This repository has been archived by the owner on May 8, 2021. It is now read-only.
-
Notifications
You must be signed in to change notification settings - Fork 1
/
ChangeLog
769 lines (534 loc) · 29.1 KB
/
ChangeLog
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
*****************************************
*** DOS/32A DOS Extender -- ChangeLog ***
*****************************************
[2006-04-20]
DOS/32 Advanced DOS Extender, version 9.1.2
===========================================
DOS Extender (DOS32A.EXE):
--------------------------
+ Bugfix: Int 21h function 3Fh refused to return when reading from STDIN
(reported by Gianni Gallucci)
+ Bugfix: in irq_fail fn, hardware exception #9 doesn't have exception code
(reported by Charles Hyde)
+ applied mode.asm patch (also by Charles Hyde from Infineon) with minor
formatting changes; I'm rather ambivalent about implementing the others
into the mainstream builds (in particular the PAE one), will make those
available from the development (beta) page...
[2005-12-12]
DOS/32 Advanced DOS Extender, version 9.1.1
===========================================
DOS Extender (DOS32A.EXE):
--------------------------
+ improved memory allocation under Clean system: INT 15h, AX=0E801h is used
if AX=0E820h fails (based on patch provided by Arthur Kalliokoski)
[2005-11-08]
DOS/32 Advanced DOS Extender, version 9.1.0
===========================================
DOS Extender (DOS32A.EXE):
--------------------------
+ added support for SSE/SSE2/SSE3 capable processors
+ added preliminary support for PE file format (recognized but not yet implemented)
+ with verbose mode turned on the DOS Extender will pause prompting to press a key;
this gives a chance to read loader info before the app kicks in
+ internal debugger has been dropped, CLIENT/debug.asm has been heavily rewritten
+ INT 1 and INT 3 op-codes are now treated by DOS/32A as no-ops, this works around
some lame anti-debugging protections (Null-pointer protection works as expected)
+ "VCPI/DPMI Detection Order" option has been removed, DOS/32A unconditionally
favours VCPI over DPMI, if and when possible
+ "Internal Exception Control" option has been removed, DOS/32A is always in control
of the exception handling
+ "Trap and Report Emulated IRQs" option has been removed, this simplifies IRQ
handling
+ "Extended Memory Blocks Checking" option has been removed, DOS/32A unconditionally
checks EMB integrity
+ DPMITST environment option is no longer supported; it is still recognized but is
now a no-op
+ whenever possible, DOS/32A will favour INT 15h/XMS systems over VCPI/DPMI,
(thanks wd)
+ INT 31h DPMI last function entry is cached so that subsequent calls with the same
function number do no search the lookup table
+ INT 31h DPMI functions 0E00h & 0E01h no longer virtualize FPU EM & MP flags
+ additional PIC constraint: slave PIC may not be mapped onto INT 8
+ slightly reduced run-time complexity of the IRQ handling code
+ exception handlers are now invoked with the correct stack frame (as mandated
by DPMI v0.9 spec)
+ all the exception vectors are now hooked under external DPMI (symmetric with
built-in DPMI and using the same exception handlers)
SUNSYS Setup Utility (SS.EXE):
------------------------------
+ the following options in the Kernel menu have been deprecated:
"VCPI/DPMI Detection Order"
"Internal Exception Control"
"Trap and Report Emulated IRQs"
"Extended Memory Blocks Checking"
it is still possible to toggle the state of these options, but the changes have
no effect on the DOS Extender
SUNSYS Debugger (SD.EXE):
-------------------------
+ R.I.P.
[2005-05-19]
DOS/32 Advanced DOS Extender, version 7.35
==========================================
DOS Extender (DOS32A.EXE):
--------------------------
+ mouse callback code cleanup
+ allocation of up to 2Gig under Clean system (Int 15h, AX=E820h)
+ with verbose mode active and not under external DPMI the entry point
of application will trap to internal debugger
[2005-01-12]
DOS/32 Advanced DOS Extender version 7.33
=========================================
DOS Extender (DOS32A.EXE):
--------------------------
+ Bugfix: exec loader could crash the DOS Extender during startup in rare situations
+ Bugfix: DPMI function 0301h can not transfer data on stack to real mode procedure
+ Int 21h functions 4402h, 4403h, 4404h, 4405h, (DOS IOCTL) have been extended
+ Int 21h functions 3Fh & 40h (DOS IO) have been rewritten
+ mouse callback can now handle non-standard stack frames
SUNSYS Bind Utility (SB.EXE):
-----------------------------
+ Bugfix: minor binding problems with unbound LE/LX execs
+ removed check for DOS32A environment string
SUNSYS Compress Utility (SC.EXE):
---------------------------------
+ removed check for DOS32A environment string
SUNSYS Setup Utility (SS.EXE):
------------------------------
+ removed Lock and Version checks
*******************************************************************************
Release 8
DOS/32 Advanced DOS Extender version 7.1
========================================
News:
-----
+ This release of DOS/32A is distributed under a new license. See "license.txt"
for more information.
