Custom Home Assistant (HA) integration for Unipi devices. In my home assistant project I use Neron type of products but the component should work as well with other products (Axon, Patron, Lite) where Evok API can be run.

The system connect to the Unipi device via websocket (part of a separate python package wrapper). This bidirectional management connection enables a blazingly fast user experience and although Neuron devices supports directSwitch functionality (I do use it for light switches), you will most probably not see any difference between it or if you let HA do the desired action. Latency between an input signal change and action executed by HA is very low.

I was planning (this is still on my whish list) to integrate the component directly into home-assistant repo but to get things available for others to use, play around and extend, I decided to just release it as a barebone repo for now.

Installation

  1. Make sure that EVOK is installed and running on your Unipi devices.

  2. Configure Unipi device I/Os.

  3. Simply copy the custom_components folder to your own Home Assistant /config folder.

  4. Change you configuration yaml file with desired configuration.

Supported features

Functionality wise, it supports bare minimum (multiple device instances, lights, binary sensors and covers) so that my home-assistant project works.

TODO

There are tons of things that ar missing or could be added. Part of my backlog items are: support for MODBUS, 1-Wire sensors, automatic Neuron configuration, etc.

Configuration

Example of Basic config for three Unipi Neuron devices.
type parameter is not used for any specific purpose but one should set it to either "L203", "M203" or "S203". Other parameters should be self explanatory.

#Unipi neuron
unipi_neuron:
  - name: "device1"
    type: L203
    ip_address: 192.168.11.23
    reconnect_time: 30
  - name: "device2"
    type: M203
    ip_address: 192.168.11.21
    reconnect_time: 30
  - name: "device3"
    type: L203
    ip_address: 192.168.11.24
    reconnect_time: 30

Light component

Two modes are supported:
"on_off" - simple on or off type of outputs.
"pwm" - PWM type dimming (available only on digital output pins).

Port names are the same as defined in Evok API.

Note: Behavior of Unipi I/O's is configured on the Unipi device itself. So if if PWM mode is used by HA, then target output pin on Unipi must be configured accordingly.

#configuration.yaml
light:
  - platform: unipi_neuron
    device_id: "device1"
    devices:
      - name: "Light bathroom"
        device: relay
        mode: "on_off"
        port: "1_01"
      - name: "Light bedroom"
        device: relay
        mode: "on_off"
        port: "3_06"
  - platform: unipi_neuron
    device_id: "device2"
    devices:
      - name: "Light kitchen"
        device: relay
        mode: "on_off"
        port: "1_01"
      - name: "Light staircase"
        device: relay
        mode: "pwm"
        port: "1_02"

Binary sensor component

Port names are the same as defined in Evok API

#configuration.yaml
binary_sensor:
  - platform: unipi_neuron
    device_id: "device3"
    devices:
      - name: switch_up_utility
        device: input
        port: "2_01"
      - name: switch_down_utility
        device: input
        port: "2_08"
      - name: switch_light_toilet
        device: input
        port: "2_02"

Cover component

Used to manage dummy cover/blinds that only support driving motor up and down ( without any ability or sensor to detect location of the blinds or tilt)

Warning: Based on the cover supplier documentation, driving both signals up and down at the same time my damage the motor. Well in fact this happened to me once but it was not the motor that burned, it was relay outputs on my Unipi! Anyhow I have added a couple of check in the code to prevent such situation but there may still be corner cases that are not fully covered - so use it with caution :). Use this software at your own risk! I do not take responsibility in any way.

port_up and port_down are output ports used to drive blinds up and down.
full_close_time and full_open_time define the time it takes for blind to fully open (from closed state) or fully close (from open state) in seconds.
tilt_change_time defines time (in seconds) that the tilt changes from fully open to fully closed state (and vice-versa)
min_reverse_dir_time minimum time between changing the direction of the motor (in seconds) - defined by blind motor supplier.

#configuration.yaml
cover:
  - platform: unipi_neuron
    device_id: "main_level_1"
    covers:
      cover_utility:
        device: relay
        port_up: "2_01"
        port_down: "2_08"
        full_close_time: 40
        full_open_time: 40
        tilt_change_time: 1.5
        min_reverse_dir_time: 1
        name: "Cover_utility"
        device_class: "blind"
        friendly_name: "Cover Utility"
      cover_bedroom:
        device: relay
        port_up: "2_06"
        port_down: "2_07"
        full_close_time: 40
        full_open_time: 40
        tilt_change_time: 1.5
        min_reverse_dir_time: 1
        name: "Cover_bedroom"
        device_class: "blind"
        friendly_name: "Cover Bedroom"