serial_handler.Timeout = m.Time_out.Duration
m.serial_handler.Timeout = m.Timeout.Duration
m.serial_handler.SlaveId = byte(m.Slave_Id)
m.serial_handler.BaudRate = m.Baud_Rate
m.serial_handler.DataBits = m.Data_Bits
Expand All @@ -170,9 +184,9 @@ func connect(m *Modbus) error {
}
m.is_connected = true
return nil
} else if m.Protocol == "ASCII" {
} else if m.Transmission_Mode == "ASCII" {
m.ascii_handler = mb.NewASCIIClientHandler(u.Path)
m.ascii_handler.Timeout = m.Time_out.Duration
m.ascii_handler.Timeout = m.Timeout.Duration
m.ascii_handler.SlaveId = byte(m.Slave_Id)
m.ascii_handler.BaudRate = m.Baud_Rate
m.ascii_handler.DataBits = m.Data_Bits
Expand All @@ -186,7 +200,7 @@ func connect(m *Modbus) error {
m.is_connected = true
return nil
} else {
return errors.New(fmt.Sprintf("Not valid protcol [%s] - [%s] ", u.Scheme, m.Protocol))
return errors.New(fmt.Sprintf("Not valid protcol [%s] - [%s] ", u.Scheme, m.Transmission_Mode))
}
default:
return errors.New("Not valid Controller")
Expand Down

0 comments on commit 048553d

Please sign in to comment.