+ The complete source code of the DOS Extender and its tools is included with
this release.
DOS Extender:
-------------
+ Fixed bug in DPMI function 0503h when in certain cases the contents of the
memory block being reallocated was not copied to the new location.
+ Minor fix: DOS/32A environment configuration option /NOWARN can now accept
several warnings separated by a comma (eg /NOWARN:9003,9004).
Other:
------
+ Minor updates to the documentation manuals, mainly to reflect the new
licensing issues.
*******************************************************************************
Service Pack 1 (Revision [C])
DOS/32 Advanced DOS Extender version 7.0
========================================
News:
-----
+ SVER Utility program. This utility can be used to find out the version
of DOS/32A, STUB/32A or STUB/32C and to display the OEM Information
appended to the LC-style executables by Original Equipment Vendors.
DOS Extender:
-------------
+ Fixed problem in DOS/32A DPMI kernel causing the DOS Extender not being
able to properly callback the IRQs of the second PIC to the protected mode
handlers.
SUNSYS Setup Utility:
---------------------
+ Fixed minor problem when in Kernel Config window setting VCPI PhysTables
to 0 and switching to Hex mode caused the number to flash red incorrectly
indicating an errorneously enered value.
*******************************************************************************
Release 7
DOS/32 Advanced DOS Extender version 7.0
========================================
News
----
+ A new high performance D32A C/C++ Run-Time Library is now included with
DOS/32 Advanced DOS Extender. The Library is located in .\L32 directory
and its C/C++ header in .\H32 directory.
+ The documentation manuals supplied with DOS/32 Advanced DOS Extender are
now in the HTML format. The plain-text based manuals have been dropped. To
view the new HTML based manuals use an internet browser (Netscape Navigator
is highly recommended although Explorer will also do fine), select "File ->
Open File" from the browser's menu and open "manual.htm" file located in the
.\DOCS directory.
DOS Extender
------------
+ Year 2000 compliance has been added for DOS/32 Advanced DOS Extender and
all of the utilities accompanying it.
+ When running under _external_ DPMI host, DOS/32A will remove its own DPMI
Kernel from memory, thus freeing up up to 10KB of conventional DOS memory.
+ Added exception handling under _external_ DPMI, DOS/32A will trap exceptions
#0, #6, #13 and #14 (ie the most common) and report the complete machine
state; DOS/32A will now also report where the exception came from by
specifying "KERNEL" for ADPMI Kernel, "CLIENT" for DOS/32A Client, "APP/32"
for the currently running application and "APP/??" if exception's origin is
unknown.
+ Added support for "Performance Counters" which monitor the number of mode
switches for INTs, IRQs, and Callbacks; a new Extended DPMI API function
(AX=0A00h, then AL=09h) provides access to these.
+ Added support for protected mode TSRs installed with INT 21h, AH=31h
function; contents of DX register passed to this function are ignored
when called from protected mode.
+ Added new warning (9006): "incompatible version of DOS/32A already running"
issued when the parent and the child applications are running under
different versions of DOS/32A (when spawn() programs).
+ Added new environment option "/NOWARN:xxxx" to disable particular warnings,
ie /NOWARN:9003.
+ Added new environment option "/NOC" to disable explictly the copyright
banner. The warnings are still displayed on the screen.
+ Increased the maximum of loadable Objects from 32 to 64 per application.
+ Improved CTRL-C and CTRL-Break handling in the DOS Extender's Client code,
which solves problems with these key combinations not properly detected when
running under some external DPMI hosts (in particular Windows).
+ Improved Interrupt switching algorithm in DOS/32A DPMI Kernel, also improved
algorithm enabling A20 gate when running in Clean system.
+ Improved error checking in Extended DOS functions 0FF95h and 0FF97h: they
will now fail calls that allocate 0 bytes or >1MB.
