Original file line number Diff line number Diff line change
Expand Up @@ -41,12 +41,18 @@ zone=""
zoneSpecified=false
argSTART=4
logErrors=true
noSensors=false
noSensors=true
fanSpeed=false
fspeed="low"
# By default selfTest is off
selfTest="TEST_OFF"

# Define some variables for zone open checking
zoneArray=(z01 z02 z03 z04 z05 z06 z07 z08 z09 z10)
zoneOpen=0

# For timer capability
timerEnabled=false

function showHelp()
{
Expand All @@ -61,8 +67,8 @@ function showHelp()
Where Options maybe any of the following in any order:
z01, z02, z03 ... The zone to Set or Query
XXX.XXX.XXX.XXX The IP address of the AirCon to talk to
noSensors If you do not have any sensors
fanSpeed If the accessory is used to control the fan speed
timer To use a Lightbulb accessory as a timer
Additional test options to the above are:
TEST_OFF The default
Expand Down Expand Up @@ -156,6 +162,11 @@ function parseMyAirDataWithJq()
jqResult=$(echo "$myAirData" | jq -e "$jqPath")
rc=$?
# Added to ensure that if "$jqResult = false", rc is set to 0 because $jqResult = false is an acceptable answer.
if [ $jqResult = false ]; then
rc=0
fi
if [ "$rc" != "0" ]; then
if [ "$exitOnFail" = "1" ]; then
# The result cannot be trusted with a bad return code
Expand Down Expand Up @@ -270,14 +281,16 @@ if [ $argEND -ge $argSTART ]; then
selfTest=${v}
optionUnderstood=true
;;
noSensors)
noSensors=true
optionUnderstood=true
;;
# If the accessory is used to control the fan speed
fanSpeed)
fanSpeed=true
optionUnderstood=true
;;
# Aded to include a timer capability
timer)
timerEnabled=true
optionUnderstood=true
;;
*)
#
# See if the option starts with a 'z' for zone
Expand Down Expand Up @@ -307,20 +320,41 @@ if [ $argEND -ge $argSTART ]; then
done
fi
# For "Get" Directives
if [ "$io" = "Get" ]; then
case "$characteristic" in
# Gets the current temperature.
CurrentTemperature )
if [ "$noSensors" = true ]; then
# Uses the set temperature as the measured temperature
# in lieu of having sensors.
queryAndParseAirCon "http://$IP:2025/getSystemData" '.aircons.ac1.info.setTemp'
else
# Updates global variable jqResult
# Added to determine whether Temperature Sensors are used in this system
queryAirCon "http://$IP:2025/getSystemData" "1" "0"
# Check if any zones have "rssi" value != 0 and != "null", if so, set noSensors=false
for (( a=0;a<=9;a++ ))
do
parseMyAirDataWithJq '.aircons.ac1.zones.'${zoneArray[a]}'.rssi'
if [ $jqResult != 0 ] && [ $jqResult != "null" ]; then
noSensors=false
break
fi
done
if [ "$noSensors" = false ] && [ $zoneSpecified = false ]; then
# Get the constant zone info from the system
parseMyAirDataWithJq '.aircons.ac1.info.constant1'
if [ $jqResult != 10 ];then
cZone="z0$jqResult"
else
cZone="z$jqResult"
fi
# Use constant zone for Thermostat temperature reading
queryAndParseAirCon "http://$IP:2025/getSystemData" '.aircons.ac1.zones.'"$cZone"'.measuredTemp'
elif [ $zoneSpecified = true ]; then
# Use zone for Temperature Sensor temp reading
queryAndParseAirCon "http://$IP:2025/getSystemData" '.aircons.ac1.zones.'"$zone"'.measuredTemp'
elif [ "$noSensors" = true ]; then
# Uses the set temperature as the measured temperature in lieu of having sensors.
queryAndParseAirCon "http://$IP:2025/getSystemData" '.aircons.ac1.info.setTemp'
fi
echo "$jqResult"
Expand Down Expand Up @@ -401,7 +435,7 @@ if [ "$io" = "Get" ]; then
;;
On )
if [ $zoneSpecified = false ] && [ $fanSpeed = false ]; then
if [ $zoneSpecified = false ] && [ $fanSpeed = false ] && [ $timerEnabled = false ]; then
