Description of MG/SP Events
Table 12: List of events for MG/SP control panels
Event Group Event Group Description Sub-group Sub-group Description
00 Zone OK 01 to 32 Zone number
01 Zone open 99 Any zone number
02 Partition status 00 to 01 -
02 Silent alarm
03 Buzzer alarm
04 Steady alarm
05 Pulsed alarm
06 Strobe
07 Alarm stopped
08 Squawk ON (partition 1only)
09 Squawk OFF (partition 1 only)
10 Ground start (partition 1 only)
11 Disarm partition
12 Arm partition
13 Entry delay started
14 Exit delay started
15 Pre-alarm delay
16 Report confirmation
99 Any partition status event
03 Bell status (partition 1 only) 00 Bell OFF
01 Bell ON
02 Bell squawk arm
03 Bell squawk disarm
99 Any bell status event
06 Non-reportable event 00 Telephone line trouble
01 CLEAR + ENTER, or was pressed for 3 secs. (partition 1 only)
02 -
03 Arm in Stay mode
04 Arm in Sleep mode
05 Arm in Force mode
06 Full arm when armed in Stay mode
07 PC fail to communicate (partition 1 only)
08 Utility key 1 pressed (keys 1 and 2; partition 1 only)
09 Utility key 2 pressed (keys 4 and 5; partition 1 only)
10 Utility key 3 pressed (keys 7 and 8; partition 1 only)
11 Utility key 4 pressed (keys 2 and 3; partition 1 only)
12 Utility key 5 pressed (keys 5 and 6; partition 1 only)
13 Utility key 6 pressed (keys 8 and 9; partition 1 only)
14 Tamper generated alarm
15 Supervision loss generated alarm
16 -
17 -
18 -
19 -
20 Full arm when armed in Sleep mode
21 Firmware upgrade (partition 1 only; non-PGM event)
22 -
23 StayD mode activated
24 StayD mode deactivated

Event Group Event Group Description Sub-group Sub-group Description
06
(Cont.) Non-reportable event (Cont.) 25 IP registration status change
26 GPRS registration status change
27 Armed with trouble(s)
28 Supervision alert
29 Supervision alert restore
30 Armed with remote with low battery
99 Any non-reportable event
08 Button pressed on remote (see Default Data B, in worksheet 26 on page 35) 01 to 32 Remote control number
99 Any remote control number
09 Button pressed on remote (see Default Data C, in worksheet 26 on page 35) 01 to 32 Remote control number
99 Any remote control number
10 Button pressed on remote (see Default Data D, in worksheet 26 on page 35) 01 to 32 Remote control number
99 Any remote control number
11 Button pressed on remote (see Default Data E, in worksheet 26 on page 35) 01 to 32 Remote control number
99 Any remote control number
12 Cold start wireless zone 01 to 32 Zone number
99 Any zone number
13 Cold start wireless module (partition 1 only) 01 to 16 Output number
17 to 18 Wireless repeater
19 to 26 Wireless keypad
27 to 30 Wireless siren
99 Any output number
14 Bypass programming 01 to 32 User number
99 Any user number
15 User code activated output (partition 1 only) 01 to 32 User number
99 Any user number
16 Wireless smoke maintenance signal 01 to 32 Zone number
99 Any zone number
17 Delay zone alarm transmission 01 to 32 Zone number
99 Any zone number
18 Zone signal strength weak 1 (partition 1 only) 01 to 32 Zone number
99 Any zone number
19 Zone signal strength weak 2 (partition 1 only) 01 to 32 Zone number
99 Any zone number
20 Zone signal strength weak 3 (partition 1 only) 01 to 32 Zone number
99 Any zone number
21 Zone signal strength weak 4 (partition 1 only) 01 to 32 Zone number
99 Any zone number
22 Button pressed on remote (see option 5, in table 22 on page 34) 01 to 32 Remote control number
99 Any remote control number
23 Button pressed on remote (see option 6, in table 22 on page 34) 01 to 32 Remote control number
99 Any remote control number
24 Fire delay started 01 to 32 Zone number
99 Any zone number

Event Group Event Group Description Sub-group Sub-group Description
25 - - -
26 Software access (VDMP3, IP100, WinLoad, BabyWare) 00 Non-valid source ID
01 WinLoad/BabyWare direct
02 WinLoad/BabyWare through IP module
03 WinLoad/BabyWare through GSM module
04 WinLoad/BabyWare through modem
09 IP100 direct
10 VDMP3 direct
11 Voice through GSM module
12 Remote access
13 SMS through GSM module
99 Any software access
27 Bus module event 00 A bus module was added
01 A bus module was removed
02 2-way RF module communication failure
03 2-way RF module communication restored
99 Any bus module event
28 StayD pass acknowledged 01 to 32 Zone number
99 Any zone number
29 Arming with user 01 to 32 User number
99 Any user number
30 Special arming 00 Auto-arming (on-time/no movement)
01 Late to close
02 No movement arming
03 Partial arming
04 Quick arming
05 Arming through WinLoad/BabyWare
06 Arming with keyswitch
99 Any special arming
31 Disarming with user 01 to 32 User number
99 Any user number
32 Disarming after an alarm with user 01 to 32 User number
99 Any user number
33 Alarm cancelled with user 01 to 32 User number
99 Any user number
34 Special disarming 00 Auto-arm cancelled (on-time/no movement)
01 Disarming through WinLoad/BabyWare
02 Disarming through WinLoad/BabyWare after alarm
03 Alarm cancelled through WinLoad/BabyWare
04 Paramedical alarm cancelled
05 Disarm with keyswitch
06 Disarm with keyswitch after an alarm
07 Alarm cancelled with keyswitch
99 Any special disarming
35 Zone bypassed 01 to 32 Zone number
99 Any zone number
36 Zone in alarm 01 to 32 Zone number
99 Any zone number
37 Fire alarm 01 to 32 Zone number
99 Any zone number