+ Improved support for VCPI system software; fixed bug in VCPI initialization
code which caused the DOS Extender's kernel to fail to free all the
allocated PageTables on exit in some situations. You are now also allowed to
set VCPI PhysTables value to zero to save some conventional memory if not
using physical memory mapping DPMI functions 0800h and 0801h.
+ Minor fix: DPMI function 0001h (Free Selector) will now fail any calls that
try to free the current CS (Kernel) or SS (App. stack) selectors.
+ Minor fix: Extended DOS function 4Ch (Terminate) will release ZERO selector
before exiting to DOS.
+ Minor improvements in the LC-style file format loader: uncompressed Objects
are loaded slightly faster.
+ Fixed bug in Extended DOS function AH=40h (Write to file) when DOS/32A would
crash when running under external DPMI and writing to disk with no free
space left.
+ Fixed bug in DOS/32 Advanced environment configuration reading functions,
when the DOS Extender would sometimes at startup take off into "hyperspace"
reading the whole environment, instead of just one line (DOS32A=...).
+ Removed check for invalid limits in DPMI function 0008h; DOS/32A will now
unconditionally perform auto-correction of selector's limit if it is out
of range.
+ Removed support for bottom-up allocation scheme when running under Clean
(INT 15h) system software. Instead improved support for top-down allocation
scheme which yields better performance and more extended memory.
+ Reduced the default number of Page Tables reserved for physical memory
mapping from 4 down to 2 (eq 8MB).
+ Reduced the default size of DOS Transfer Buffer from 16KB down to 8KB, does
not affect disk I/O performance but brings the memory requirements down.
SUNSYS Bind Utility:
--------------------
+ Fixed all known problems.
+ Added support for OEM title information for LC-style execs.
+ Otherwise no major changes visible to the user.
SUNSYS Compress Utility:
------------------------
+ Fixed all known problems.
+ Improved (rewritten) "Advanced Preprocessing" algorithm.
+ Added support for OEM title information for LC-style execs.
+ Otherwise no major changes visible to the user.
SUNSYS Setup Utility:
---------------------
+ Removed "Selector Invalid Limit Check" option.
+ Otherwise no major changes visible to the user.
SUNSYS Debugger:
----------------
+ No major changes.
*******************************************************************************
Release 6
DOS/32 Advanced DOS Extender version 6.00
=========================================
News
----
+ New SUNSYS Compress Utility program which allows compression of LE- and
LX-style Linear Executables into the new LC-style Linear Compressed file
format (see "sc.txt" help file located in .\DOCS directory).
+ Configurable stub file STUB/32C which can be configured by SUNSYS Setup
Utility program, located in .\BINW directory and named "stub32c.exe".
DOS Extender
------------
+ Removed fatal error (0008): "configuration header corrupted", which was never
used unless the DOS Extender was linked incorrectly.
+ Upon a crash (exception) in protected mode application the DOS Extender will
report the unrelocated crash address for _any_ Object, not the only one that
had entry point in it as it did before.
+ DOS/32 Advanced now supports allocation of more than 64MB of memory without
using Virtual Memory. The maximum amount of memory the DOS Extender can
allocate is limited to 2GB when running under XMS and to 256MB under VCPI.
+ Fixed problem with Verbose Mode when the DOS Extender would report the
incorrect size of DPMI memory when allocated >64MB. The DPMI memory size is
now reported in KB when below 64MB, and in MB when above.
+ Added support for LC-style Linear Compressed protected mode executables. By
using SUNSYS Compress Utility the users can compress LE and LX applications
into the new LC file format.
+ Added new run-time error (4007): "not enough DOS Transfer Buffer space to
load LC-exec" which is reported when loading Linear Compressed executables
and the size of DOS Transfer Buffer is set below 8KB.
+ The Loader will skip allocation of selectors for subsequently loaded 32bit
Objects, and will make the application happy with only one 32bit CODE and
one 32bit DATA selectors respective. This will prevent wasting of selectors
in applications which contain more than two 32bit Objects.
+ DPMI functions 0602h and 0603h are supported and will return with CF clear
without actually doing anything good.
SUNSYS Bind Utility:
--------------------
+ Added new commands and options "/BC", "/RC", "/BN", "/UN", "/Q", "/S" and
"/H" (or "/?"). Refer to "sb.txt" help file for more information.
SUNSYS Compress Utility:
------------------------
+ This one is new for this release. See "sc.txt" for help.
