Adding new SKU Mellanox-SN4600C-C4 #14
base: master
Are you sure you want to change the base?
Conversation
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Please provide more details of the SKU definition in the description:
buffer model: dynamic/static, shared headroom yes/no. Based on that please ask Stephen to review and approve.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Note: please check it can be cleanly cherry picked to 202012 and if so, add a comment to add it to it as well
Suggest adding the SKU port info like this:
You can refer PR 7337 regarding the description. |
The buffer pool sizes and SHP sizes are correct. |
In master branch hwsku.json file exists in the SKU folder, but in 202012 branch the file does not exist, so it can not be cherry picked. A new PR for 202012 branch has to be created. I will do it, once master branch, merge happens. |
Addressed it. |
Addressed it. |
@liat-grozovik can I take it for approved internally and raise a PR against Azure master? Please let me know. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Approve the buffer configuration.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Originally, I focused on the numbers when I was reviewing this PR and didn't realize there are errors in micro names.
@madhanmellanox please adjust it according to my suggestion and open a new PR.
Sorry for the inconvenient
@@ -0,0 +1,112 @@ | |||
{% set default_cable = '5m' %} | |||
{% set ingress_lossless_pool_size = '53379072' %} | |||
{% set ingress_lossy_pool_size = '1540096' %} |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
{% set ingress_lossy_pool_size = '1540096' %} | |
{% set ingress_lossless_xoff_size = '1540096' %} |
"BUFFER_POOL": { | ||
"ingress_lossless_pool": { | ||
{%- if dynamic_mode is not defined %} | ||
"size": "{{ ingress_lossless_pool_size }}", |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
"size": "{{ ingress_lossless_pool_size }}", | |
"size": "{{ ingress_lossless_pool_size }}", | |
"xoff": "{{ ingress_lossless_xoff_size }}", |
"BUFFER_POOL": { | ||
"ingress_lossless_pool": { | ||
{%- if dynamic_mode is not defined %} | ||
"size": "{{ ingress_lossless_pool_size }}", |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
"size": "{{ ingress_lossless_pool_size }}", | |
"size": "{{ ingress_lossless_pool_size }}", | |
"xoff": "{{ ingress_lossless_xoff_size }}", |
"type": "ingress", | ||
"mode": "dynamic" | ||
}, | ||
"ingress_lossy_pool": { |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
ingress_lossy_pool
section should be removed
"dynamic_th":"7" | ||
}, | ||
"ingress_lossy_profile": { | ||
"pool":"[BUFFER_POOL|ingress_lossy_pool]", |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
"pool":"[BUFFER_POOL|ingress_lossy_pool]", | |
"pool":"[BUFFER_POOL|ingress_lossless_pool]", |
"BUFFER_PORT_INGRESS_PROFILE_LIST": { | ||
{% for port in port_names.split(',') %} | ||
"{{ port }}": { | ||
"profile_list" : "[BUFFER_PROFILE|ingress_lossless_profile],[BUFFER_PROFILE|ingress_lossy_profile]" |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
"profile_list" : "[BUFFER_PROFILE|ingress_lossless_profile],[BUFFER_PROFILE|ingress_lossy_profile]" | |
"profile_list" : "[BUFFER_PROFILE|ingress_lossless_profile]" |
"BUFFER_POOL": { | ||
"ingress_lossless_pool": { | ||
{%- if dynamic_mode is not defined %} | ||
"size": "{{ ingress_lossless_pool_size }}", |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
"size": "{{ ingress_lossless_pool_size }}", | |
"size": "{{ ingress_lossless_pool_size }}", | |
"xoff": "{{ ingress_lossless_pool_xoff }}", |
"type": "ingress", | ||
"mode": "dynamic" | ||
}, | ||
"ingress_lossy_pool": { |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
ingress_lossy_pool
section should be removed
"BUFFER_PORT_INGRESS_PROFILE_LIST": { | ||
{% for port in port_names.split(',') %} | ||
"{{ port }}": { | ||
"profile_list" : "[BUFFER_PROFILE|ingress_lossless_profile],[BUFFER_PROFILE|ingress_lossy_profile]" |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
"profile_list" : "[BUFFER_PROFILE|ingress_lossless_profile],[BUFFER_PROFILE|ingress_lossy_profile]" | |
"profile_list" : "[BUFFER_PROFILE|ingress_lossless_profile]" |
Why I did it
I did it to add a new SKU Mellanox-SN4600c-c64
How I did it
I developed the SKU based on SKU definitions with the following requirements and tested it on Mellanox 4600C switch.
Port configuration:
• Breakout mode for each port: No
• Speed of the port: 100G
• Auto-negotiation enable/disable: No setting required
• FEC mode: No setting required
• Type of transceiver used: Not needed
Buffer configuration
• Shared headroom enable
• If shared headroom enabled what is the over-subscription ratio as in SN3800
• Dynamic Buffer disable
• In static buffer scenario how many uplinks and downlinks? as in SN3800
• 2km cable support required? no
Switch configuration
• Warmboot enabled? yes
• Should warmboot be added to SAI profile when enabled? yes
• Is VxLAN source port range set? yes
• Should Vxlan source port range be added to SAI profile when set. as in SN3800
• Is Static Policy Based Hashing enabled? no
Number of Uplinks/Downlinks:
How to verify it
Set the SKU in config_db.json to Mellanox-SN4600C-C64 and test the 100G ports coming up on the switch.
Which release branch to backport (provide reason below if selected)
Description for the changelog
Changes are in sonic-buildimage/device/mellanox/x86_64-mlnx_msn4600c-r0/Mellanox-SN4600C-C64/ folder.