# Return value of Off if the zone is closed or the Control Unit is Off.
# Updates global variable jqResult
queryAndParseAirCon "http://$IP:2025/getSystemData" '.aircons.ac1.info.state'
Expand Down Expand Up @@ -471,22 +505,67 @@ if [ "$io" = "Get" ]; then
exit 0
fi
# Added to get the timer current setting
elif [ $timerEnabled = true ]; then
queryAndParseAirCon "http://$IP:2025/getSystemData" '.aircons.ac1.info.state'
# If the aircon state is "off", set "countDownToOff" to 0
if [ "$jqResult" = '"off"' ]; then
parseMyAirDataWithJq '.aircons.ac1.info.countDownToOn'
queryAirCon "http://$IP:2025/setAircon?json={ac1:{info:{countDownToOff:0}}}" "1" "0"
# If "countDownToOn" is 0 then switch the timer off
if [ "$jqResult" = '0' ]; then
echo 0
exit 0
else
# If "countDownToOn" is not 0, switch on the timer
echo 1
exit 0
fi
else
# If the aircon state is "on", set "countDownToOn" to 0
parseMyAirDataWithJq '.aircons.ac1.info.countDownToOff'
queryAirCon "http://$IP:2025/setAircon?json={ac1:{info:{countDownToOn:0}}}" "1" "0"
if [ "$jqResult" = "0" ]; then
# If "countDownToOff" is 0 then switch the timer off
echo 0
exit 0
else
# If "contDownToOff" is not 0 then switch on the timer
echo 1
exit 0
fi
fi
elif [ $fanSpeed = true ]; then
# set the "Fan Speed" accessory to "on" at all time
# Set the "Fan Speed" accessory to "on" at all time
echo 1
exit 0
fi
;; # End of On
#Light Bulb service used for controlling damper % open
Brightness )
# Updates global variable jqResult
queryAndParseAirCon "http://$IP:2025/getSystemData" '.aircons.ac1.zones.'"$zone"'.value'
echo "$jqResult"
exit 0
# Gets the timer and zone damper % information
if [ $zoneSpecified = true ]; then
# Get the zone damper % open
queryAndParseAirCon "http://$IP:2025/getSystemData" '.aircons.ac1.zones.'"$zone"'.value'
echo "$jqResult"
exit 0
elif [ $timerEnabled = true ]; then
# Get the timer countdown value
queryAndParseAirCon "http://$IP:2025/getSystemData" '.aircons.ac1.info.state'
if [ "$jqResult" = '"on"' ]; then
parseMyAirDataWithJq '.aircons.ac1.info.countDownToOff'
echo $(expr $jqResult / 10)
exit 0
else
parseMyAirDataWithJq '.aircons.ac1.info.countDownToOn'
echo $(expr $jqResult / 10)
exit 0
fi
fi
;;
# Fan service for controlling fan speed (low, medium and high)
Expand Down Expand Up @@ -563,7 +642,22 @@ if [ "$io" = "Set" ]; then
;;
TargetTemperature )
if [ "$noSensors" = true ]; then
# Added to determine whether Temperature Senors are used in this system
queryAirCon "http://$IP:2025/getSystemData" "1" "0"
# Check if any zones have "rssi" value != 0 and != "null", if so, set noSensors=false
for (( a=0;a<=9;a++ ))
do
parseMyAirDataWithJq '.aircons.ac1.zones.'${zoneArray[a]}'.rssi'
if [ $jqResult != 0 ] && [ $jqResult != "null" ]; then
noSensors=false
break
fi
done
if [ $noSensors = true ]; then
# Only sets temperature to master temperature in the app
queryAirCon "http://$IP:2025/setAircon?json={ac1:{info:{setTemp:$value}}}" "1" "0"
exit 0
Expand All @@ -576,7 +670,7 @@ if [ "$io" = "Set" ]; then
On )
# Uses the On characteristic for Fan/Vent mode.
if [ $zoneSpecified = false ] && [ $fanSpeed = false ]; then
if [ $zoneSpecified = false ] && [ $fanSpeed = false ] && [ $timerEnabled = false ]; then
if [ "$value" = "1" ]; then
# Sets Control Unit to On, sets to Fan mode aqnd fan speed will default to last used.
queryAirCon "http://$IP:2025/setAircon?json={ac1:{info:{state:on,mode:vent}}}" "1" "0"
Expand All @@ -595,25 +689,89 @@ if [ "$io" = "Set" ]; then
exit 0