SUNSYS Setup Utility:
---------------------
+ Added support for configurable stubs, STUB/32C files.
+ Added (actually documented) options "/INFO", "/LOCK", "/UNLOCK", "/QUIET",
"/SILENT" and "/H" (or "/?"). See "ss.txt" help file.
SUNSYS Debugger:
----------------
+ Minor changes, fixed mouse problem with some mouse drivers when the cursor
would disappear when moving it below the bottom of the screen.
*******************************************************************************
Release 5
DOS/32 Advanced DOS Extender version 5.00
=========================================
DOS Extender
------------
+ Resolved problem with WATCOM Linker v11.0(a) when the DOS Extender was not
able to correctly recognize and load the LX-style executables.
+ The DOS Extender now supports, and will correctly load Objects with the size
of zero. However, as such Objects will in most cases indicate an error in
the protected mode application (wlink dead code elimination should kill'em),
the DOS Extender will issue a new warning (9005) to inform the user about
this situation.
+ The default size of the DOS Transfer Buffer is now 16KB instead of 64KB.
This not only reduced the DOS memory requirements, but also improved the
DOS Extender's disk I/O throughoutput.
+ When showing information about Selectors in the exception report listing
the DOS Extender will no longer list the DPL of a Selector as it always
was equal to 0. Instead, DOS/32 Advanced will show a better explanation
of Selector's attributes (CODE/DATA and 16/32 bit).
+ DPMI function 0008h, Set Segment Limit, will now report invalid limits as a
new run-time error (6006), which will result in application termination. You
can always turn off this feature, by using the SUNSYS Setup Utility.
+ Fatal error (3005) will now report message "error in app exec" which means
that the application was corrupted or an error occurred at link time.
+ With VERBOSE mode turned on the DOS Extender will now list the PSP_Sel,
Env_Sel and Env_Seg to provide additional information about PSP Selector,
Environment Selector and Environment real mode Segment allocated by the
DOS Extender for application. In addition, the DOS Extender will report
Process_ID and Module Name in the exception listing which can be useful
when spawning applications.
+ Added new feature: "Start Full-Screen under Windows". DOS/32 Advanced will
switch the application to the full-screen mode when running under Windows in
a DOS-box window. Can be turned off (the default is off).
+ Another new option in the DOS Extender: "Ignore DOS/4G API Extension Calls".
Documented in the "ss.txt" help file. Certain programs which otherwise use
DOS/4G API extensions can now be run under DOS/32 Advanced.
+ The DOS Extender will now automatically deinstall the possibly installed
mouse ISR by issuing INT 33h with AX=000Ch and ES:EDI=0 on exit to DOS.
+ New extended DOS functions 0FF94h..0FF97h are now supported for allocation
of DOS memory. These functions work in exactly the same way as functions
0FF90h..0FF93h. Look into "Programmer's Reference" ("prog_ref.doc" file)
documentation for more information about those.
+ The spawning techniques of DOS/32 Advanced have been greatly improved. The
required size of the "DOS Transfer Buffer" is now 1KB instead of 4KB when
using extended DOS function AH=4Bh to spawn. Read more about this in the
"Technical Reference" ("rech_ref.doc" file) documentation.
+ Memory management ADPMI functions have been rewritten and now offer improved
performance and security. Allocated Extended Memory Blocks are now aligned
on Paragraph (16-byte) boundary and protection against EMB overwriting is
now 99% safe.
+ Once again, DOS/32 Advanced DOS Extender requires no extended memory to load
and execute a protected mode program. The relocations are now loaded into
DOS memory first, only when not enough DOS memory, will they be loaded into
extended memory (a very rare situation).
+ Fixed minor problem in DPMI functions 0800h/0801h when the last mapped page
was not marked as last.
+ Fixed bug in extended DOS function AH=40h, Write to File, when truncation
of files (using ECX = 0) did not work as expected.
+ Corrected DPMI function 050Ah, Get Base and Size of Memory Block. The base
reported now points to the actual address of memory block instead of block
header.
+ Fixed problem with IRQ 7 which was not processed by DOS/32 Advanced built-in
DPMI correctly.
+ Fixed a small problem when the DOS Extender could not load and execute the
"raw" LE/LX programs, ie applications not bound to any stub.
+ The ADPMI function 0EEFFh now returns EAX with "D32A" ID-string instead of
"PMDW". This function has been pretty much standardized and can be used
for effective detection of the currently running DOS Extender.
+ The Free Package version now supports DPMI functions 0800h and 0801h for
mapping of linear memory.
