Fatek PLC Binding

Slawomir Jaranowski edited this page Nov 11, 2016 · 1 revision

Introduction

Fatek PLC is one kind of programmable logic controller.
http://fatek.com/en/prod.php?catId=1

This binding support native Fatek protocol to communicate with PLC.
For communication to PLC is used JFatek library: http://www.simplify4u.org/jfatek/

For installation of the binding, please see Wiki page Bindings.

Setting Fatek PLC binding

There are some configuration that must be set in openhab.cfg file (conf/services/fatekplc.cfg for OH2). Below we have example:

################################### Fatek PLC Binding ###################################

# the refresh interval in milliseconds which is used to poll values from the Fatek PLC server
# (optional, defaults to 60000ms / 60 seconds)
fatekplc:refresh=5000

# fatek connection uri, support tcp and udp
fatekplc:plc1.connectionUri=udp://192.168.1.100?plcId=1

#########################################################################################

fatekplc is namespace used by binding.

We can configure connection to many Fatek PLC, each fatek has unique label, which is used by item configurations.

fatekplc:<plcName>.connectionUri=...

Items binding configurations

OpenHab items can be bound to Fatek PLC by example definition

Item ... { fatekplc="faatek_binding" }

"fatek binding" is described below for specific item type.

For all items we can add options refreshStep, eg.

plc1:R100:refreshStep=2

this means that item will be updated every second poll cycle.

Color item binding

plcName:REG1:REG2:REG3[:REG4][:RGB|HSB]

Last element indicate color mode used to write data to PLC, default value is HSB.

  • REG1, REG2 and RE3 must be data type register.
  • for HSB mode REG1 = H, REG2 = S, REG3 = B
  • for RGB mode REG1 = R, REG2 = G, REG3 = B

REG4 is optional if you specified it, on/off command will use that register for corresponding on/off state. If you not specified REG4 on/off command will write white or black value to color registers.

Contact item binding

plcName:[!]REG

We specified only one register. If register name starts with "!" (exclamation mark) value read will be inverted.

Switch items binding

plcName:[!]REG1[[!]REG2]
  • REG1 is used for read state of switch
  • REG2 is used for change state of switch, if is not specified - REG1 is used

If registers name starts with "!" (exclamation mark) value read and written will be inverted.

DateTime item

Version 1

plcName:Y:m:d:H:M:S

Where

  • Y - year reg, if value in range 0 - 49 we add 2000, in range 50 - 99 we add 1900
  • m - month reg - range 1 - 12, (1 means January)
  • d - day of the month reg - The first day of the month has value 1
  • H - hour of the day reg - 24-hour clock
  • M - minute reg
  • S - second reg

All fields must be set, if you want to skip some of the item you can put number instead of register name.

Item accept only 16 bit data register. You can end register name with L - lowest 8 bits or H - highest 8 bits.

Eg. read current PLC time

plcName:R4133:R4132:R4131:R4135H:R4135L:R4128

Version 2

plcName:REG[R][:factor=factorValue]

In REG we store seconds from begining of the UNIX epoch.

If we add R to the end of register name DateTime item will recognize as relative seconds to now. We can read some counter which count seconds and we can display the time when counting was started.

We can also specific factor value, read seconds will be multiplied by this value.

Dimmer item binding

plcName:REG:[step=value][:factor=factorValue]

We use one data type register for value.

Step options can specified step value for increase/decrease command.

We can also specific factor value, all read data will be multiplied by this value, before write value from OpenHab will be divided by factor.

Number item binding

plcName:[+]REG[F][:transformationType(params)][:factor=factorValue]

If we start register name with + (plus sign) values read from plc will be recognized as unsigned number.

If we end register name with "F" values read from plc will be recognized as float number. For float number 32 bits data register must be used.

We can also specific factor value, all read data will be multiplied by this value, before write value from OpenHab will be divided by factor.

For Number item we can provide transformation function, eg: JS(file.js)

Rollershutter item binding

plcName:REG1:REG2:REG3[:factor=factorValue]
  • REG1 is used for reading current positions in percent.
  • REG2 is set to true/1 for UP command
  • REG3 is set to true/1 for DOWN command
  • for STOP command REG2 and REG3 is set to false/0.

We can also specific factor value, all read data will be multiplied by this value.

String item

Not implemented

Installation


User Interfaces


Community

(link to openHAB forum)

Development



Misc


Samples

A good source of inspiration and tips from users gathered over the years. Be aware that things may have changed since they were written and some examples might not work correctly.

Please update the wiki if you do come across any out of date information.

Use case examples

Collections of Rules on a single page

Single Rules

Scripts


Release Notes

Clone this wiki locally