else
queryAirCon "http://$IP:2025/setAircon?json={ac1:{zones:{$zone:{state:close}}}}" "1" "0"
# Ensures that at least one zone is open at all time to protect the aircon system before closing any zone:
# > if the only zone open is the constant zone, leave it open and set it to 100%.
# > if the constant zone is already closed, and the only open zone is set to close,
# the constant zone will open and set to 100% while closing that zone.
queryAirCon "http://$IP:2025/getSystemData" "1" "0"
# Get the constant zone info from the system
parseMyAirDataWithJq '.aircons.ac1.info.constant1'
if [ $jqResult != 10 ];then
cZone="z0$jqResult"
else
cZone="z$jqResult"
fi
# Check how many zones are open
for (( a=0;a<=9;a++ ))
do
parseMyAirDataWithJq '.aircons.ac1.zones.'${zoneArray[a]}'.state'
if [ "$jqResult" = '"open"' ]; then
zoneOpen=$(expr $zoneOpen + 1)
fi
done
if [ $zoneOpen -gt 1 ]; then
# If there are more than 1 zone open, it is safe to close this zone.
queryAirCon "http://$IP:2025/setAircon?json={ac1:{zones:{$zone:{state:close}}}}" "1" "0"
exit 0
elif [ $zone = $cZone ]; then
# If only 1 zone open and is the constant zone. do not close but set to 100%
queryAirCon "http://$IP:2025/setAircon?json={ac1:{zones:{$zone:{value:100}}}}" "1" "0"
exit 0
else
# If only 1 zone open and is not the constant zone, open the constant zone and close this zone
queryAirCon "http://$IP:2025/setAircon?json={ac1:{zones:{$cZone:{state:open},$zone:{state:close}}}}" "1" "0"
sleep 0.5
# Set the constant zone to 100%
queryAirCon "http://$IP:2025/setAircon?json={ac1:{zones:{$cZone:{value:100}}}}" "1" "0"
exit 0
fi
fi
# Added to include the timer capability
elif [ $timerEnabled = true ]; then
if [ "$value" = "0" ]; then
# Set both "countDownToOn" and "countDownToOff" to 0, otherwise do nothing
queryAirCon "http://$IP:2025/setAircon?json={ac1:{info:{countDownToOn:0}}}" "1" "0"
queryAirCon "http://$IP:2025/setAircon?json={ac1:{info:{countDownToOff:0}}}" "1" "0"
exit 0
else
# Do nothing
exit 0
fi
elif [ $fanSpeed = true ]; then
# No real on/off function but issue "exit 0" to let cmd4 know that action is satisfied
exit 0
fi
;;
#Light Bulb service for used controlling damper % open
#Light Bulb service for used controlling damper % open and timer
Brightness )
#round the $value to its nearst 5%
damper=$(expr $(expr $(expr $value + 2) / 5) \* 5)
# Modified to include the conditional statements for damper %
if [ $zoneSpecified = true ]; then
# Round the $value to its nearst 5%
damper=$(expr $(expr $(expr $value + 2) / 5) \* 5)
queryAirCon "http://$IP:2025/setAircon?json={ac1:{zones:{$zone:{value:$damper}}}}" "1" "0"
exit 0
queryAirCon "http://$IP:2025/setAircon?json={ac1:{zones:{$zone:{value:$damper}}}}" "1" "0"
exit 0
# Added to include the timer capability
elif [ $timerEnabled = true ]; then
# Make 1% to 10 minutes and capped at a max of 720 minutes
timerInMinutes=$(expr $value \* 10)
timerInMinutes=$(($timerInMinutes < 720? $timerInMinutes : 720))
queryAndParseAirCon "http://$IP:2025/getSystemData" '.aircons.ac1.info.state'
if [ "$jqResult" = '"on"' ]; then
queryAirCon "http://$IP:2025/setAircon?json={ac1:{info:{countDownToOff:$timerInMinutes}}}" "1" "0"
exit 0
else
queryAirCon "http://$IP:2025/setAircon?json={ac1:{info:{countDownToOn:$timerInMinutes}}}" "1" "0"
exit 0
fi
fi
;;
# Fan service for controlling fan speed (0-33%:low, 34-67%:medium, 68-99%:high, 100%:autoAA/auto)
Expand Down
24 changes: 24 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,30 @@