+ Support for Win95 Long File Names has been included into this version of
DOS/32 Advanced. Look for information on these functions (INT 21h, AX=71xxh)
in the "Programmer's Reference" documentation ("prog_ref.doc" file).
SUNSYS Setup Utility:
---------------------
+ Two new options have been added: "Ignore DOS/4G API Extension Calls" in the
"Configure DOS/32A DPMI Kernel" menu, and "Start Full-Screen under Windows"
in the "Configure DOS/32A DOS Extender" menu.
+ Several options have been renamed, and placed in a more proper (logical)
order. You really should not have problems with recognizing them though.
SUNSYS Bind Utility:
--------------------
+ Unbinding of LE/LX executables is now supported in the Free Package version.
SUNSYS Debugger:
----------------
+ Fully functional, except for the "System Interrupt History" which is
supported in the Pro version only. Otherwise no major changes.
*******************************************************************************
Release 4
DOS/32 Advanced DOS Extender version 4.30
=========================================
Install Program:
----------------
+ The Install program will now automatically copy file "dos32a.lnk" into
WATCOM's BINW or BIN directory (depending on which version of WATCOM C/C++
you have) if you select auto-system-update (which is strongly recommended).
+ You can now install DOS/32 Advanced in any directory, not just "DRV:\DIR" as
it was before. You can install it for example in "C:\WATCOM\DOS32A" or
anything like that.
+ File "dos4gw.exe" which was located in .\PCTEST directory has been removed
to reduce the size of Compressed Data File.
DOS Extender:
-------------
+ Bug fixed in DPMI function 0500h when the reported information was written
to DS instead of ES selector (I know, I know...).
+ The DOS Extender will now correctly recognize and execute all types of
DOS/4G(W) Professional bound applications.
+ Mode switching routines have been optimized for Pentium MMX/II and AMD K6
processors (or any CPU with multiple execution units supporting RISC86).
This does not really improve mode switching speed though.
+ Bug fixed: the DOS Extender can now display decimal numbers greater than
0x7FFF within strings containing "%d" option.
+ DOS/32 Advanced now supports the "Verbose Mode". This one can be useful when
you need to know exactly what is going on while the DOS Extender is loading
your application, amount of allocated memory and so on.
+ New environment option: /VERBOSE[:ON|OFF]. Refer to the "User's Reference"
("user_ref.doc" file) documentation for more information.
+ New "undocumented" DOS API function AX=Magic. This function is mentioned
somewhere in this package, but you will have to discover it yourself!
SUNSYS Setup Utility:
---------------------
+ The Setup Utility now supports new option: "Verbose Mode".
SUNSYS Bind Utility:
--------------------
+ The Bind Utility will now correctly recognize and process all types of
DOS/4G(W) Professional bound applications.
+ Two new commands: "-BS", bind STUB/32A to a file, and "-RS" replace existing
stub with STUB/32A, now supported.
SUNSYS Debugger:
----------------
+ The Debugger will now correctly recognize and load all types of
DOS/4G(W) Professional bound applications.
+ The Debugger shipped with the Free Package version of the DOS Extender now
supports all commands except "Here" (F4-key) and "Run" (F9-key).
*******************************************************************************
Release 3
DOS/32 Advanced DOS Extender version 4.00
=========================================
News:
-----
+ Installation program that installs DOS/32 Advanced DOS Extender on your
computer.
+ New stub file, 538 bytes in size!
DOS Extender:
-------------
+ DOS/32 Advanced DOS Extender does not check for 8086 anymore. This should not
be a problem since PC/XTs are quite dead nowdays.
+ DOS API function AH=0Ah is no longer supported and has been removed. It is
not used in WATCOM libraries and nobody uses it anyway.
+ Support for Slow Object Loading Scheme has been dropped. The DOS Extender
now requires some Extended memory in order to load application fixups, even
if the application itself is loaded in DOS memory.
+ Error code (4004) has been changed: not enough extended memory to load
application fixups.
+ Page Offset Shifts other than 0 are now supported by the loader for LX-style
executables.
+ Fixed bug in startup code causing no errors being reported when protected
mode was not entered successfully.
+ Fixed bug in exteded VBE API AX=4F00h when the CX register was not passed
down to the real mode.
+ VBE API is now truly extended: function AX=4F00h now translates the pointers
returned in the VBE structure to protected mode values.
+ New extended VBE functions have been added: AX=4F09h and AX=4F0Ah.