Event Group Event Group Description Sub-group Sub-group Description
38 Zone alarm restore 01 to 32 Zone number
99 Any zone number
39 Fire alarm restore 01 to 32 Zone number
99 Any zone number
40 Special alarm 00 Panic non-medical emergency
01 Panic medical (this panic alarm in not UL approved)
02 Panic fire
03 Recent closing
04 Global shutdown
05 Duress alarm
06 Keypad lockout (partition 1 only)
99 Any special alarm event
41 Zone shutdown 01 to 32 Zone number
99 Any zone number
42 Zone tampered 01 to 32 Zone number
99 Any zone number
43 Zone tamper restore 01 to 32 Zone number
99 Any zone number


Event Group Event Group Description Sub-group Sub-group Description
44 New trouble (partition 1 only, except sub-group 07, which is for both partitions) 00 -
01 AC failure
02 Battery failure
03 Auxiliary current overload
04 Bell current overload
05 Bell disconnected
06 Clock loss
07 Fire loop trouble
08 Fail to communicate with monitoring station telephone # 1
09 Fail to communicate with monitoring station telephone # 2
11 Fail to communicate with voice report
12 RF jamming
13 GSM RF jamming
14 GSM no service
15 GSM supervision lost
16 Fail to communicate IP receiver 1 (GPRS)
17 Fail to communicate IP receiver 2 (GPRS)
18 IP module no service
19 IP module supervision loss
20 Fail to communicate IP receiver 1 (IP)
21 Fail to communicate IP receiver 2 (IP)
22 GSM/GPRS module tamper trouble
99 Any new trouble event
45 Trouble restored 00 Telephone line restored
01 AC failure restore
02 Battery failure restore
03 Auxiliary current overload
04 Bell current overload restore
05 Bell disconnected restore
06 Clock loss restore
07 Fire loop trouble restore
08 Fail to communicate with monitoring station tel. # 1 restore
09 Fail to communicate with monitoring station tel. # 2 restore
11 Fail to communicate with voice report restore
12 RF jamming restore
13 GMS RF jamming restore
14 GSM no service restore
15 GSM supervision lost restore
16 Fail to communicate restore IP receiver 1 (GPRS)
17 Fail to communicate restore IP receiver 2 (GPRS)
18 IP module no service restore
19 IP module supervision loss restore
20 Fail to communicate restore IP receiver 1 (IP)
21 Fail to communicate restore IP receiver 2 (IP)
22 GSM/GPRS module tamper trouble restore
99 Any new trouble restored event

Event Group Event Group Description Sub-group Sub-group Description
46 Bus/EBus/wireless module new trouble (partition 1 only) 00 Bus/EBus/wireless module communication fault
01 Tamper trouble
02 Power fail
03 Battery failure
99 Any bus module new trouble event
47 Bus/EBus/wireless module trouble restored (partition 1 only) 00 Bus/EBus/wireless module communication fault restore
01 Tamper trouble restore
02 Power fail restore
03 Battery failure restore
99 Any bus module new trouble restored event
48 Special (partition1 only) 00 System power up
01 Reporting test
02 Software log on
03 Software log off
04 Installer in programming mode
05 Installer exited programming mode
06 Maintenance in programming mode
07 Maintenance exited programming mode
08 Closing delinquency delay elapsed
13 Failed to arm
99 Any special event
49 Low battery on zone 01 to 32 Zone number
99 Any zone number
50 Low battery on zone restore 01 to 32 Zone number
99 Any zone number
51 Zone supervision trouble 01 to 32 Zone number
99 Any zone number
52 Zone supervision restore 01 to 32 Zone number
99 Any zone number
53 Wireless module supervision trouble (partition 1 only) 01 to 16 Output
17 to 18 Wireless repeater
19 to 22 Wireless keypad
27 to 30 Wireless siren
99 Any output number
54 Wireless module supervision restore (partition 1 only) 01 to 16 Output
17 to 18 Wireless repeater
19 to 22 Wireless keypad
27 to 30 Wireless siren
99 Any output number
55 Wireless module tamper trouble (partition 1 only) 01 to 16 Output
17 to 18 Wireless repeater
19 to 22 Wireless keypad
27 to 30 Wireless siren
99 Any output number
56 Wireless module tamper restore (partition 1 only) 01 to 16 Output
17 to 18 Wireless repeater
19 to 22 Wireless keypad
27 to 30 Wireless siren
99 Any output number
Event Group Event Group Description Sub-group Sub-group Description
57 Non-medical alarm (paramedic) 01 to 32 User number
99 Any user number
58 Zone forced 01 to 32 Zone number
99 Any zone number
59 Zone included 01 to 32 Zone number
Zone included (Cont.) 99 Any zone number
60 Remote low battery 01 to 32 User number
99 Any user number
61 Remote low battery restore 01 to 32 User number
99 Any user number
64 System status (on-board PGMs only) 00 Follow ARM LED status*:
PGM pulse fast in alarm
PGM pulse fast in exit delay, below 10 sec.
PGM pulse slow in exit delay, over 10 sec.
PGM steady ON, if armed
PGM OFF, if disarmed
* This event can be assigned to partition 1 or 2. If assigned to both partitions, the PGM event will follow the list order above, with number 1 being the highest priority.