All notable changes to this project will be documented in this file. This project uses [Semantic Versioning](https://semver.org/).

## 3.2.0 (2022-02-04)

Special thanks to the amazing [uswong](https://github.com/uswong) for adding these new features! Thank you to all who participated in the beta testing!

### Notable Changes

* Zone closing check to ensure that at least one zone is open at all times as a secondary layer of protection for your ducting.
* If you close all zones, it will open your Constant Zone damper to 100%.
* No longer require the use of `noSensors` in your `config.json`. The script determines if you have sensors or not.
* Temperature Sensor users no longer require to add zone (`z01`, `z02`, etc.) to `"state_cmd_suffix"` of Thermostat in your `config.json`. The script determines and sets it as your Constant Zone.
* You can still set a zone if you prefer to choose a different zone to your Constant Zone.
* Countdown timer added as a Lightbulb accessory; config can be found [here](https://github.com/mitch7391/homebridge-cmd4-AdvantageAir/wiki/Config-Creation#timer).
* Depending on if your Advantage Air system is on or off will determine if the countdown is to turn the system on or off when it reaches 0.
* New constant `timer` will need to be added to the `"state_cmd_suffix"` of this accessory.
* The Advantage Air system will only allow 720 minutes (12 hours) for a timer and the Lightbulb has 0-100% to utilise.
* Therefore, setting 1% will equal 10 minutes, 6% will be equal to 1 hour.
* Setting a value higher than 72% (720 minutes), will default back to 72% on the Lightbulb.

### Other Changes

* Shell Check Tool updated for new configurations. Always check you `config.json` with this after making changes!
* Dev dependancy `nanoid` security update to `v3.1.31`.


## 3.1.0 (2022-01-18)

Special thanks to the amazing [uswong](https://github.com/uswong) for adding the new fan speed feature and fixing the zone percentage bug! Thank you to all who participated in the beta testing!
Expand Down
2 changes: 1 addition & 1 deletion Config_Samples/ConfigSample_NoSensors.json
Original file line number Diff line number Diff line change
Expand Up @@ -202,7 +202,7 @@
}
],
"state_cmd": "'/usr/local/lib/node_modules/homebridge-cmd4-advantageair/AdvAir.sh'",
"state_cmd_suffix": "${IP} noSensors",
"state_cmd_suffix": "${IP}",
"linkedTypes": [
{
"type": "Fan",
Expand Down
2 changes: 1 addition & 1 deletion Config_Samples/ConfigSample_Sensors.json
Original file line number Diff line number Diff line change
Expand Up @@ -285,7 +285,7 @@
}
],
"state_cmd": "'/usr/local/lib/node_modules/homebridge-cmd4-advantageair/AdvAir.sh'",
"state_cmd_suffix": "z01 ${IP}",
"state_cmd_suffix": "${IP}",
"linkedTypes": [
{
"type": "Fan",
Expand Down
2 changes: 1 addition & 1 deletion Config_Samples/ConfigSample_SomeSensors.json
Original file line number Diff line number Diff line change
Expand Up @@ -244,7 +244,7 @@
}
],
"state_cmd": "'/usr/local/lib/node_modules/homebridge-cmd4-advantageair/AdvAir.sh'",
"state_cmd_suffix": "z01 ${IP}",
"state_cmd_suffix": "${IP}",
"linkedTypes": [
{
"type": "Fan",
Expand Down
Loading

0 comments on commit e7f349a

Please sign in to comment.