+ Bug fixed: options /QUIET and /PRINT:OFF defined in the environment now
disable the copyright string (Pro version only) as well as warnings.
+ Bug fixed: on exit under "Clean" system the DOS Extender will not disable
the A20 gate. This will solve problems when spawning programs with no
memory manager installed, but this will also produce a problem with A20 line
enabled after you run DOS/32 Advanced under "Clean" system. I guess we will
have to live with that, since there ain't many programs that rely on memory
wraparound under 1MB today, and you probably use a memory manager anyway.
+ Fixed a little bug in DPMI API function AX=0300h when parameters pushed on
stack that were to be copied to the real mode stack were not being copied
properly.
+ Bug fixed: extended DOS function AH=34h, get InDOS flag, will now work as
expected (no GPEs or crashes no more).
+ Bug fixed: the loader was not able to correctly load the last object of the
protected mode application, especially when the application was linked with
debug info which was placed directly after the last object's data. An
incorrect amount of bytes was read causing the _BSS segment being trashed
while it should contain zeroes only (by default, WATCOM startup code will
clear only the first 4K of _BSS segment if it thinks it runs under DOS/4GW).
+ Extended DOS API function AH=4Ch (terminate program), now will not restore
real mode environment segment in PSP at offset 002Ch to be compatible with
external DPMIs since they might need the protected mode selector at that
offset to perform their cleanup on the way to DOS,.. or some place else.
+ Extended DOS API now supports new functions: AX=0FF8Ah, AX=0FF90h, AX=0FF91h,
... and so on (see "prog_ref.doc" file).
SUNSYS Setup Utility:
---------------------
+ Option Use Fast Loading Object Scheme is no longer supported.
SUNSYS Bind Utility:
--------------------
+ No major changes.
SUNSYS Debugger:
----------------
+ No major changes.
*******************************************************************************
Release 2
DOS/32 Advanced DOS Extender version 3.00
=========================================
DOS Extender:
-------------
+ When a file name is specified at the command line, the DOS Extender will now
apply an ".exe" extension to it, if it could not open the original file. This
will solve some compatibility problems when replacing DOS/4GW DOS Extenders
with DOS/32 Advanced.
+ The loader now supports Fast Object Loading Scheme. This feature allows the
DOS Extender to load protected mode applications much faster (as fast as
DOS/4GW does). Though it requires some extended memory to be allocated. Note
that if no extended memory was allocated by the DOS Extender at startup,
this feature will not be used, and the DOS Extender will automatically use
the old, slow Object Loading Scheme, rather than reporting an error.
+ The loader now supports Paragraph (16 byte) alignment along with Page
alignment (4096 byte) for objects that are loaded into extended memory.
If a program has a large number of objects, this feature will greatly
increase the amount of free extended memory available after the application
was loaded.
+ Invented new DOS function in the DOS Extender: AX=0FF89h - DOS/32 Advanced
Get Configuration Info (see "prog_ref.doc" file).
+ Invented new DPMI API function (AX=0A00h): AL=06h - Get DOS/32 Advanced
Kernel Selectors (see "prog_ref.doc" file).
+ When spawning DOS/32 Advanced from another (incompatible) DOS Extender
under VCPI, DOS/32 Advanced startup code will no longer cause the system
to crash.
+ DPMI function 0500h will no longer return error 8013h when no extended
memory was allocated at startup. Instead it will simply fill all the
fields in the structure with zeroes.
+ DPMI function 0500h will no longer return the incorrect size of the largest
available extended memory block as it did before in rare cases.
SUNSYS Setup Utility:
---------------------
+ Option Console Output has been replaced with two new options: Show Warnings
and Show Copyright Banner at Startup.
+ New option in DOS Extender Configuration window: Use Fast Loading Object
Scheme.
+ New option in DOS Extender Configuration window: Object Alignment when
Loaded High.
+ New option in DOS Extender Configuration window: Show Copyright Banner at
Startup. This function replaces the old Console Output option, and allows
the user to separately disable warnings (with Show Warnings option) and
the copyright banner.
SUNSYS Debugger:
----------------
+ The Debugger now supports WATCOM-style assembly text screen along with
Borland's Turbo Debugger-style. Use key '1' to switch between TD and WD
text screens.
*******************************************************************************
Release 1
DOS/32 Advanced DOS Extender version 2.25
=========================================
+ The first publicly available version of DOS/32 Advanced DOS Extender.